1-800-663-4209 | Welcome to our new website, found an issue or bug? Please report it here
CDTX-111-CDTX-112-Series
Panel Mount Conductivity and Temperature Monitor and Controller
Models In Stock
- On/Off Relay Outputs
- Economical
- Automatic or Manual Temperature Compensation
- Selectable Zero and Span Analog Output
CDTX-111-CDTX-112-Series
From
$
285.98
Models In Stock

Product Overview
- Accuracy ± 1 %
- Additional Features 1 1/4" DIN, Sensors Sold Separately
- Altitude,Max 3000 m
- Conductivity Measurement 0 to 999.9 μS/cm, 0 to 9999 μS/cm, 0 to 100mS/cm, 0 to 600 mS/cm
- Cutout Dimensions 92 × 92 mm
- Display Size 13 mm (0.51 in)
- Display Type LCD
- Enclosure Ratings IP54
- Frequency 50/60 Hz
- Height 96 mm
- Impedance 750 Ω
- Length 110 mm
- Mounting Orientation Panel Mount
- Number of Relays 2
- Operating Humidity 5 to 95% RH
- Operating Range Note Resistivity: 0 to 18 MΩ or 0 to 19.99 μS/cm
- Operating Temperature, Max 55 °C
- Operating Temperature, Min -10 °C
- Output Detail Type: Isolated 4 to 20 mA Range: Selectable zero and span Accuracy: ±0.02 mA
- Process Temperature, Max 0 °C
- Process Temperature, Min 100 °C
- Relay Note 2 programmable , 10 A Control Type: On/off Relay Set Point Hysteresis: User programmable
- Resolution 0.01 to 0.01 mS/cm; Temperature: 0.1°C (32.1°F)
- Temperature Accuracy ± 0.2 °C
- Weight 650 g
- Width 96 mm
Industrial process conductivity/temperature controllers CDTX-111 and CDTX-112 are panel instruments for in-process monitoring of conductivity. Range switch over and cell constant checks can both be freely set and adjusted during operation. Unique signal collection and processing technology, and a special thick film circuit are employed to ensure accurate measurements and stable operation. Other features include linearized data, automatic temperature compensation, and maintenance-free cells. The control functions trigger relays based on conductivity setpoints. The CDTX-111 and CDTX-112 are ideal auxiliary instruments for many types of water testing applications.
Specifications
Display Type
CDTX-111: LED, 13 mm height
CDTX-112: LCD, 13 mm height
Measurement: 0 to 18 M? or 0 to 19.99 µS/cm
Range (Depending upon cell constant)
CDTX-111: 0 to 199.9 µS/cm; 0 to 1999 µS/cm
CDTX-112: 0 to 999.9 µS/cm; 0 to 9999 µS/cm, 0 to 100mS/cm, 0 to 600 mS/cm
Temperature: 0 to 100 °C (32 to 212 °F)
Resolution: 0.01 M?
CDTX-111: 0.01 to 1 µS/cm
CDTX-112: 0.01 to 0.01 mS/cm
Temperature: 0.1 °C (32.1 °F)
Accuracy: ±1% FS, ± 0.2 °C
Temperature: Automatic/manual
Compensation: 0 to 100 °C (32 to 212 °F)
Output Relays: 2 programmable, 10 A
Control Type: On/off
Relay Set Point Hysteresis: User programmable
Current Output
Type: Isolated 4 to 20 mA
Range: Selectable zero and span
Accuracy: ±0.02 mA
Maximum Load: 750 ?
Power Supply: AC 110V to 220V ±10%, 50/60 Hz
Weight
CDTX-111: 580 g (20.4 oz)
CDTX-112: 650 g (22.9 oz)
Dimensions
CDTX-111: 96 × 48 × 110 mm (3.78 x 1.89 x 4.33")
CDTX-112: 96 × 96 × 110 mm (3.78 x 3.78 x 4.33")
Mount Type: Panel
Cut-Out Size
CDTX-111: 92 × 44 mm (3.6 x 1.73")
CDTX-112: 92 × 92 mm (3.6 x 3.6")
Enclosure Rating: IP54
Environmental Operating Ambient Temperature: -10 to 55 °C (14 to 131 °F)
Requirements
Relative Humidity: 5 to 95% non-condensing
Maximum Operating Altitude: 3000 m (10,000')
Read More
Specifications
Display Type
CDTX-111: LED, 13 mm height
CDTX-112: LCD, 13 mm height
Measurement: 0 to 18 M? or 0 to 19.99 µS/cm
Range (Depending upon cell constant)
CDTX-111: 0 to 199.9 µS/cm; 0 to 1999 µS/cm
CDTX-112: 0 to 999.9 µS/cm; 0 to 9999 µS/cm, 0 to 100mS/cm, 0 to 600 mS/cm
Temperature: 0 to 100 °C (32 to 212 °F)
Resolution: 0.01 M?
CDTX-111: 0.01 to 1 µS/cm
CDTX-112: 0.01 to 0.01 mS/cm
Temperature: 0.1 °C (32.1 °F)
Accuracy: ±1% FS, ± 0.2 °C
Temperature: Automatic/manual
Compensation: 0 to 100 °C (32 to 212 °F)
Output Relays: 2 programmable, 10 A
Control Type: On/off
Relay Set Point Hysteresis: User programmable
Current Output
Type: Isolated 4 to 20 mA
Range: Selectable zero and span
Accuracy: ±0.02 mA
Maximum Load: 750 ?
Power Supply: AC 110V to 220V ±10%, 50/60 Hz
Weight
CDTX-111: 580 g (20.4 oz)
CDTX-112: 650 g (22.9 oz)
Dimensions
CDTX-111: 96 × 48 × 110 mm (3.78 x 1.89 x 4.33")
CDTX-112: 96 × 96 × 110 mm (3.78 x 3.78 x 4.33")
Mount Type: Panel
Cut-Out Size
CDTX-111: 92 × 44 mm (3.6 x 1.73")
CDTX-112: 92 × 92 mm (3.6 x 3.6")
Enclosure Rating: IP54
Environmental Operating Ambient Temperature: -10 to 55 °C (14 to 131 °F)
Requirements
Relative Humidity: 5 to 95% non-condensing
Maximum Operating Altitude: 3000 m (10,000')
PDFs & Manuals