FMA4000-Series
Programmable Mass Flow Meter and Totalizer
Models In Stock
- 23 Selectable Engineering Units (Including User Defined)
- Programmable Totalizer
- High and Low Gas Flow Alarms
- Two Sets Programmable SPDT Relays with Latching Feature
FMA4000-Series
From
€
1.042,39
Models In Stock
Product Overview
- Accuracy ± 1 %
- Accuracy Detail ± 1% of FS at calibration temperature and pressure
- Altitude Sensitivity Deviation of up to 1% from stated accuracy, after re-zeroing
- Calibration NIST 10-Point Certificate
- Data Interface RS232
- Electrical Output 4 to 20 mA, 0 to 5 Vdc
- Enclosure Ratings Inst. Level II/Poll. Degree II (IEC 60664)
- Humidity Range Up to 70%
- Leak Rate Under Vacuum less than 10^⁻9 cc He/s
- Materials, Wetted 316 Stainless Steel, Aluminum, Brass, FKM
- Operating Pressure, Max 500 psi
- Operating Pressure, Min 0 psi
- Operating Temperature, Max 50 °C
- Operating Temperature, Min 5 °C
- Output Detail Linear 0 to 5 Vdc (3000 Ω min load impedance); Linear 4 to 20 mA (500 Ω max loop resistance). Max noise 20 mV peak to peak (for 0 to 5 Vdc output)
- Output Signal Current, Voltage
- Power Consumption 2.4 W
- Pressure Coefficient 0.01% FS/psi
- Process Connection Type Compression Fitting
- Repeatability ± 0.15%
- Response Time 2 sec
- Response Time Note 600 ms time constant; approximately 2 seconds to within ± 2% of set flow rate for 25 to 100% of full scale flow
- Supply Power Note Transducer Input Power: 11 to 26 Vdc, 100 mV max peak to peak output noise
- Supply Voltage 11 to 26 Vdc
- Switch Rating 30 Vdc, 1A
- Switch Type SPDT NO/NC, Selectable
- Temperature Coefficient 0.15% FS/°C
- Turndown Ratio 50:1
- Volumetric Flow Rate, Min 0.1 SCCM
The FMA-4100/4300 Series flow rate can be displayed in 23 different volumetric flow or mass flow engineering units including a user specific selection. Flowmeters can be programmed remotely via RS232 or RS485 (optional). FMA-4100/4300 flowmeters support various functions including, programmable flow totalizer, high and low flow alarm, automatic zero adjustment, 2 relay outputs, jumper selectable 0 to 5 Vdc or 4 to 20 mA analog outputs, status LED diagnostic, storage of up to 10 different gas calibrations, internal or user-specific K-factors. Display models have local 2 lines x 16 characters LCD display with adjustable back light provides flow, total and diagnostic reading simultaneously. The digital RS232 or RS485 (optional) interface provides access to applicable internal data including, flow, CPU temperature, auto zero, totalizer and alarms settings, gas table, conversion factors and engineering units selection, dynamic response compensation and linearization table adjustment. The analog interface provides 0 to 5 Vdc or 4 to 20 mA (jumper selectable) outputs for flow reading.
The FMA-4100/4300 supports automatic sensor zero offset adjustment which can be activated locally via the maintenance push button or remotely via digital interface. The auto zero feature necessitates a condition of absolutely no flow through the meter during the adjustment process. Provisions are made to either start, read, or save the current auto zero value via digital commands. Digital totalizer commands include: set to zero, start at a preset flow, assign action to a preset value, start/stop totalizing and read. High and Low gas flow alarm limits can also be preprogrammed via digital interface. Alarm action can be assigned with preset delay interval (0 to 3600 seconds) to activate the contact closer (separate for high and low alarm). Latch mode control feature allows each relay to be latched on or follow the corresponding alarm status.
FMA-4100/4300 Transducers should not be used for monitoring Oxygen gas unless specifically clean and prepared for such application. See below for ordering instructions.
The FMA-4100/4300 supports automatic sensor zero offset adjustment which can be activated locally via the maintenance push button or remotely via digital interface. The auto zero feature necessitates a condition of absolutely no flow through the meter during the adjustment process. Provisions are made to either start, read, or save the current auto zero value via digital commands. Digital totalizer commands include: set to zero, start at a preset flow, assign action to a preset value, start/stop totalizing and read. High and Low gas flow alarm limits can also be preprogrammed via digital interface. Alarm action can be assigned with preset delay interval (0 to 3600 seconds) to activate the contact closer (separate for high and low alarm). Latch mode control feature allows each relay to be latched on or follow the corresponding alarm status.
FMA-4100/4300 Transducers should not be used for monitoring Oxygen gas unless specifically clean and prepared for such application. See below for ordering instructions.