1-800-663-4209 | Welcome to our new website, found an issue or bug? Please report it here

PX01
High Accuracy, Hermetically Sealed Pressure Transducers
Models In Stock
PX01
From
$
1,017.25
Models In Stock

Product Overview
Show Ratings & Reviews
Rated 5 out of
5
by
B Mo from
Good working transducer
The transducer was received before the estimated lead time. Great products for a fair price.
Date published: 2024-10-09
Rated 5 out of
5
by
Lori A from
Lead time was long but part looks great!
Works great.....lead time was very long but part was needed.
Date published: 2023-06-29
Can I connect these to a DAQ system?
Yes these pressure transducers can be connect to a DAQ system. They produce a linear analog in mV, mA or VDC representing the level of gas of liquid pressure being measured.
Date published: 2020-06-04
We would like to measure the resistance between two Signal Pins (A and B) and also the resistance between the two Excitation Pins (C and D). What is the nominal resistnace values and will I require a standard input current?
Thank you for your inquiry
for this transducer the resistance is not applicable.
The current would be what is the factor.
That should be above 22 ma.
Date published: 2020-09-25
Does orientation of the transducer affect the accuracy of the readings?
Orientation of this pressure transducer would have a minimum effect on the accuracy.
Date published: 2020-02-15
Can the transducer have a custom cable length? If so, what is the maximum available custom length?
Thank you for your inquiry. The PX01 Series in an older unit. We have newer sensors with better accuracy the most like would also cost less. Suggest your contact us a 1-800-826-6342 and ask for the Pressure group to discuss your requirements.
Date published: 2021-03-23
Can you please explain the maximum temperature compensation? I notice it states the max temperature compensation is at 71°C. What happens to the accuracy of the transducer if I exceed this temperature, say I am running my system at 85°C?
If you remain within Compensated Temperature Range the Zero and Span Thermal Effect will be 0.003% per Degree F change. If you are above the Compensated range the Thermal Effect will be greater. We do not have data for how much the shift would be when operating out of the Compensated Temperature range.
Date published: 2022-10-19
Where is the pdf for these? You used to have one listed.
Dear FrankM, thank you for reaching out, We are trying to get rid of PDF files and make them available on the web now. Here is a link from the older site you can still use though: https://br.omega.com/omegaFiles/pressure/pdf/PX01-I.pdf
https://br.omega.com/omegaFiles/pressure/pdf/PX01-5V.pdf
Date published: 2021-10-03
Is ±0.19 accuracy in BFSL?
Hello,
Yes, that is correct. +/- 0.19 BSFL
Date published: 2020-04-15