Models In Stock
- 1500 VRMS Isolation with Optical Couplers and Power dc-to-dc Converter (6,000 Vdc, 1 min)
- Industrial Surge Protection Devices and 15 KV ESD Protected RS-232 Inherent
- Four LED Diagnostic Indicators
- 115.2 K BPS (BAUD) at 0.8 mile (1.3 km), 38.4 K BPS (BAUD) at 1 mile (1.6 km)
DCP-485
From
$
490.23
Models In Stock

Product Overview
- Status Control false
- Altitude 15000 ft
- Baud Rate 115.2 K, 57.6 K, 38.4 K, 19.2 K, 9.6 K, 4.8 K, 0 to 2.4 K
- Capacitance 25 pF per foot
- Capturing Mode Asynchronous 4–wire duplex, 2–wire half duplex, 2–wire simplex
- Channels (1) TD, RD
- Controller Options (1) RTS, DTR
- Current Output 28 mA max/output
- Height 4.3 in
- Impedance Input 12 kΩ min/input
- Input Type RS232
- Isolation Surge: 6000 Vdc, 1 min, Continuous: 1500 Vrms
- Length 0.89 in
- Mounting DIN-Rail Mounting
- MTBF (2) >100,000 hrs
- Multidrop Units, Max 32
- Null Modern Switch Note 1 (Reverses RS232 pins 2 and 3)
- Number of Channels 1
- Operating Temperature, Max 60 °C
- Operating Temperature, Min 0 °C
- Output Cable Connector Type RS485: Pluggable solderless screw terminals
- Protection Mode Surge Protection: (dc input and RS232 inputs and outputs, RS485 inputs and outputs)
- Relative Humidity 0 to 95% RH, Non-Condensing
- Storage Temperature, Max 70 °C
- Storage Temperature, Min 0 °C
- Supply Power Type DC
- Supply Voltage 10 to 30 Vdc
- Switch Note TD Term - switches a 120 Ω termination resistor across the RS485 transmit data lines TD A & TD B. RD Pull Up/Term/Pull Dn - RD Term switches a 120 Ω termination resistor across the RS485 receive data lines. RD Pull Up & RD Pull Dn switch a pull up resistor to RD B’ and a pull down resistor to RD A’, respectively. TD Cont En/Ctrl’d - select continuous enable or RS232 side signal control of the RS485 transmitter. RD Cont En/Ctrl’d - select continuous enable or RS232 side signal control of the RS485 receiver.
- Switch Type TD Term, RD Pull Up/Term/Pull Dn, TD Cont En/Ctrl’d
- Transmission Distance 1.3 km, 1.5 km, 1.6 km, 4.2 km, 5.6 km, 6.4 km, 11.3 km
- Weight 130 g
- Width 3.3 in
Description
The DCP-485 is a compact RS-232- to-RS-485 converter which features a complete electrical isolation barrier and heavy duty electrical surge protectors. These devices feature a DIN rail mountable enclosure, for application to a junction box, a panel, a relay rack, the side of your computer, or anywhere a DIN rail can be mounted. Isolation is provided by optical couplers and a transformer-isolated dc-to-dc converter. The RS-232 connection is made through male or female EIA 9-pin D sub connectors, or a 3-wire RS-232 connection can be made through convenient pluggable screw terminals. The RS-485 connections are made through convenient pluggable solderless screw terminals. The DCP-485 series is designed for full duplex operation over two-wire pairs. Outputs are tri-state, allowing multidropping of up to 32 units. Data rates are up to 115.2 K bits per second (baud). Four diagnostic LED indicators are provided for installation guidance and system troubleshooting. The RS-232 interface includes Request To Send (RTS) and Data Terminal Ready (DTR), either of which can be used via a DIP switch to enable the RS-485 transmitter. Alternately, the DCP-485 offers automatic line switching: the RS-485 transmitter is enabled automatically by each character sent on the RS-232 Transmit Data (TD) line. Additionally, the RS-485 transmitter and receiver can be independently enabled continuously or under RS-232 control. A convenient null modem switch is provided for the data lines. Also, line termination switches independently connect line termination and line bias resistors to the RS-485 lines. The units are powered from wide-range voltages of +10 to +30 Vdc through pluggable solderless screw terminals.
PDFs & Manuals