								PHCN-961-Series
Panel and Wall Mount pH Controllers
			Models In Stock
	- Measure Temperature and Control pH or ORP
 - Built-In Memory Backup When Power Fails
 - NEMA 4X (IP65) Wall or Panel Mount Enclosures
 - Range of -2 to 16 pH
 
PHCN-961-Series
					From
					$
					1,208.85
				
						Models In Stock
				
			
		    Product Overview
	- Accuracy ± 1 mV
 - Calibration Note pH Calibration modes: Programmable from 1 to 999 hours
 - Cutout Dimensions 93.5 x 93.5 mm
 - Data Interface RS485
 - Deadband pH : 0.01 to 2 pH, ORP: 1 to 200 mV
 - Display Size 13.7 mm (0.54 in)
 - Display Type 4 Digit LCD
 - Display Type Note 4-digit LCD, 13.7 mm (0.54"); blue backlit
 - Enclosure Ratings IP65, NEMA Type 4X
 - Frequency 50/60 Hz
 - Impedance 600 Ω
 - Impedance Input 10¹³ Ω
 - Input Range Note pH Sensor Input: -2.00 to 16.00 pH; ORP Sensor Input: -999 to +999 mV
 - Measurement Resolution pH: 0.01, ORP: 1 mV
 - Number of Relays 3
 - Operating Humidity 10 to 95% RH
 - Operating Temperature, Max 50 °C
 - Operating Temperature, Min -10 °C
 - ORP Accuracy ± 1 mV
 - Output Detail 0 to 20 mA/4 to 20 mA isolated current output
 - pH Accuracy ± 0.01 pH
 - Process Temperature, Max -9.9 °C
 - Process Temperature, Min 130 °C
 - Relay Note Three SPST relays, rated 250V @ 1 A
 - Sensor-Transducer Connection BNC Connector
 - Supply Voltage 110/220 Vac
 - Temperature Accuracy ± 0.5 °C
 - Temperature Compensation Automatic with ±10°C offset adjustment or manual
 - Temperature Resolution 0.1 °C
 - Temperature Sensor Type 1000 Ω RTD
 
The PHCN-961/962 series of pH controller and transmitter provides a reliable method of monitoring and controlling pH in water treatment, electrolytic water cleaning, chemical industry, food process, cleaning water or wastewater treatment, and neutralization processes.
The controllers standard features include a digital display capable of displaying pH readings between -2 and 16 pH or ORP readings between -2000 an 2000 mV. Additional features include temperature, and status of relays, adjustable dual alarm set points, dead band adjustments of 0.01 to 2 pH of the set point, and menudriven program to set up pH or ORP calibration.The PHCN-961/962 is a basic pH or ORP controller, it includes a NEMA 4X (IP65) enclosure, digital display, two separate set points for high and low alarms, adjust dead bands, three 1 amp SSR. Accepts one pH or ORP electrode input through supplied pH transmitter.