Product Specs
<< See all Product ModelsBrand |
![]() |
Accuracy | ± 0.8 % |
Accuracy Detail | ± (0.8% of rdg + 0.2% FS) |
Additional Features 1 | Power Supply Included |
Calibration | NIST 5-Point Certificate |
Data Interface | RS232 |
Display Type | LCD |
Electrical Connection | 8-pin mini DIN |
Electrical Output | 0 to 5 V |
Height | 4.1 in |
Humidity Range | 0 to 100% RH non-condensing |
Materials, Wetted | Aluminum, Brass, Epoxy, FKM, Glass, Gold, Silicone, Stainless Steel |
Measurable Flow Rate | 125% |
Media Compatibility | Air, Gases, Nitrogen, Oxygen |
Operating Pressure, Max | 145 psi |
Operating Pressure, Min | 0 psi |
Operating Temperature, Max | 50 °C |
Operating Temperature, Min | -10 °C |
Output Signal | Voltage |
Pressure Drop, Min | 1 psi |
Process Connection Size | 1/8 in |
Process Connection Type | NPT Female |
Repeatability | ± 0.2% |
Response Time | 10 ms |
Response Time Note | 10 ms typical default response time for 63.2% of a step change. A variable register allows response time to be field adjustable to a certain extent via RS232 communications. The primary trade-off for response time is signal noise |
Span Shift | 0.02% FS/°C/atm |
Supply Current | 35 mA |
Supply Power Note | 35 mA typical current draw; 100 mA available supply recommended |
Supply Voltage | 7 to 30 Vdc |
Turndown Ratio | 200:1 |
Volumetric Flow Rate, Max | 10 SLM |
Volumetric Flow Rate, Min | 0.05 SLM |
Width | 1.1 in |
See All Specs |
PDFs & Manuals
Accessories
Portable battery pack cradle. Not for use with the in-B in portable meter version
$284.43