BV2000-BR-Series
Low Cost Brass Body Turbine Flow Meters
- Compact size
- Measurement in any meter orientation
- Operating pressure up to 362.50 psi (25 bar)
- Temperature range of –4…212° F (–20…100° C)
BV2000-BR-Series
From
$
174.38

Product Overview
- Accuracy ± 3 %
- Approvals KTW, W270, FDA - 21 CFR 175.300
- Burst Pressure 2900 psi Maximum
- Electrical Output Amplified Square Wave
- Filter 20 to 40 microns Recommended
- Materials, Wetted Brass, Graphite, PA12 Ferrite, PTFE
- Media Compatibility Liquids
- Operating Pressure, Max 360 psi
- Operating Temperature, Max 100 °C
- Operating Temperature, Min -20 °C
- Output Detail Max. 20 mA (Pull-up resistor required. See wiring diagram in User Manual.), Output (Hz): NPN sinking open collector
- Output Signal DC Pulse
- Process Connection Size 3/8 in
- Repeatability <0.50%
- Repeatability Note <0.50% under the same operating conditions
- Supply Current 8 mA
- Supply Voltage 5 to 24 Vdc
- Viscosity Range 0 to 16 cSt
- Weight 15 g
MEASURING PRINCIPLE
The rotor is turned by the liquid force proportional to flow. A Hall effect sensor supplies pulses that can be used for digital or analog signal processing. The generated pulses are specified as a K-factor.
OPERATING PRINCIPLE
Liquid flow causes a bladed turbine inside the meter housing to turn at an angular velocity directly proportional to the velocity of the liquid measured. As the blades pass beneath a magnetic pickup coil, a frequency signal is generated.
Each pulse is equivalent to a discrete volume of liquid. The frequency pulse is directly proportional to the turbine angular velocity and the flow rate.
The large number of pulses provides high resolution. As the mass of the turbine is small, the response time is fast. It is not necessary to install a straight length of pipeline upstream of the meter. The simple mechanical construction of the Vision meter provides a long lifespan without any loss of accuracy. Pressure spikes less than the burst pressure rating do not affect the measurements.