								I-7520-Series
RS-232 to RS-485 Converter, 3 kV Isolation
			Models In Stock
	- Auto Switching Baud Rate, 300 to 115,200 bps
 - 3000 VDC Isolation Protection on the RS-485 side
 - Power Input, +10 to +30 VDC
 - DIN-Rail Mountable
 
I-7520-Series
					From
					$
					182.00
				
						Models In Stock
				
			
		    Product Overview
	- Baud Rate 300 to 115200
 - Baud Rate Note Max. 1,200 m for at speed 9.6 kbps; Max. 400 m at 115.2 kbps
 - Cable Note Belden 8941 (2P twisted-pair cable)/Belden 8942 (4P twisted-pair cable), if different cables are used, the transmission distance may change
 - Cable Type 2P Twisted-Pair Cable, 4P Twisted-Pair Cable
 - Data Interface Note RS232: TxD, RxD, GND, RS485: Data+, Data-
 - Height 4.8 in
 - Input Cable Connector Type RS232: 9 - Pin Female D-Sub
 - Input Type RS232
 - Isolation Three Way Protection: 3000 Vdc
 - LED Indicators Power/Communication LED
 - Length 1.5 in
 - Materials ABS
 - Mounting DIN-Rail Mounting
 - Number of Channels 1
 - Operating Temperature, Max 75 °C
 - Operating Temperature, Min -25 °C
 - Output Cable Connector Type RS485: 2 Terminal Block 10-Pins, Removable
 - Power Consumption 1.2 W
 - Relative Humidity 10 to 90% RH, Non-Condensing
 - Self Tuner Yes, Asic Inside
 - Storage Temperature, Max 75 °C
 - Storage Temperature, Min -30 °C
 - Supply Power Type DC
 - Supply Voltage 10 to 30 Vdc
 - Supported Devices 256 (Without repeater)
 - Transmission Distance 4000 ft
 - Width 2.83 in
 
Most industrial computer systems provide standard RS-232 serial ports. Though widely accepted, RS-232 has limited transmission speed, range, and networking capabilities. The RS-422 and RS-485 standards overcome these limitations by using differential voltage lines for data and control signals, which transparently converts RS-232 signals into isolated RS-422 or RS-485 signal with no need to change any hardware or software. The I-7520/I-7520A lets you easily build an industrial grade, long-distance communication system using standard PC hardware.
The design of the isolation between the I-7520 and the I-7520R/AR is different. If the user wants to supply power from the PLC/PC, the I-7520R/AR should be used, otherwise the isolation will be broken. Refer to the I-7000 bus converter manual for detailed information.
				PDFs & Manuals
			
		Show Ratings & Reviews
 
			
	
	
	
Do you have any sample source code?
            Thank you for your question. There is no source for this device it is just a converter. Please download manual from the product page for detailed information.
            
            
    Date published: 2022-03-23
        Where is the Windows 11 driver for this device? I can only find Windows 7 drivers which do not work on W11.
            . We will require more information to help on this question, please email the DAS team at DAS@dwyeromega.com
            
            
    Date published: 2025-04-25