Skip to search Skip to main content Skip to navigation

1-800-663-4209 | Welcome to our new website, found an issue or bug? Please report it here

We noticed you are in , please visit your local site by clicking the below link for regional offers and support.

ILD44-UTP-C4EI

Large Display Meters & PID Controllers

$2,381.01 / each

Item# ILD44-UTP-C4EI

In Stock

Lead Time (If not in stock): 13 weeks

Product Specs

<< See all Product Models
Brand
A/D Conversion Dual slope
Accuracy ± 0.5 °C
Accuracy Detail ±0.5°C temperature; 0.03% rdg
Alarm modes Band, High/Low, Latch/Unlatch, Normally Open/Closed, Process/Deviation
Common Mode Rejection 120 dB
Control Mode Reverse (heat) or direct (cool)
Current Measurement Range 0 to 20 mA
Data Interface Ethernet, RS485, RS422
Data Interface Note Ethernet : Standards compliance IEEE 802.3 10Base-T Supported Protocols : TCP/IP, ARP, HTTPGET RS232/RS422/RS485/MODBUS : Selectable from menu; both ASCII and MODBUS protocol selectable from menu; programmable 300 to 19.2 K baud; complete programmable setup capability; program to transmit current display, alarm status, min/max, actual measured input value and status. RS485 : Screw terminals
Decimal Selection 0, 0,001, 0,01, 0,1
Digital Filter Programmable
Display Color Red, Green, Amber
Display Size 57.2 mm (2.25 in)
Display Type 4 Digit, 7 Segment LED
Display Type Note 4-digit or 6-digit, 7-segment LED 57.2 mm (2.25") or 101.6 mm (4.00") red, green and amber programmable colors for process variable, set point and temperature units
Electrical Connection Screw Terminal
Enclosure Ratings IP65, NEMA Type 4
Excitation Voltage Note Optional in Place of Communication
GrossWeightValue 0.15
Impedance Input 10 MΩ for 100 mV, 1 MΩ for 1 or 10 Vdc
Input Configuration Single-ended
Input Type Themocouple, RTD, Current, Voltage
Isolation Power to Input/Output: 2300 Vac per 1 min test (RS232/485, input or output) Between Inputs: 500 Vac per 1 min test
Normal Mode Rejection 60 dB
Offset Adjustment -1999 to +9999
Operating Temperature, Max 40 °C
Operating Temperature, Min 0 °C
Polarity Unipolar
Power Consumption 22.5 W
RTD Type 100/500/1000 Ω Pt sensor, 2-, 3- or 4-wire; α= 0.00385 or 0.00392
Reading Rate 3 samples/sec
Relative Humidity 90% RH non-condensing
Resolution 1°/0.1°; 10 µV process
Sensor/Transmitter Power 24 Vdc @ 25 mA
Series ID iLD-Series
Set Point Adjustment -1999 to 9999 counts
Span Adjustment 0.001 to 9999 counts, programmable
Step Response 0.7 sec for 99.9%
Supply Power Note 100 to 240 Vac ±10%, 50/60 Hz
Supply Voltage 100 to 240 Vac
Temperature Stability RTD: 0.04°C/°C;Thermcouple @ 25°C (77°F): 0.05°C/°C—cold junction
Thermocouple Lead Resistance, Max 100 Ω
Thermocouple Type J, K, T, E, R, S, B, C, N, L
Voltage Measurement Range 0 to 100 mV, 0 to 1 V, 0 to 10 Vdc
Warm-Up to Rated Accuracy 60 min
Country of Origin Mexico
See All Specs Show Less
Large Display Meters & PID Controllers ILD44-UTP-C4EI ILD44-UTP-C4EI
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getReviews, 4ms
  • REVIEWS, PRODUCT
  • bvseo-msg: The resource to the URL or file is currently unavailable.;
en-US
en
Save Configuration