OM-240-Logger
Omega 24-Channel Ethernet Data Logger with Embedded Web Server
- Omega Enterprise Gateway Compatible
- 24 Differential, Independent Analog Input Channels, 2 Digital Inputs and 1 Digital Output
- On-Board Web Server for Setup, Data View, and Diagnostic
- Independent Thermocouples, PT100/200/500/1000, NTC, mV, mA, mV/V, Vibrating Wire
OM-240-Logger
From
€
3.803,89
Product Overview
- Alarm Note Max Input Voltage: 24V (max current: 10mA), Min Input Voltage: 5V (max current: 2mA), Measurement Rate: max frequency 1 kHz, Accuracy: 0.1 Hz, Two opto-isolated digital inputs individually selectable for switch closure. One relay output (for alarm, etc.): volt-free closure (low voltage 30V, 2A)
- Baud Rate 9600 to 115200
- Configuration WindowsPC Software, Independent OS Platform
- CPU and Memory Processor ARM Cortex-M3 MCU with 1 MB Flash, 120 MHz CPU, ART Accelerator, Ethernet
- Current Accuracy 0.0001
- Current Measurement Range 4 to 20 mA
- Data Interface Ethernet, RS485, RS232, USB
- Data Interface Note LAN Ethernet: 10/100 Mbps, RJ45, Isolated RS232: 9-pin, DE9. DCE port for optional GSM/GPRS modem connection Baud Rates: selectable from 9600 bps to 115.2 kbps Default Format: 8 data bits; 1 stop bits; no parity USB: USB 2.0 pen drive only (FAT 32), 5 V 200 mA RS485#1 AND RS485#2 Connection: 5 screw clamp port for max. No.254 Modbus RS485 digital bus sensors Communication Interface: RS485 - Optoisolated Communication Protocol: MODBUS RTU
- Display LCD
- Display Note Small backlight graphic LCD 128 x 64 dpi with membrane keyboard for the minimal local management without the PC. Keyboard for starting a data acquisition scan, sequential display of the last stored readings for each channel (sensor ID, converted unit reading, unit of measure), device status, data download and firmware/Web pages update by USB pen drive, safe mode (back-up/format/restore internal SD card).
- External Sensor Range Thermocouple: K -200 to 1370°C, B 600 to 1820°C, J -200 to 1200°C, T -200 to 400°C, E -200 to 1000°C, R -20 to 1760°C, N -260 to 1300°C, S -20 to 1760°C, Thermistor: -50 to 150°C
- Height 9.09 in
- Impedance Input 20 MΩ
- Input Noise Voltage 5.42 µV pp
- Input Type External
- Length 4.61 in
- Current, Max 5 A
- Measurement Type Current, Strain, Temperature, Voltage
- Memory 1 MB RAM, 2 GB SD card
- Memory Note 2 GB SD card for data (about 5 Mega data points) and Web pages
- Operating Temperature, Max 60 °C
- Operating Temperature, Min -30 °C
- Relative Humidity 80% RH
- Resolution Note Thermocouple Resolution: 1 µV at FS for ± 10 mV range; 10 µV at FS for ± 100 mV range; 100 µV at FS for ± 1 V range, Voltage Resolution: ± 10 mV: 1 µV at FS, ± 100 mV: 10 µV at FS, ± 1 V: 100 µV at FS, ± 10 V: 10 mV at FS
- RTD Type 100/200/500/1000Ω Pt sensor
- Samples,Max 5M Samples, Interval 1 Sec up to 1 Week
- Sensor Type Thermocouple, RTD, Thermistor
- Software Packages Acquisition Time Interval: Selectable from 1 second up to 1 week (depends on the number of channels acquired) FTP client: To send data/alarms on an FTP server (SFTP not supported) MAIL to send data/alarm: To max 5 email address (SMTPS / SSL not supported) SMS to Send Alarms: To max 5 telephone numbers Data Download: (measure, logs) in .csv file (compatible with Microsoft Excel) Virtual Channels Management: For Math operations between channels
- Storage Temperature, Max 85 °C
- Storage Temperature, Min -40 °C
- Supply Power Note 10 to 30 Vdc (reverse polarity protected), max 5A, RTD Power Supply: 1.2mA, Thermistor Power Supply: 0.05mA, 0.1mA, 1.2mA, Voltage Power: 5V, 10V, 20V, 24V DC*, Current Power: 10V, 24V DC*, Wheatstone Bridge Power Supply: ± 10 mV/V, External Rechargeable Batteries: 12 Vdc nominal, Switched Output Power Supply: The voltage ‘V OUT’ is switched on and off under program control. V OUT is the unregulated input power supply ‘V IN’ (2 A Max)
- Supply Power Type DC
- Supply Voltage 10 to 30 Vdc
- Temperature Accuracy Thermocouple: K: ± 1,99 °C, B: ± 1,22 °C, J: ± 1,04 °C, T: ± 1,99 °C, E: ± 0,93 °C, R: ± 1,64 °C, N: ± 1,24 °C, S: ± 1,64 °C, RTD: 0.17%, Thermistor: -50 to 0°C: ± 2 °C, 0 to 150°C: ± 1 °C
- Temperature Sensor Drift < 10 ppm/°C, range -30 to 70°C
- Thermistor Type 3000 Ω @25 °C, NTC
- Thermocouple Type J, K, T, E, R, S, B, N
- Voltage Accuracy 0.01%, On-Board: ± 1%, Wheatstone Bridge: 0.01%
- Voltage Measurement Range ± 10 mV, ± 100 mV, ± 1 V, ± 10 V, Wheatstone Bridge: ± 10 mV/V
- Weight 2.16 lb
- Width 5.43 in
OM-240 is a versatile, high accuracy “smart” data acquisition system. It provides 24 differential analog inputs, individually configured. The Data Logger can be used in a wide range of applications, including HVAC, oil and gas, water quality, energy and building monitoring. Using OM-240 requires no additional configuration/analysis software package, as it is provided by an Embedded Web Server. Only a standard Web Browser (Firefox recommended) for configurations and data view. Logged Data is ready to be shown in a graphic “real time” mode (License required) or exported in a CSV file. Channel expansion provided by multiplexers. There are 8 terminal blocks (each terminal block can handle up to 3 sensors). The OM-240 is designed to work with 2 to 6-wire sensors. You can connect 2-wire sensors on each channel and read 24 sensors, or 4-wire sensor and read 12 channels. The system will order sensors depending on how many wires they use, placing 6 wires sensors first, 4 wires in the middle, and 2 wires last.
Once software configuration is done, clicking on “Wiring scheme” button on the web interface near the sensors will show how to connect the chosen sensor to the block physically. It shows “relative” position, so if you start connecting sensors from the first, you will not have to leave “unused” positions (except for the ground connection of every block, if not used). Multiplexers are needed if the total “wires” from sensors exceeds the 48 provided by the OM-240.
Applications including Oil/Gas Pipeline Monitoring, Building/Bridge Structure Health Monitoring, Engine Thermal Mapping Testing, Data Center Environmental Monitoring, and Energy Farm Monitoring, and etc.
Once software configuration is done, clicking on “Wiring scheme” button on the web interface near the sensors will show how to connect the chosen sensor to the block physically. It shows “relative” position, so if you start connecting sensors from the first, you will not have to leave “unused” positions (except for the ground connection of every block, if not used). Multiplexers are needed if the total “wires” from sensors exceeds the 48 provided by the OM-240.
Applications including Oil/Gas Pipeline Monitoring, Building/Bridge Structure Health Monitoring, Engine Thermal Mapping Testing, Data Center Environmental Monitoring, and Energy Farm Monitoring, and etc.