1-800-663-4209 | Welcome to our new website, found an issue or bug? Please report it here
HH911T-HH912T
1 & 2 Channel 0.04% Accuracy 4 Thermocouple Types Meter
Models In Stock
- 1 Input HH911T or Dual Inputs HH912T with delta T
- Superior Accuracy ± (0.04% |rdg| + 0.3°C)
- Comes with NIST Traceable Certificate
- (No Points)
HH911T-HH912T
From
$
557.52
Models In Stock

Product Overview
- Altitude 0 to 15,000 ft
- Battery life 2000 hr
- Clock Elapsed statistics run time
- Display Type 4 Digit LCD
- Drop 4 drops from 1 m (3.3') to concrete
- Electrical Connection Miniature Male Thermocouple Connector
- Height 193 mm
- Measuring Temperature Range, Max 55 °C
- Measuring Temperature Range, Min -20 °C
- Shock 30 g half sine
- Temperature Accuracy ± 0.04% rdg + 0.3 °C
- Temperature Accuracy Note ± (0.04%
- Temperature Resolution 0.1 °C
- Temperature Sensor Type Thermocouple
- Thermocouple Type K
- Vibration Random 10 to 500 Hz, 0.03 g2 /Hz
- Width 84 mm
OMEGA’s new precision digital thermometers are compatible with Type K, J, T or E thermocouple probes to provide a wide range of temperature measurements from -250 to 1372°C (-418 to 2502°F). The HH911T and HH912T models offer single and dual channel inputs and boast a 2000 hour battery life using 3 AA batteries that are included. Both models provide a dependable and uninterrupted portable measurement capability without expensive batteries, AC adaptors or chargers.
The creative ergonomic design of these instruments makes them easy-to-read, hold, and clean. Designed for one-handed operation, these tools are comfortable to carry and use for extended periods of time.
Real-time statistical data increases user productivity, process efficiency and product quality. Displayed on-demand MIN, MAX, AVG, RNG and STDEV (standard deviation) provide critical process information and diagnostics that allow the user to analyze manufacturing processes on the fly and make immediate adjustments for maximum efficiency and quality. The temperature difference between Channel 1 and Channel 2 are also determined and displayed on demand.
Omega backs these durable instruments with a standard 3-year warranty and a 2-year calibration guarantee to ensure that your instrument is ready-to-use when you need it. Each unit is supplied with a NIST Calibration Certificate (No points).
Specifications
Basic Accuracy: ± (0.04% |rdg| + 0.3°C)
Connector Type: Mini-TC
Probe Zero Function: Resolution 0.1°C/°F/K
Display: 4-digit auto-resolution (0.1/1) with backlight and function annunciators
Reading Rate: 3/sec for readings and TREND indicators
Battery Type: 3 “AA” (IEC LR6, ANSI 15) alkaline (included)
Battery Life: 2000 hours
Statistics: Min, Max, Avg, Rng, T1-T2 (HH912T only) and Std Dev
Clock: Elapsed statistics run time
Dimensions: 193 H x 84 W x 28 D mm (7.6 x 3.3 x 1.1')
Weight: 362.9 g (12.8 oz)
Warranty: 3 year parts and workmanship
Calibration: Guaranteed for 2 years
Operating Environment
Temperature: -20 to 55°C (-4 to 131°F)
Humidity: 5 to 95%, 10 to 30°C (50 to 86°F)
Altitude: 0 to 4600 m (0 to 15,092')
Vibration: Random 10 to 500 Hz, 0.03 g2/Hz
Shock: 30 g half sine
Drop: 4 drops from 1 m (3.3') to concrete
Read More
The creative ergonomic design of these instruments makes them easy-to-read, hold, and clean. Designed for one-handed operation, these tools are comfortable to carry and use for extended periods of time.
Real-time statistical data increases user productivity, process efficiency and product quality. Displayed on-demand MIN, MAX, AVG, RNG and STDEV (standard deviation) provide critical process information and diagnostics that allow the user to analyze manufacturing processes on the fly and make immediate adjustments for maximum efficiency and quality. The temperature difference between Channel 1 and Channel 2 are also determined and displayed on demand.
Omega backs these durable instruments with a standard 3-year warranty and a 2-year calibration guarantee to ensure that your instrument is ready-to-use when you need it. Each unit is supplied with a NIST Calibration Certificate (No points).
Specifications
Basic Accuracy: ± (0.04% |rdg| + 0.3°C)
Connector Type: Mini-TC
Probe Zero Function: Resolution 0.1°C/°F/K
Display: 4-digit auto-resolution (0.1/1) with backlight and function annunciators
Reading Rate: 3/sec for readings and TREND indicators
Battery Type: 3 “AA” (IEC LR6, ANSI 15) alkaline (included)
Battery Life: 2000 hours
Statistics: Min, Max, Avg, Rng, T1-T2 (HH912T only) and Std Dev
Clock: Elapsed statistics run time
Dimensions: 193 H x 84 W x 28 D mm (7.6 x 3.3 x 1.1')
Weight: 362.9 g (12.8 oz)
Warranty: 3 year parts and workmanship
Calibration: Guaranteed for 2 years
Operating Environment
Temperature: -20 to 55°C (-4 to 131°F)
Humidity: 5 to 95%, 10 to 30°C (50 to 86°F)
Altitude: 0 to 4600 m (0 to 15,092')
Vibration: Random 10 to 500 Hz, 0.03 g2/Hz
Shock: 30 g half sine
Drop: 4 drops from 1 m (3.3') to concrete
Common Thermocouple Temperature Ranges | |||
Calibration | Temperature Range | Standard Limits of Error | Special Limits of Error |
---|---|---|---|
J | 0° to 750°C (32° to 1382°F) | Greater of 2.2°C or 0.75% | Greater of 1.1°C or 0.4% |
K | -200° to 1250°C (-328° to 2282°F) | Greater of 2.2°C or 0.75% | Greater of 1.1°C or 0.4% |
E | -200° to 900°C (-328° to 1652°F) | Greater of 1.7°C or 0.5% | Greater of 1.0°C or 0.4% |
T | -250° to 350°C (-328° to 662°F) | Greater of 1.0°C or 0.75% | Greater of 0.5°C or 0.4% |
PDFs & Manuals