1-800-663-4209 | Welcome to our new website, found an issue or bug? Please report it here
PX419S20-015G5V
0 to 15 psi, Gauge, 0 to 5 Vdc, 2" Tri-Clamp, Mini DIN 43650 C

Choose a Variant
Electrical Connection
Measurement Pressure Type
Measurement Pressure, Max
Measurement Pressure, Min
Accuracy
Product Specs
<< See all Product ModelsBrand |
![]() |
ADC Resolution | None |
Accuracy | ± 0.08 % |
Accuracy Class | < 0.1% |
Accuracy Detail | ± 0.08% best straight line (linearity, hysteresis and repeatability combined) compound gage models calibrated in positive direction only |
Additional Features 1 | None |
Bandwidth | DC to 1 kHz |
Burst Pressure | 4x Full Scale to Maximum Rated Flange Pressure |
Compensated Temperature, Max | 87.7 °C |
Compensated Temperature, Min | -1.1 °C |
Electrical Connection | DIN 43650 C (solenoid valve) |
Electrical Output | 0 to 5 V |
Enclosure Ratings | IP65, IP67 |
Fill Fluid | NEOBEE M5 food grade |
Insulation Resistance | 100 MΩ @ 50 Vdc |
Materials, Wetted | 316L Stainless Steel |
Measurement Pressure Type | Gauge |
Measurement Pressure, Max | 15 psi |
Measurement Pressure, Min | 0 psi |
Operating Temperature, Max | 115 °C |
Operating Temperature, Min | -15 °C |
Output Signal | Voltage |
Pressure Cycles | 1 million |
Process Connection Note | 1 1⁄2" and 2" Tri-GripTM (Tri-Clamp® compatible) Fitting: 600 bar using suitable clamp |
Process Connection Size | 2 in |
Process Connection Type | Tri-Clamp |
Proof Pressure | 6x Full Scale up to 2000 psi |
Response Time | <1 ms |
Shock | 50 g, 11 ms half sine (under test) |
Shunt Calibration Value | 5-point NIST traceable calibration with zero and span values, calibrated in horizontal direction |
Span Setting Adjustable Range | ± 0.5% FS |
Stability | ± 0.1% |
Supply Power Note | 10 to 30 Vdc @ 10 mA |
Supply Voltage | 10 to 30 Vdc |
Thermal Effect on Span error, Max | 0.005, 0.005%/°F |
Thermal Effect on Zero error, Max | 0.005%/°F, 0.005 |
Vibration | ± 20 g |
Weight | 285 g |
Zero/Balance Error | ± 0.5% |
Zero/Balance Error Note | ± 0.5% FS typical ± 1% max (for ranges ≤ 5 psi ± 1% typ. ± 2% max) |
See All Specs |
PDFs & Manuals
Software & Drivers
Accessories
Show Ratings & Reviews