RHB-CAC1S-Series
Compressed Air Dew Point Monitor
- NIST Traceable
- +/- 0.2 deg C
- Virtually Maintenance Free
- Easy to Install
RHB-CAC1S-Series
From
$
9,056.32

Product Overview
- Alarm Audible: >98 dB @ 2' ; Relay: 1 form “C”, non-latching; 10 A @ 240 Vac, 8 A @ 24 Vdc, 1 ⁄2 hp @ 240 Vac ; Visual: Flashing “ALARM” message
- Dew/Frost Point Accuracy 0.2°C (± 0.5°F)
- Dew/Frost Point Temperature Max 50 °C
- Display Type LED
- Electrical Output 4 to 20 mA
- Enclosure Aluminium
- Enclosure Ratings IP55, NEMA Type 12
- Measurement Type Dew Point
- Mounting Space-Saving Wall Mount
- Operating Temperature, Max 50 °C
- Operating Temperature, Min 0 °C
- Output Detail 4 to 20 mA (0 to 5 Vdc), -50 to 50°C (-58 to 122°F) or -60 to 75°C (-76 to 167°F)
- Process Connection Size 1/4 in
- Process Connection Type Compression Fitting
- Process Temperature, Max 50 °C
- Sample Flow Rate 0.5 to 5.0 scfh, Integral flow meter
- Sample Pressure 0 to 150 psig (higher pressures available, consult Engineering Department)
- Supply Voltage 90 to 250 Vac
- Temperature Accuracy ± 0.2 °C
- Temperature Accuracy Note ± 0.2 °C (± 0.5 °F)
Description
These compressed air dew point monitors have been designed to offer the highest level of reliability and accuracy available in such systems. They are fully NIST traceable and employ a chilled mirror sensor, the most accurate dew point sensing scheme available,to deliver consistent drift-free measurements without regular calibrations or sensor replacement.These compressed air monitors are complete dew point measuring systems. The ruggedized aluminum NEMA 12 (IP55) enclosure houses the sensor, control circuitry (including flow control) and is easily wall mounted to conserve space.Only the sample line and power connection are needed for the system to be operational.
The monitors also offer a programmable automatic balance control (ABC) cycle that corrects for the light-reducing effects of mirror contaminates and allows for continuous monitoring and virtually maintenance-free operation.
Specifications:
DEW/FROST POINT RANGE
Two-Stage (S2): -40 to 50°C (-40 to 122°F)
Three-Stage (S3): -60 to 50°C (-76 to 122°F)
Dew/Frost Point Accuracy: 0.20°C (± 0.5°F)
FUNCTIONALITY
Power: 90 to 250 Vac, 50 to 400 Hz
Operating Temperature: 0 to 50°C (32 to 122°F)
Sample Connection: 1/4" compression fitting
Sample Flow Rate: 0.5 to 5 SCFH integral flowmeter
Sample Pressure: 0 to 150 psig
(higher pressures available, consult Engineering Department)
Output: Analog: 4 to 20 mA (0 to 5 Vdc), 50 to 50°C (-58 to 122°F) or
-75 to 75°C (-103 to 167°F)
Compliance: 9.0 Vdc, 450 .
Display: Red LED, 0.5" tall 8-digit alphanumeric
ALARM:
Audible: >98 dba @ 2'
Relay: 1 Form C, non-latching 10 A @ 240 Vac, 8 A @ 24 Vdc, 1/2 HP @ 240 Vac
Visual: Flashing “ALARM” message