PHE-6510
Submersible Flat Surface pH Electrodes
- 16 Month Shelf Life
- CPVC or PVDF Construction
- Designed For Mounting in Tanks, Flumes, etc
- Easy Mounting in Tanks
Product Overview
- Construction Type N/A
- Diameter 0 mm
- Electrical Connection N/A
- Enclosure Material PVDF
- Length 0 mm
- Mounting Orientation 45°
- PH Measurement Range 0 to 14.00 pH
- Process Connection Size 1/2 in
- Process Connection Type NPT Male
- Process Temperature, Max 65 °C
- Sensor Type N/A
- Temperature Note Specifications Maximum Temperature Standard Models: 65°C (150°F) “-ACRYL” Units: 87°C (190°F) CPVC body 100°C (212°F) PVDF body
- Temperature Sensor Type N/A
The OMEGA® PHE/ORE-6510 Series submersible electrodes are designed for use in drums, open tanks and streams, etc. The flat sensing surface is surrounded by a porous polyethylene reference junction which minimizes fouling. Electrode installation and removal done by a simple 1/4 turn quick disconnect. The cable assembly's cap has 1/2" MNPT thread, which can be connected to a coupling and support pipe. The pipe allows easy mechanical mounting and protects the cable from the liquid measured. The resulting assembly is lightweight for convenient handling when maintenance is needed. ATC is available as part of the mounting assembly.
The flat surface design is well suited for applications with relatively high suspended solids or where flocculation operations require low velocities.
Where only low velocities are present and coating is a problem, the electrode can be mounted at a 45 ° angle facing the flow so as to obtain increased scrubbing action across the measuring surface.
Note: At the time of initial purchase, please order both electrode and mounting assembly. Mounting assembly includes assembly in which the electrode is mounted and 10' cable. If ordered with automatic temperature compensation (ATC), the temperature compensator is built into the mounting assembly. When the electrode has expired, simply re-order the electrode (the mounting assembly is re-usable).
The flat surface design is well suited for applications with relatively high suspended solids or where flocculation operations require low velocities.
Where only low velocities are present and coating is a problem, the electrode can be mounted at a 45 ° angle facing the flow so as to obtain increased scrubbing action across the measuring surface.
Note: At the time of initial purchase, please order both electrode and mounting assembly. Mounting assembly includes assembly in which the electrode is mounted and 10' cable. If ordered with automatic temperature compensation (ATC), the temperature compensator is built into the mounting assembly. When the electrode has expired, simply re-order the electrode (the mounting assembly is re-usable).