1-800-663-4209 | Welcome to our new website, found an issue or bug? Please report it here
DP9800-Series
8-Channel Benchtop Digital Thermometer Data Logger
Models In Stock
- High Precision
- USB PC Interface
- Thermocouple and RTD Models
- Built-In Display for Selected Channel or Scanned Channels
DP9800-Series
From
$
1,666.21
Models In Stock

Product Overview
- Accuracy ± 0.1 °C (± 0.18 °F)
- Accuracy Detail Thermocouples J, K, T, E, and N, better than ±0.1°C ±0.1% of range zero to span ±0.15% of range -100 to - 200°C (J, K, T, and E)
- Additional Features 1 Real Time Logging, AC Adapter Provided
- Calibration Note User facility incorporated; the instrument auto-calibrates on every A/D cycle
- Cold Junction Compensation Automatic, accurate reference
- Connection Note 8 x thermocouple, mini connectors
- Data Interface USB
- Display and Indications Channel number, measured temperature (°C or °F)
- Display Type Single 5 Digit LCD
- Display Type Note LCD, backlight, Display Resolution: Thermocouple ranges 0.1°C, Pt100 range 0.01°C
- Form factor Benchtop
- Input Type Note Thermocouples: R, S, and B, better than ±0.1°C ±0.15% of range Pt100 Range: Better than ±0.05°C ±0.1% of range
- Linearization Points ±0.05°C
- Logging Interval 0
- Material Construction Option N/A
- Measuring Range Type J: -200 to 750°C (-328 to 1382°F) Type K: -200 to 1200°C (-328 to 2192°F) Type T: -200 to 350°C (-328 to 662°F) Type E: -200 to 900°C (-328 to 1652°F) Type N: 0 to 1300°C (32 to 2372°F) Type R: 0 to 1760°C (32 to 3200°F) Type S: 0 to 1760°C (32 to 3200°F) Type B: 300 to 1800°C (572 to 3272°F)
- Number of Inputs 8
- Operating Temperature, Max 50 °C
- Operating Temperature, Min 0 °C
- Sampling Rate 0.5 Hz (2 seconds between updates)
- Storage Temperature, Max 70 °C
- Storage Temperature, Min -20 °C
- Supply Power Note 6 Vdc (5.5 to 9.0V) via universal mains adaptor (supplied), 120 to 250V, 50/60 Hz
- Supply Power Type DC
- Supply Voltage 6 Vdc
- Temperature Drift ±0.01% of span per °C
- Terminal block 8 x Pt100
- Thermal Effect Zero Shift ±0.01% of span per °C
- Thermocouple Type N/A
- User Interface Front panel key for channel number or auto-scan selection; PC software for all other functions
The DP9800 Series thermometer can be used in conjunction with a PC to provide accurate, versatile 8 channel thermocouple and Pt100 RTD temperature measurements, scanning and logging of measured values. It can also be used as a † œstand alone† indicator/ logger and incorporates a digital backlit LCD display of measured temperature. The built-in self-calibration facility for the DP9800-TC thermocouple model is a rapid and convenient method for on-site calibration and does not require any additional equipment other than a special, external link. Self-calibration of Pt100 ranges is equally simple and uses plug-in precision resistors. The DP9800 is designed to provide exceptional stability with high measurement resolution and represents an ideal crossover between plant practicality and laboratory performance at a very competitive price.The PC software supplied with the instrument allows control, measure and calibration functions.
Specifications
At an ambient temperature of 20 °C
Input/Ranges: Thermocouple to IEC 584
Type J: -200 to 750 °C (-328 to 1382 °F)
Type K: -200 to 1200 °C (-328 to 2192 °F)
Type T: -200 to 350 °C (-328 to 662 °F)
Type E: -200 to 900 °C (-328 to 1652 °F)
Type N: 0 to 1300 °C (32 to 2372 °F)
Type R: 0 to 1760 °C (32 to 3200 °F)
Type S: 0 to 1760 °C (32 to 3200 °F)
Type B: 300 to 1800 °C (572 to 3272 °F)
Pt100 to IEC751, 3-Wire: -200 to 850 °C (-328 to 1562 °F)
Note: all inputs are non-isolated and thermocouples must be ungrounded style.
Accuracy: Thermocouples J, K, T, E, and N, better than ±0.1 °C ±0.1% of range zero to span ±0.15% of range -100 to - 200 °C (J, K, T, and E)
Thermocouples: R, S, and B, better than ±0.1 °C ±0.15% of range
Linearization: ±0.05 °C
Pt100 Range: Better than ±0.05 °C ±0.1% of range
Zero Drift: ±0.01% of span per °C
Span Drift: ±0.01% of span per °C
Display: LCD, backlight
Display Resolution: Thermocouple ranges 0.1 °C, Pt100 range 0.01 °C
User Interface: Front panel key for channel number or auto-scan selection; PC software for all other functions
Indication: Channel number, measured temperature ( °C or °F)
Reference Junction: Automatic, accurate reference
Self Calibration: User facility incorporated; the instrument auto-calibrates on every A/D cycle
Sensor: Open circuit upscale indication, detection and indication (independent alarms should be used for process safety if required) Ambient Operating Temperature: 0 to 50 °C (32 to 122 °F)
Storage Temperature: -20 to 70 °C (-4 to 158 °F)
Input Terminations: 8 x thermocouple, mini connectors
Terminal Blocks: 8 x Pt100
PC Interface: USB
Power Supply: 6 Vdc (5.5 to 9.0V) via universal mains adaptor (supplied), 120 to 250V, 50/60 Hz
Logging Interval: 5 second to 1 hour
Read More
Specifications
At an ambient temperature of 20 °C
Input/Ranges: Thermocouple to IEC 584
Type J: -200 to 750 °C (-328 to 1382 °F)
Type K: -200 to 1200 °C (-328 to 2192 °F)
Type T: -200 to 350 °C (-328 to 662 °F)
Type E: -200 to 900 °C (-328 to 1652 °F)
Type N: 0 to 1300 °C (32 to 2372 °F)
Type R: 0 to 1760 °C (32 to 3200 °F)
Type S: 0 to 1760 °C (32 to 3200 °F)
Type B: 300 to 1800 °C (572 to 3272 °F)
Pt100 to IEC751, 3-Wire: -200 to 850 °C (-328 to 1562 °F)
Note: all inputs are non-isolated and thermocouples must be ungrounded style.
Accuracy: Thermocouples J, K, T, E, and N, better than ±0.1 °C ±0.1% of range zero to span ±0.15% of range -100 to - 200 °C (J, K, T, and E)
Thermocouples: R, S, and B, better than ±0.1 °C ±0.15% of range
Linearization: ±0.05 °C
Pt100 Range: Better than ±0.05 °C ±0.1% of range
Zero Drift: ±0.01% of span per °C
Span Drift: ±0.01% of span per °C
Display: LCD, backlight
Display Resolution: Thermocouple ranges 0.1 °C, Pt100 range 0.01 °C
User Interface: Front panel key for channel number or auto-scan selection; PC software for all other functions
Indication: Channel number, measured temperature ( °C or °F)
Reference Junction: Automatic, accurate reference
Self Calibration: User facility incorporated; the instrument auto-calibrates on every A/D cycle
Sensor: Open circuit upscale indication, detection and indication (independent alarms should be used for process safety if required) Ambient Operating Temperature: 0 to 50 °C (32 to 122 °F)
Storage Temperature: -20 to 70 °C (-4 to 158 °F)
Input Terminations: 8 x thermocouple, mini connectors
Terminal Blocks: 8 x Pt100
PC Interface: USB
Power Supply: 6 Vdc (5.5 to 9.0V) via universal mains adaptor (supplied), 120 to 250V, 50/60 Hz
Logging Interval: 5 second to 1 hour