  • Programmable Transmitter
  • M12 Connection
  • 4 to 20 mA Output = 0 to 100°C Default Setting
  • -50 to 120°C (-58 to 248°F) Full Programmable Range
M12TXSS
À partir de AUD 285.51
Modèles en stock
Stainless Steel RTD probes with 4 to 20 mA analog output & Mounting Threads M12TXSS M12TXSS
loading all models
Aperçu du produit
  • Accuracy Class A
  • Accuracy Detail Class A per IEC60751
  • Body Material Stainless Steel AISI 316L
  • Downscale 3.6 mA
  • Electrical Output 4 to 20 mA
  • EMC In accordance to EN 61326
  • Enclosure Ratings IP67
  • Enclosure Ratings Note IP65 and IP67 in accordance to IEC60529
  • Factory Setting 0 to 100°C/ sensor break >21 mA (upscale)
  • Operating Temperature, Max 80 °C
  • Operating Temperature, Min -40 °C
  • Permissible Load 700
  • Permissible Load Note 700 @ 24 Vdc [RLo= (Vsupply-8.5)/0.020]
  • Probe Diameter 3 mm
  • Process Temperature, Max 120 °C
  • Process Temperature, Min -50 °C
  • Range Configurations Note It is possible set the input temperature range (span) by the M12TX-CONFIG-SETconfiguration kit (PC with OS Windows® required)
  • Relative Humidity, Max 1
  • Relative Humidity, Min 0%
  • Response Time < 50 ms
  • Response Time Note Diameter 3 mm (0.12") <3.5 seconds, diameter 6 mm (0.24") <13 seconds (test in water to IEC751- time for reaching 63.2% of instantaneous temperature change)
  • RTD Type 100 Ω Pt Sensor
  • Sensor Break Monitoring Note Selectable: Upscale (>21.0 mA) or downscale (<3.6 mA) action Sensor Short-Circuit: Fixed to downscale (<3.6 mA) action
  • Sensor Error Compensation Note Over 2 points (maximum 1% of span)
  • Series ID M12TXSS
  • Span, Min 50°C
  • Span Note 50°C (122°F) [if the zero value is set between one of these values: -40°C (-40°F), -20°C (-4°F), 0°C (32°F), 20°C (68°F), 40°C (104°F), the minimum span is 20°C (68°F) rather than 50°C (122°F)]
  • Supply Power Effects Negligible
  • Supply Voltage 8.5 to 32 Vdc
  • Temperature Influence, Max ± 0.3%
  • Temperature Influence Note Maximum of ± 0.3°C/25°C (77°F) or ± 0.3% of span/25°C (77°F)
  • Temperature Sensor Type RTD
  • Thermocouple Type N/A
  • Tmax. Electronic 80°C
  • Upscale 21 mA
  • Zero Setting Adjustable Range Any value between -50 to 50°C (-58 to 122°F)

Supported Applications

The Omega M12TXSS series consists of stainless steel RTD temperature transmitters designed for compact installations where space is limited. These devices integrate a Pt100 sensor with an analog transmitter to provide direct process monitoring in industrial environments requiring secure, threaded mounting.

  • Temperature measurement and signal conditioning via 4 to 20 mA output
  • Applications utilizing M12 male connector interfaces for electrical connection

Operating Conditions & Performance

The series is engineered for a process temperature range of -50 to +120°C (-58 to 248°F). The electronic section operates within an ambient temperature range of -40 to +80°C. Accuracy specifications include Class A sensor performance in accordance with IEC751 and a transmitter accuracy maximum of ±0.2°C or ±0.2% of span.

  • Response time: <3.5 seconds for the 3 mm diameter probe (tested in water to IEC751, reaching 63.2% of thermal gap)
  • Enclosure rating: IP65 and IP67 in accordance with IEC60529
  • Humidity tolerance: 0 to 100% relative humidity

Configuration Options

The M12TXSS series offers configurable parameters via the M12TX-CONFIG-SET kit, which includes a USB interface and software for Windows®. The transmitter supports input temperature range configuration between -50°C to 800°C (span), sensor break monitoring selection (upscale or downscale action), and measurement unit settings.

  • Probe lengths: 13 mm (0.51") or 24 mm (0.94"); diameter is fixed at 3 mm (0.1")
  • Housing material: Stainless steel AISI 316L with a thermowell construction
  • Process connections: Standard 1/8" NPT male thread or G1/8 metric thread options
  • Electrical output: 4 to 20 mA signal; permissible load is 700Ω @ 24 Vdc (calculated as R_load = (U - 8.5) / 0.022)
  • Power supply: 8.5 + 32 Vdc with polarity protection

Key Product Differences

The series is distinguished by probe insertion length and thread standard, resulting in specific model configurations:

  • M12TXSS-PT100-13MM variants: 13 mm (0.51") long with either 1/8" NPT or G1/8 threads
  • M12TXSS-PT100-24MM variants: 24 mm (0.94") long with either 1/8" NPT or G1/8 threads

Factory default parameters are set to a range of 0+150°C for most models, though the M12TXSS series defaults to 0+100°C (32 to 212°F) with upscale sensor break indication (>21 mA). The device is non-isolated and features an M12 male connector output.

Accessoires

accessories

Accessoire pour configurer les appareils de la série M12TX via un PC sous Windows 10 ou version supérieure et le logiciel TTX-Platform
C$673.65 / each
2 En stock
Kit de configuration pour M12TX, interface série USB, câbles de connexion, logiciel de programmation pour Windows®
C$487.23 / each
0 En stock
Cet article est discontinué. Veuillez contacter l'équipe des ventes techniques pour assistance.

cables

Câbles M12 avec connecteurs montables sur site pour capteurs de résistance (RTD)
C$156.17 / each
2 En stock
Câbles M12 avec connecteurs montables sur site pour capteurs de résistance (RTD)
C$95.84 / each
0 En stock
fr-CA
en_AU
Enregistrer la configuration