Besoin d'aide? Appelez-nous: 1-800-663-4209
HHM-MA1500
1500A 1 RMS AC/DC Zangenamperemeter und berührungslose Spannungsmessung
Choisir une variante
Ajouté à votre panier
Configuration complète.
Veuillez ajouter au panier pour la conserver ou quitter la configuration
Veuillez ajouter au panier pour la conserver ou quitter la configuration
Échec de l'enregistrement des configurations, cliquez sur le bouton Configurer pour recommencer
Spécifications du produit
<< Voir tous les modèles de produit| Marque |
|
| AC Response | True RMS (AAC and Vac) |
| Additional Features 1 | 1500 A max Current |
| Altitude,Max | 2000 m |
| Auto Power Off | After approx. 30 minutes |
| Bandwidth | 50 to 400 Hz (AAC and Vac) |
| Battery Indication | Displayed |
| Capacitance | 400.00nF, 4000nF, 40.00μF, 400.0μF, 4.000mF, 20.00mF, 40.00mF |
| Capacitance Accuracy | ±(3.5%+10d) |
| Capacitance Resolution | 0.01nF |
| Clamp Jaw Opening Length | 52 mm |
| Continuity Test | Threshold 25 to 60Ω; Test current < 0.5mA |
| Crest Factor | 3.0 in 400A range, 1.4 in 1000A range — — (50/60 Hz and 5% to 100% of Range |
| Current Accuracy | ±(2.8%+30d) / ±(2.5%+30d) |
| Current Measurement Range | 40 A,1500 A |
| Current Resolution | 0.01A/0.01A |
| Diode Test | Test current of 0.3mA typical; Open circuit voltage 2.8 Vdc typical |
| Display Range | Dual 40000/4000 |
| Display Type | Backlit LCD |
| Duty Cycle | 10.0 to 95.0% |
| Duty Cycle Accuracy | ±(1.0%+2d) |
| Duty Cycle Resolution | 0.001 |
| Frequency | 40 Hz to 40 MHz |
| Frequency Accuracy | ±(0.3%+2d) |
| Frequency Resolution | 0.001Hz |
| GrossWeightValue | 1.95 |
| Height | 294 mm |
| Impedance Input | 10MΩ (Vdc and Vac) |
| Length | 47 mm |
| Measurement Type | AC/DC Voltage/Current, Resistance, Capacitance, Frequency, Type K Temperature |
| Measuring Temperature Range, Max | 1000 °C |
| Measuring Temperature Range, Min | -100 °C |
| Operating Humidity | 0 to 80% RH |
| Operating Temperature, Max | 40 °C |
| Operating Temperature, Min | 5 °C |
| Resistance | 40 MΩ |
| Resistance Accuracy | ±(0.5%+9d) |
| Resistance Resolution | 0.01Ω |
| Sampling Rate | 2 Hz (2 updates/second) |
| Series ID | HHM-MA1500-Clamp--Meter |
| Storage Humidity, Max | < 80 % |
| Storage Temperature, Max | 60 °C |
| Storage Temperature, Min | -20 °C |
| Supply Power Type | Battery |
| Temperature Resolution | 0.1 °C |
| Thermocouple Type | K |
| Voltage Accuracy | plus_minus_1_0_ptc_plus_30d_plus_minus_0_1_ptc_plus_4d |
| Voltage Measurement Range | 400 mV, 4 V, 40 V, 750 Vac, 1000 Vdc |
| Voltage Resolution | 0.01 mV/0.01 mV |
| Weight | 536 g |
| Width | 105 mm |
| measurement-type | AC/DC Voltage/Current, Resistance, Capacitance, Frequency, Type K Temperature |
| Pays d'origine | China |
| Voir toutes les spécifications | |