1-800-663-4209 | Welcome to our new website, found an issue or bug? Please report it here

CN8200-Series
1/16 DIN Universal Input Autotune Controller with Ramp & Soak
Models In Stock
- Field-Configurable Universal Inputs
- Autotuning, Direct or Reverse-Acting for Both Outputs
- User-Selectable Ramp to Setpoint
- 8 Ramp and 8 Soak Segments
CN8200-Series
From
$
320.00
Models In Stock

Product Overview
- Accuracy ± 0.2 %
- Accuracy Detail ± 0.2% FS, ± 1 digit
- CMRR 100 dB
- Cold Junction Compensation 0.05°C/°C ambient
- Contacts Twin bifurcated
- Control Characteristics Set point Limits: Limited to configured range for thermocouple and RTD; limited to scaled range; Alarms: Adjustable for high/low; selectable process or deviation; Rate (Derivative): 0 to 2400 seconds; Reset (Integral): 0 to 9600 seconds; Cycle Time: 0.2 to 120 seconds; Proportional Band: 1 to span of sensor; Dead band: Negative span to positive span of sensor; Hysteresis: 1 to span of sensor; Autotune Damping: Adjustable (low, normal, or high); Ramp to Set point: 1 to 9999 minutes; Autotune: Operator-initiated from front panel; Manual Control: Operator-initiated from front panel
- Cutout Dimensions 45 x 45 mm
- Depth Behind Panel 100 mm
- Display Size 9.2 mm (.36 in)
- Display Type 4 Digit LED
- Display Type Note Dual LED—4-digit, orange: process display; green: menu/parameter display; 9.2 mm (0.36")
- Electrical Connection Screw Terminal
- Enclosure Ratings IP65, NEMA Type 4X
- Events/Alarms 1 to 8
- Form factor 1/16 DIN
- Hardware and Software Requirements, Min CN8-SW (Optional Software): Minimum Hardware and Software Requirements: IBM PC or 100% compatible, Windows 95/98/NT; RS485 interface or RS232 to RS485 converter; Software Compatibility: CN8200 Series controllers; Software Capability: Supports up to 254 CN8200 Series controllers
- Height 53.3 mm
- Input Type Thermocouple, RTD, mA, Voltage
- Input Type Note Input Type: See input table on next page Digital Input: For remote setpoint, remote standby or ramp/soak run and hold Thermocouple Lead Resistance: 100 Ω maximum for rated accuracy Decimal Position: Selectable
- Length 8.21 mm
- Loops 0 to 99
- Measurement Type Current, Temperature, Voltage
- Measuring Range Type J (Iron-Constantan): -200 to 760°C, Type K (CHROMEGA®-ALOMEGA®): -270 to 1354°C, Type T (Copper-Constantan): -270 to 400°C, Type N (OMEGALLOY®) : -268 to 1300°C, Type R (Pt/13%Rh-Pt) : -50 to 1768°C, Type S (Pt/10%Rh-Pt) : -50 to 1768°C, Type B (Pt/30%Rh-Pt/6%Rh) : 0 to 1820°C, Type C (W/5%Re-W/26%Re) : 0 to 2315°C, Type E (CHROMEGA®-Constantan) : -150 to 1000°C, NNM 18% molybdenum vs nickel -06% cobalt : 0 to 1410°, Platinel II : -100 to 1232°C, RTD ((3-wire) 100 Ω Pt) : -200 to 850°C, RTD ((3-wire) 100 Ω Pt) : -199.9 to 375.0°C, 0 to 1V : Scalable (-1999 to 9999) selectable 1 to 5V : Scalable (-1999 to 9999) selectable 0 to 5V : Scalable (-1999 to 9999) selectable 0 to 10V : Scalable (-1999 to 9999) selectable 10 to 50 mV : Scalable (-1999 to 9999) selectable 0 to 50 mV : Scalable (-1999 to 9999) selectable 0 to 10 mV : Scalable (-1999 to 9999) selectable 0 to 100 mV : Scalable (-1999 to 9999) selectable 4 to 20 mA : Scalable (-1999 to 9999) selectable 0 to 20 mA : Scalable (-1999 to 9999) selectable
- Memory Backup Solid State
- Number of Inputs 1
- Operating Temperature, Max 55 °C
- Operating Temperature, Min 0 °C
- Ramp and Soak 8 Ramp & Soak
- Ramp Setpoint 1 to 9999 minutes
- Ramp/Soak Time 0 to 9999 minutes
- Relative Humidity 90% RH, non-condensing
- Repeatability ± 1 count
- Sampling Rate 10 Hz (10 updates/second)
- Series Mode Rejection >70 dB
- Setpoint Resolution 1 count/0.1 count
- Supply Power Note 100 to 250V, 50/60 Hz (single-phase); 120 to 250 Vdc, 24 Vac/24 Vdc (optional)
- Temperature Stability 5 μV/°C Max
- Weight 226 g
- Width 53.3 mm
The CN8200 temperature/process controller is extremely versatile and user-friendly. The operator needs to review only those parameters relevant to the particular application during setup. A dual digital display offers optimum process information at a glance. Individual LED's identify the status of outputs, alarms, digital communications, and special options. The CN8200 features a NEMA-4X front panel and a universal power supply that accepts 100 to 250 Vac and 120 to 250 Vdc. A 24 Vac/24 Vdc power supply option is also available. Control algorithms available are P, PI, PD, PID, or ON/OFF. The autotune feature automatically sets proportional band, derivative, and integral before the process reaches setpoint. These parameters provide quick stabilization of processes with minimum overshoot, hunting, or cycling.
Eight-level ramp/soak control consisting of 8 ramps and 8 soaks is standard, and includes a decimal display on thermocouple ranges, digital display and signal filtering, and a percentage of power limit setting. The dual control outputs can be configured for a variety of control and alarm applications, and two dedicated alarm outputs are also available. The CN8200 offers a wide range of options, including RS-232 and RS-485 digital communications, five remote analog setpoint ranges, three contact/digital input modes, four transducer excitation voltages, and four auxiliary output ranges.
Eight-level ramp/soak control consisting of 8 ramps and 8 soaks is standard, and includes a decimal display on thermocouple ranges, digital display and signal filtering, and a percentage of power limit setting. The dual control outputs can be configured for a variety of control and alarm applications, and two dedicated alarm outputs are also available. The CN8200 offers a wide range of options, including RS-232 and RS-485 digital communications, five remote analog setpoint ranges, three contact/digital input modes, four transducer excitation voltages, and four auxiliary output ranges.
PDFs & Manuals
Software & Drivers
Show Ratings & Reviews
Rated 5 out of
5
by
PTElectrical from
A+
Great experience. Quick shipping. Item as described.
Date published: 2023-03-12
Rated 5 out of
5
by
Bobby100 from
Great Product
Great Product! Thanks for your quality work Omega!
Date published: 2022-01-31
Rated 4 out of
5
by
mybeer2018 from
Confusion
You should have shipped all 5 units together instead of splitting the order. No explanation provided. That just caused unnecessary confusion.
Date published: 2021-04-19
How do you access the jumpers for current input on a CN8200
Hi KarenCT,
Thank you for the inquiry. Manual pg 19 illustrates jumper positions.
https://assets.omega.com/manuals/M2942.pdf
To access the jumpers the outer shell will need to be removed. Clear the terminal blocks, press in at detents, and slide the shell towards the back.
Best regards,
OMEGA
Date published: 2023-02-06
Do you have software that supports Windows 7/10?
Microsoft offers the "Windows XP Mode" emulator you can download and install from Microsoft.com. This will allow you to install and run the product software. There is no software update available for this product.
Date published: 2019-09-25
Do you have software for CN8201 compatible with MAC OS?
Thank you for your inquiry Olaf. Unfortunately, all the software available for the CN8201 is only compatible with Windows operating systems.
Date published: 2024-06-06
Do you have software for CN8201 compatible with 64bit Windows OS?
Hi Olaf,
Thank you for the inquiry. This is a legacy controller. We do not have software revised for Windows 10.
Best regards
OMEGA
Date published: 2022-08-26
After downloading this software onto Windows XP, it requires a User ID and password to log onto Multi-Comm. What User ID and password should we use?
Thank you for your inquiry. Please email your request to temp@omega.com and we will review and advise.
Date published: 2020-12-11
If you do not support the current Windows OS, can you help with Matlab or Labview codes that connect to the controller based on RS232 communication?
Hi Olaf,
Thank you for the inquiry. Manuals for the CN8200 series include the serial command set. This may be useful to you. We do not offer example code for 3rd party software though.
Best regards
OMEGA
Date published: 2022-08-31