Netherlands 07077 03815 | Intl +31 (0) 7077 03815 | Welcome to our new site - found a bug? Please report it here
FMA3000-Series
Mass Flow Controllers and Meters for All Clean Gases
- For Flowrates Up To 10,000 mL/Min
- 0-5 Vdc Linear Output
- Cost Effective
FMA3000-Series
From
€
469,41
Product Overview
- Accuracy ± 1.5 %
- Additional Features 1 Requires 20-micron filter
- Electrical Output 0 to 5 V
- Enclosure Ratings IP10
- Height 3.5 in
- Leak Rate Under Vacuum less than 10^⁻4 cc He/s
- Length 1.87 in
- Media Compatibility Air, Gases, Nitrogen, Oxygen
- Operating Pressure, Min 0 psi
- Operating Temperature, Max 50 °C
- Operating Temperature, Min 10 °C
- Output Detail 0 to 5 Vdc (2500 Ω minimum)
- Output Signal Voltage
- Pressure Coefficient ± 0.02%/psi
- Pressure Drop, Max 1 inH₂O
- Process Connection Type Compression Fitting
- Repeatability ± 0.5%
- Response Time 2 sec
- Response Time Note 2 seconds (typical) to within ± 2% of actual flow rate from 25 to 100% of full scale
- Supply Current 100 mA
- Supply Voltage 12 to 15 Vdc
- Temperature Coefficient ± 0.2%/°C
- Turndown Ratio 10:1
- Volumetric Flow Rate, Min 2 SCCM
- Weight 0.44 lb
- Width 1.03 in
FMA3100 Series mass flow sensors represent a breakthrough in mass flow sensor technology. State-of-the-art electronics, a compact mechanical design, and mass production tooling concepts are combined into one high- performance, cost effective product. The gas flow sensor is suitable for many OEM applications. A 0 to 5 Vdc linear output is standard.
Using the basic FMA3100 thermal mass flow sensor, the FMA3200 mass flow controllers offer accurate, stable control of gas flows in a compact package. In power-off mode, the flow control valve is closed with a minimal leak rate. This cost-effective controller is ideal for many OEM applications, with a 0 to 5 Vdc linear output and a 0 to 5 Vdc control input.
The FMA3300s combine the features of the FMA3100 with an adjustable 3½ digit LCD digital display meter for viewing flow rate in engineering units (i.e., mL/min or L/min). These compact flow meters have proved effective in many laboratory applications.
Using the basic FMA3100 thermal mass flow sensor, the FMA3200 mass flow controllers offer accurate, stable control of gas flows in a compact package. In power-off mode, the flow control valve is closed with a minimal leak rate. This cost-effective controller is ideal for many OEM applications, with a 0 to 5 Vdc linear output and a 0 to 5 Vdc control input.
The FMA3300s combine the features of the FMA3100 with an adjustable 3½ digit LCD digital display meter for viewing flow rate in engineering units (i.e., mL/min or L/min). These compact flow meters have proved effective in many laboratory applications.
PDFs & Manuals