日本 +81 3 6822 0370 | 新しいウェブサイトへようこそ。問題やバグを見つけましたか?こちらからご報告ください
Series-TVA
高純度および腐食性液体用フッ素樹脂流量計、0-10スケール
- 化学的に不活性な接液部品により、腐食性液体アプリケーションでも長寿命を実現
- 標準の背面プロセス接続により、パネル取り付けが容易で設置コストが低減
製品の概要
- 精度 ± 5 %
- 精度の詳細 ± 5% FS @ 70 °F (21.1 °C) および 14.7 psia (1 atm 絶対圧)
- ガス流量(最大) 0 m³/s
- 真空下でのリーク率 10⁻⁷ cc He/s未満
- 材料建設オプション 該当なし
- 材料、湿潤 PCTFE(ポリクロロトリフルオロエチレン), ポリウレタン
- 対応媒体 プロセス水/冷却水
- 取付方向 垂直方向
- 動作温度(最高) 250 °F
- 圧力タイプ ゲージ
- プロセス接続タイプ NPT メス
- 耐圧力 最大 100 psi
- 繰り返し精度 ± 0.25%
- シリーズID Series-TVA
- ターンドダウン比 10:1
Supported Applications
The Dwyer Series TVA All Fluoropolymer Flowmeters are variable area flowmeters designed for high purity or corrosive liquid applications. These instruments feature chemically inert wetted components, making them suitable for service with compatible liquids where corrosion resistance is required.
Operating Conditions & Performance
The Series TVA operates within a maximum process temperature of 250°F (121°C) and a pressure limit of 100 psig (6.9 bar). However, the maximum allowable service pressure decreases as the service temperature increases; for example, at 60 psig (4.2 bars), the maximum allowable temperature must not exceed 70 deg C (158 deg F).
Performance specifications include an accuracy of ±5% FS @ 70°F (21.1°C) and 14.7 psia (1 atm absolute) with a repeatability of ±0.25%. The series offers a 10:1 turndown ratio and maintains leak integrity at 1 x 10⁷ sccs of helium.
Maximum Allowable Pressure vs Temperature
- 100 psig (6.9 bars) @ 20°C (68°F)
- 80 psig @ 40°C (104°F)
- 60 psig @ 60°C (140°F)
- 40 psig @ 80°C (176°F)
- 20 psig @ 100°C (212°F)
- 0 psig @ 120°C (248°F)
Flow Ranges by Model Family
The series provides direct reading scales with discrete flow rate graduations on a 0 to 10 scale. Available water flow ranges include:
- Low Range Models (75 mm length): Flow rates from 6.34 GPM (400 L/min) up to 79.2 GPM (5000 L/min).
- High Range Models (125 mm length): Flow rates from 3.43 GPM (13 L/min) up to 11.9 GPM (45 L/min).
Configuration Options
The Series TVA is available in two primary lengths: 75 mm and 125 mm, with back-connect process connections ranging from 1/4" to 3/4" female NPT. Models are offered with or without built-in valves positioned at the outlet unless otherwise specified.
Wetted Materials
- Fluwtube: PFA (Teflon)
- Float and end fittings: PTFE
- Guide rods: PCTFE
Mounting and Installation Options
The flowmeters must be installed in a vertical position; significant deviation from vertical will affect the flow readings. Panel mounting requires specific hole diameters based on connection size: 3/4" dia for 1/4" NPT models, 7/8" dia for 3/8" NPT models, 1" dia for 1/2" NPT models, and 1-1/4" dia for 3/4" NPT models.
Options
- NIST traceable calibration certificate for variable water flowmeters (Order Code: NISTCAL-FL2)
Key Product Differences
The series distinguishes between Low Range and High Range models based on length, connection size, and specific flow capacity. Model numbers follow the pattern TVA<MODEL>-<VALVE_OPTION>-<LENGTH>-<CONNECTION_SIZE>.
- TVA11XX Series: 75 mm length with 1/4" female NPT connections.
- TVA13XX Series: 75 mm length with 3/8" female NPT connections.
- TVA22XX Series: 125 mm length with 1/2" female NPT connections.
- TVA24XX Series: 125 mm length with 3/4" female NPT connections.
Within each model family, variants are available "With Valve" or "Without Valve." For example, the TVA1103 is a 75 mm unit without a valve, while the TVA1113 includes a built-in outlet valve. Disassembly of PFA/Teflon flowmeters is not recommended; critical sealing surfaces and O-rings can be damaged if taken apart.