1-800-663-4209 | Welcome to our new website, found an issue or bug? Please report it here

OM-USB-3100-Series
4/8/16-Channel Analog Voltage Output USB Data Acquisition Modules
- 4, 8, or 16 Analog Voltage Outputs
- 16-Bit Resolution
- 100 S/s Update Rate
- 8 Digital I/O
OM-USB-3100-Series
From
$
320.00

Product Overview
- Accuracy ± 0.006%
- Calibration Calibration Method: Software calibratio, Calibration Interval: 1 year
- Configuration Parameters Pull-Up/Down Configuration, User-Configurable Input/Output
- Data Interface Ethernet, USB 2.0
- Digital Input Digital: Low = –0.5 to 0.8 Vdc
- Digital Output ±3.5 mA
- Electrical Connection Screw Terminal
- Frequency Input Range 1 MHz
- Height 36 mm
- Input Configuration Connected Software
- Input Voltage Note Absolute Maximum Input Voltage: 5.5V
- LED Indicators Supply Status LED
- Length 127 mm
- Memory EEPROM: 256 bytes
- Microcontroller Type: High performance 8-bit RISC microcontroller, Program Memory: 16,384 words, Data Memory: 2048 bytes
- Operating Temperature, Max 70 °C
- Operating Temperature, Min 0 °C
- Output Noise Output: 0 to 10V Range: 14.95 µVrms typical, ±10V Range: 31.67 µVrms typical
- Output Resolution 16 bits
- Output Settling Time 25 µs
- Pull-up Resistor 47 kΩ
- Relative Humidity 0 to 90% RH non-condensing
- Sampling Rate 100 Hz (100 updates/second)
- Sampling Rate Note Single-Channel: 100 S/s maximum, system-dependent, Multichannel: 100 S/s/#ch maximum, system-dependent
- Slew Rate 1.20V/µs
- Stability ±10 ppm/SQRT(1000 hrs)
- Storage Temperature, Max 85 °C
- Storage Temperature, Min -40 °C
- Supply Voltage 5 Vdc
- Temperature Coefficient ±10 ppm/°C
- Voltage Output Calibrated: ±10V, 0V to 10V, Uncalibrated: ±10.2V, -0.04V to 10.08V
- Warm Up Time 15 min
- Weight 159 g
- Width 89 mm
The new OM-USB-3101, OM-USB-3103, and OM-USB-3105 are voltage output USB 2.0 full-speed modules. Each module provides 4, 8, or 16 voltage outputs. All modules provide synchronous and concurrent voltage updates. All OM-USB-3100 Series modules provide eight digital I/O lines and one 32-bit event counter and are powered by the 5V USB supply from the computer.
Analog Output
All OM-USB-3100 Series modules provide either 4, 8, or 16 channels of 16-bit analog output. Each channel is software-selectable for either a bipolar voltage output range of ±10 V or unipolar range of 0 to 10V. Channel outputs can be updated individually or simultaneously.
Software
The OM-USB-3100 Series modules ship with an impressive array of software including the new TracerDAQ®, a full-featured, out-of-the-box data logging, viewing, and analysis application. Driver support and detailed example programs are included for Universal Library programming libraries for Microsoft® Visual Studio® programming languages, and other languages, including DASYLab®, and ULx for NI LabVIEW® (comprehensive library of Vls and example programs compatible with 32-bit and 64-bit LabVIEW v8.5 through 2012) and InstaCalTM installation, calibration and test utility-powerful solutions for programmers and non-programmers alike. These modules operate under Microsoft Windows® XP (32-bit only) and VISTA/7 AND 8 (32-bit and 64-bit) operating systems.
Synchronous DAC Updates
All OM-USB-3100 Series modules have a synchronous DAC load connection pin (SYNCLD) that simultaneously updates DAC outputs on multiple devices. You can configure this with software as an input (slave mode) or as an output (master mode). In slave mode, the SYNCLD pin receives the D/A LOAD signal from an external source. When the SYNCLD pin receives the trigger signal, the analog outputs are updated simultaneously. In master mode, the internal D/A LOAD signal is sent to the SYNCLD pin. You can then synchronize with a second device of the same type and simultaneously update the DAC outputs on each device. On power up and reset, the SYNCLD pin is set to slave mode (input).
Digital I/O
All OM-USB-3100 Series modules have eight bidirectional digital I/O connections. The digital DIO lines can be independently programmed for input or output. All digital pins are floating by default. A screw terminal connection is provided to configure for pull-up (5V) or pull-down (0V).
Counter Input
Each OM-USB-3100 Series module has a 32-bit event counter for counting TTL pulses. The counter increments when the TTL levels transition from low to high. The counter accepts frequency inputs of up to 1 MHz.
Analog Output
All OM-USB-3100 Series modules provide either 4, 8, or 16 channels of 16-bit analog output. Each channel is software-selectable for either a bipolar voltage output range of ±10 V or unipolar range of 0 to 10V. Channel outputs can be updated individually or simultaneously.
Software
The OM-USB-3100 Series modules ship with an impressive array of software including the new TracerDAQ®, a full-featured, out-of-the-box data logging, viewing, and analysis application. Driver support and detailed example programs are included for Universal Library programming libraries for Microsoft® Visual Studio® programming languages, and other languages, including DASYLab®, and ULx for NI LabVIEW® (comprehensive library of Vls and example programs compatible with 32-bit and 64-bit LabVIEW v8.5 through 2012) and InstaCalTM installation, calibration and test utility-powerful solutions for programmers and non-programmers alike. These modules operate under Microsoft Windows® XP (32-bit only) and VISTA/7 AND 8 (32-bit and 64-bit) operating systems.
Synchronous DAC Updates
All OM-USB-3100 Series modules have a synchronous DAC load connection pin (SYNCLD) that simultaneously updates DAC outputs on multiple devices. You can configure this with software as an input (slave mode) or as an output (master mode). In slave mode, the SYNCLD pin receives the D/A LOAD signal from an external source. When the SYNCLD pin receives the trigger signal, the analog outputs are updated simultaneously. In master mode, the internal D/A LOAD signal is sent to the SYNCLD pin. You can then synchronize with a second device of the same type and simultaneously update the DAC outputs on each device. On power up and reset, the SYNCLD pin is set to slave mode (input).
Digital I/O
All OM-USB-3100 Series modules have eight bidirectional digital I/O connections. The digital DIO lines can be independently programmed for input or output. All digital pins are floating by default. A screw terminal connection is provided to configure for pull-up (5V) or pull-down (0V).
Counter Input
Each OM-USB-3100 Series module has a 32-bit event counter for counting TTL pulses. The counter increments when the TTL levels transition from low to high. The counter accepts frequency inputs of up to 1 MHz.
PDFs & Manuals
Software & Drivers
Show Ratings & Reviews