Product Overview
- Accuracy ± 0.02 %
- Approvals CE
- Electrical Output 4 to 20 mA
- Enclosure Ratings IP65, NEMA Type 12
- Gain Range 3.5 to 1 switched, 5 to 1 adjustable
- Height 120.65 mm
- Input Electrical Connection Screw terminals; access through 2 cable ports for wires 1 to 5 mm (0.04 to 0.2") diameter
- Input Noise 0 to 1.5 Hz: 1.4 µVRMS (RTI)
- Input Range 30 to 530 mV/V
- Input Type Voltage
- Length 54.86 mm
- Mounting Through holes in base by 2 screws and nuts, can be mounted to DIN 46277-1 rail
- Non-Linearity Better than 0.02%
- Number of Wires 2, 3
- Operating Temperature, Max 70 °C
- Operating Temperature, Min 0 °C
- Output Detail Output Current: 4 to 20 mA 2-wire or 0 to 20 mA 3-wire. Output Ripple:<50 µA p-p @ 10 kHz Output Filter: Cutoff frequency -3 dB @ 25 Hz second-order linearity: <0.02%
- Protection Oscillator Protection: Open and short circuit protected, Output Protection: Open and short circuit protected, Supply Protection: Reverse polarity protected
- Sensitivity Transducer : 30 to 530 mV/V
- Sensor Excitation 0.9 Vrms @ 5 kHz nominal, 13 kHz switchable
- Storage Temperature, Max 80 °C
- Storage Temperature, Min -40 °C
- Supply Power Type DC
- Supply Voltage 13 to 48 Vdc, up to 30 mA
- Temperature Coefficient Zero: Better than 0.01% FS/°C;Gain: Better than 0.01% FS/°C
- Weight 220 g
- Width 80 mm
The LDX-2 linear displacement transmitter is a two-wire, 4 to 20 mA conditioner for ac LVDT transducers. It is designed for use where long transmission distances are required before the signal can interface with a controller or meter. A feature of two-wire operation is its low susceptibility to noise and cable resistance, making it ideal for industrial environments. Two-wire operation enables both power and signal to use the same pair of wires.