FE-HEATER

204 °C Max Constant Wattage Heating Cable 120-480 Vac

  • Continuous Exposure Rating up to 400°F
  • Low Watt Density
  • Parallel Resistance Heater
  • Cut-to- Length at the Job Site
FE-HEATER
From $ 5.10
204 °C Max Constant Wattage Heating Cable 120-480 Vac FE-HEATER FE-HEATER
loading all models
Product Overview
  • Approvals Group B
  • Cable Length 1 ft
  • Cable Length, Max 180 ft
  • Cable Material Nickel, Copper
  • Dielectric Strength 2500 V
  • Heater Wire Material Nichrome
  • Insulation 20 Mil FEP
  • Module Length 2 ft
  • Operating Temperature, Max 148 °C
  • Operating Temperature Note Exposure Temperature: 0 to 204 °C; Short Term Exposure Temperature: 232 °C
  • Purchase Note Use quantity to indicate length of cable to purchase (increments of 1 foot), min purchase of 25 ft
  • Wire Gauge 12 AWG
  • Wire Thickness 0.3 in
  • Wire Width 0.2 in
The FE cable heating element is tension wrapped and covered with a fluorocarbon film and enclosed in a minimum 20 mil FEP abrasion resistant extruded jacket. This tough outer cover provides moisture and dielectric protection as well as resistance to abrasion.
A tinned copper overbraid provides additional protection and electrical ground return path.

APPLICATIONS
OMEGALUX® FE cable is a low Watt density electrical resistance heater. It is designed for freeze protection and mid-range process temperature control and maintenance applications in lines periodically purged with 150 PSIG steam.
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getReviews, 3ms
  • REVIEWS, PRODUCT
  • bvseo-msg: The resource to the URL or file is currently unavailable.;

We purchased 8’ of fe8-480b and only need 2’. Can it be cut? It didn’t come with ends. What should we order for that? It’s self regulating so do we need a temperature control?

Asked by: psrien2
The FE-UC-KIT is sold for terminating the cable which can be cut. It is self regulating so a Controller is not required though some type of over temperature device to detect and open the circuit if an excessive temperature is reached is advised.
Answered by: ApplicationsEngineerANB
Date published: 2020-08-20
  • y_2025, m_10, d_30, h_5CST
  • bvseo_bulk, prod_bvqa, vn_bulk_3.0.42
  • cp_1, bvpage1
  • co_hasquestionsanswers, tq_1
  • loc_en_US, sid_FE12-120B, prod, sort_[SortEntry(order=NUM_ANSWERS, direction=DESCENDING)]
  • clientName_omega
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getContent, 3ms
  • QUESTIONS, PRODUCT
en-US
en
Save Configuration