1-800-663-4209 | Welcome to our new website, found an issue or bug? Please report it here

DRA-TCI-RTI-Srs-Sig-Cond
DIN Rail 2 Wire Temperature Signal Conditioners/Transmitters
- DRA-TCI-2 Thermocouple Input Model
- DRA-RTI-2 RTD Input Model
- Isolated
- Linearized
DRA-TCI-RTI-Srs-Sig-Cond
From
$
250.68

Product Overview
- Status Control false
- Accuracy ± 0.1 %
- Accuracy Detail Including Linearity, Hysteresis and Repeatability
- Calibration Input span: Adjusted by three DIP switches and span potentiometer, Input Zero: Adjusted by three DIP switches and Zero potentiometer; Test Terminals: 40 to 200 mV represents 4-20 mA
- CMRR 127 dB typical DCto 60 Hz
- DIN Rail Size 35 mm
- Electrical Output 4 to 20 mA
- Enclosure Ratings IP20, IP40
- Height 3.23 in
- Isolation 1500 Vdc or peak ac
- Lead Compensation Error <0.1°C/20 Ohms lead resistance
- Length 3.9 in
- Loop Resistance Rmax (ohms) = (Vsupply - 10) / 0.02
- Materials Polycarbonate
- Mounting DIN rail
- Operating Temperature, Max 70 °C
- Operating Temperature, Min -20 °C
- Relative Humidity 5 to 95% RH
- Response Time 160 msec
- Span Setting Adjustable Range 26 to 810°C
- Storage Temperature, Max 85 °C
- Storage Temperature, Min -30 °C
- Supply Current 1 mA
- Supply Power 10 to 40 Vdc
- Supply Power Type DC
- Temperature Coefficient α=0.00385
- Temperature Stability <±0.1% of span/°C
- Weight 130 g
- Width 0.9 in
- Wiring/Connector Table 2
- Zero Setting Adjustable Range -62 to 232°C
Models DRA-TCI-2 and DRA-RTI-2 are linearized temperature transmitters that produce a 4-20 mA process signal that is directly proportional to temperature. These transmitters have exceptionally high input to output common mode rejection (CMR), a high degree of filtering that eliminates false output signals and provides a low ripple current. Model DRA-TCI-2 is available for thermocouple types J, K, T, E, R, S or B and provides exceptional temperature linearization by applying eight segment linearization circuitry. Model DRA-RTD-2 accepts 2 or 3 wire Pt-100 RTDs, alpha = 0.00385. Both models are field rangeable using a set of six internal dip switches for coarse ranging and front accessible zero and span potentiometers for fine adjustment. Test terminals are provided to monitor the transmitter’s 4-20 mA output without disturbing the actual process loop.
PDFs & Manuals
Show Ratings & Reviews
What is the calibrated range in deg C for the 4-20mA output of the DRA-RTI-2 as shipped from the factory?
Thank you for your question. We will require more information to help on this question, please email the DAS team at DAS@OMEGA.COM”
Date published: 2022-09-22
Hi, is there a manual for the DRA-RTI-2 model? I see the manual on the website for the DRA-TCI-2 model only. Thanks.
Thank you for your question. See link for DRA-RTI-2 manual:
https://www.omega.com/en-us/pdf-manuals
Date published: 2020-04-14