CL900A-950A

Hot Point Dry Block Probe Calibrator With RS232 Output

  • Calibrates Thermistors, Thermocouples and RTD’s in Minutes
  • Highly Accurate ±0.8°C (±1.5°F) & Exceptional Stability ±0.2C (±0.3°F) for Precision Calibrations
  • Portable Rugged Design
  • Wide Temperature Range from Ambient +22 to 482°C (Ambient +40 to 900°F). Covers Most Industrial Applications
Hot Point Dry Block Probe Calibrator With RS232 Output CL900A-950A CL900A-950A
loading all models
Product Overview
  • Accuracy ± 0.8 °C (± 1.5 °F)
  • Accuracy Detail (1° resolution) CL900A with 152 mm (6") Test Well Inserts: ±0.8°C (±1.5°F) CL900A with 101.6 mm (4") Test Well Inserts: ±1.7°C (±3°F) CL950A: ±0.8°C (±1.5°F)
  • Additional Features 1 Portable
  • Control Microprocessor-based PID digital controller
  • Data Interface RS232
  • Height 312 mm
  • Length 191 mm
  • Operating Temperature, Max 38 °C
  • Operating Temperature, Min 5 °C
  • Power Consumption 1050 W
  • Power Consumption Note 115 Vac, 50/60 Hz, 230 Vac, 50/60 Hz, 1050 W
  • Process Temperature, Max 482 °C
  • Process Temperature, Min 22 °C
  • Process Temperature Note Ambient 22 to 482°C (ambient 40 to 900°F);Temperature Uniformity (within the Bottom 25 mm/1" of the Test Well): CL900A with 152 mm (6") Test Well Inserts: ±0.3%rdg CL900A with 101.6 mm (4") Test Well Inserts: ±0.4% rdg CL950A: ± 0.3% rdg
  • Temperature Stability ±0.15°C (±0.3°F)
  • Weight 11.4 kg
  • Well Type Single Well
  • Width 363 mm

OMEGA’s hot point™ calibrator is part of a new family of calibrators which allows calibration of thermistor, thermocouple and RTD probes quickly and easily with an accuracy to ±0.8°C (±1.5°F). An integral RTD sensor assures high measurement accuracy and repeatability. A built-in microprocessor-based PID digital controller assures exceptional stability. Setpoint and actual temperature are displayed, simultaneously. Temperature can be set in one degree increments from Ambient +22 to 482°C (Ambient +40 to 900°F).


The CL900A calibrator accepts a variety of optional inserts which are available in 4" and 6" depths, and probe diameters from 1/8" to 3/8". An undrilled insert is also available. The CL900A comes standard with a 1/4" diameter, 6" deep insert well, and insert removal tongs. Additional inserts can be ordered separately as required for other diameter probes. 6" depth inserts are used for probes 7" and longer. 4" depth inserts are used for probes 5" and longer..

PLEASE NOTE: Items listed as "Stock" require 5 Business Days for NIST Certification and Order Processing
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getReviews, 4ms
  • REVIEWS, PRODUCT
  • bvseo-msg: The resource to the URL or file is currently unavailable.;
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getContent, 20ms
  • QUESTIONS, PRODUCT
  • bvseo-msg: The resource to the URL or file is currently unavailable.;
en-US
en
Save Configuration