Netherlands 07077 03815 | Intl +31 (0) 7077 03815 | Welcome to our new site - found a bug? Please report it here
FLR1600-Series
Stainless Steel Low Flow Flow Meters and Controllers
- Response Time of 20 milliseconds Typical (Meter)
- Turndown Ratio of 50:1
- Push Button Tare (with Display)
- Accuracy of ± 2% Full Scale
FLR1600-Series
From
€
2.007,66
Product Overview
- Accuracy ± 2 %
- Calibration NIST Certificate
- Data Interface RS232
- Display Type LCD
- Electrical Connection 8-pin mini DIN
- Electrical Output 0 to 5 V
- Excess Flow Rate Approx 28% overage
- Height 4.4 in
- Length 2.4 in
- Materials, Wetted 302 Stainless Steel, 303 Stainless Steel, 316 Stainless Steel, FKM, Polythermide, Silicone
- Media Compatibility Alcohol, Liquids, Oil, Water
- Operating Pressure, Min 0 psi
- Operating Temperature, Max 50 °C
- Operating Temperature, Min 10 °C
- Pressure Drop, Min 0.4 psi
- Response Time 20 ms
- Span Shift 0.02%/ATM FS/°C
- Turndown Ratio 50:1
- Volumetric Flow Rate, Min 0.001 cm³/min
- Width 1.05 in
The OMEGA Series FLR-1600A and FLV-4600A series flow meters and controllers use two of the best studied physical properties of liquids to measure flow: Pressure and Viscosity. Differential pressure measurement, across a laminar flow element, results in a flow meter that is inherently linear. OMEGA flow meters measure differential pressure within that laminar region to achieve a turn-down of 50:1 typical and the accuracy is ± 2.0% of full scale. It uses the same technology as the laminar gas mass flow and volumetric flow meters, FMA-1600A and FLV-1600A. There are no moving parts to wear out.
The FLR-1600A Series is a Volumetric Water Flow meter. The unique method of flow detection allows the meter to measure extremely low flow rates at an affordable price. The FLR-1600A Series was designed with deionized water in mind. These flow meters are available in ranges of 500 micro-liters per minute full scale to 10 liters per minute full scale.
The FLR-1600A water meter provides data on the flow rate and temperature via the standard local display and the RS232 serial output. An optional gauge pressure sensor is available on the secondary output model "-P".
The FLV-4600A Series Water Flow Controller utilizes a proportional valve coupled to a flow meter body creating a unique in-situ closed-loop flow controller system. Measurements are taken within the laminar region of the flow meter and the integral PID controller positions the valve according to the flow set points. The controllers can accept an RS-232 or the 0-5 Volt control input signal depending on what is preferred. Independent of the set point voltages, the controllers can be configured for single or dual output of the same or different voltages and/or different parameters such as temperature and flow. This is possible because of our laminar flow meter design that incorporates solid-state Differential and Temperature Sensors on the standard model to determine flow in an inherently linear system. An optional , an Absolute Gauge Pressure Sensor is available on the "-P" secondary output models. The result is a fast responding linear flow meter with multiple outputs. All these parameters are simultaneously visible with our dynamic display that includes a push button operator interface. Water flow controllers are available from 50 milliliters per minute full scale to 500 milliliters per minute full scale.
The FLR-1600A Series is a Volumetric Water Flow meter. The unique method of flow detection allows the meter to measure extremely low flow rates at an affordable price. The FLR-1600A Series was designed with deionized water in mind. These flow meters are available in ranges of 500 micro-liters per minute full scale to 10 liters per minute full scale.
The FLR-1600A water meter provides data on the flow rate and temperature via the standard local display and the RS232 serial output. An optional gauge pressure sensor is available on the secondary output model "-P".
The FLV-4600A Series Water Flow Controller utilizes a proportional valve coupled to a flow meter body creating a unique in-situ closed-loop flow controller system. Measurements are taken within the laminar region of the flow meter and the integral PID controller positions the valve according to the flow set points. The controllers can accept an RS-232 or the 0-5 Volt control input signal depending on what is preferred. Independent of the set point voltages, the controllers can be configured for single or dual output of the same or different voltages and/or different parameters such as temperature and flow. This is possible because of our laminar flow meter design that incorporates solid-state Differential and Temperature Sensors on the standard model to determine flow in an inherently linear system. An optional , an Absolute Gauge Pressure Sensor is available on the "-P" secondary output models. The result is a fast responding linear flow meter with multiple outputs. All these parameters are simultaneously visible with our dynamic display that includes a push button operator interface. Water flow controllers are available from 50 milliliters per minute full scale to 500 milliliters per minute full scale.
PDFs & Manuals