FMA1600-Series
Mass and Volumetric Flow Meters
Models In Stock
- Ranges of 0 to 0.5 SCCM Up to 0 to 3000 SLM
- < 10ms Response Time—Field Adjustable
- 130+ Gas Calibrations with Every Unit: Air, Ar, CH4, CO, CO2, Ethane, H2, He, N2, N2O, Neon, O2, Propane, Butane, Acetylene, Ethylene and more
- Pressure, Temperature, and Volumetic and Mass Flow Simultaneously Displayed
FMA1600-Series
From
€
1.584,01
Models In Stock
Product Overview
- Accuracy ± 0.8 %
- Accuracy Detail ± (0.8% of rdg + 0.2% FS)
- Additional Features 1 Power Supply Included
- Calibration NIST 5-Point Certificate
- Data Interface RS232
- Display Type LCD
- Electrical Connection 8-pin mini DIN
- Height 4.1 in
- Humidity Range 0 to 100% RH non-condensing
- Materials, Wetted Aluminum, Brass, Epoxy, FKM, Glass, Gold, Silicone, Stainless Steel
- Measurable Flow Rate 125%
- Media Compatibility Air, Gases, Nitrogen, Oxygen
- Operating Pressure, Max 145 psi
- Operating Pressure, Min 0 psi
- Operating Temperature, Max 50 °C
- Operating Temperature, Min -10 °C
- Pressure Drop, Min 1 psi
- Repeatability ± 0.2%
- Response Time 10 ms
- Response Time Note 10 ms typical default response time for 63.2% of a step change. A variable register allows response time to be field adjustable to a certain extent via RS232 communications. The primary trade-off for response time is signal noise
- Span Shift 0.02% FS/°C/atm
- Supply Current 35 mA
- Supply Power Note 35 mA typical current draw; 100 mA available supply recommended
- Turndown Ratio 200:1
- Volumetric Flow Rate, Min 0.05 SLM
- Width 1.1 in
The FMA-1600A Series mass and volumetric Omega's flow meters use the principle of differential pressure within a laminar flow field to determine the mass flow rate. A laminar flow element (LFD) insdie the meter forces the gas into laminar (streamlined) flow. Inside this region, the Poiseuille equation dictates that the volumetric flow rate be linearly related to the pressure drop along a fixed distance of the LFE. This, along with the viscosity of the gas, is used to accurately determine the volumetri flow rate. Separate absolute temperature and pressure sensors are incorporated and correct the volumetric flow rate to a set of standard conditions. This standardized flow rate is commonly called the mass flow rate and is reported in units such as standard cubic feet per minute (SCFM) or standard liters per minute (SLM).
Standard units include a 0 to 5 V output (4 to 20 mA optional) and RS232 communications. The gas select feature can be adjusted from the front of the keypad or via RS232 communications. Volumetric flow, mass flow, or absolute pressure, and temperature can be viewed or recorded through the RS232 connection. It is also possible to multi-drop up to 26 units on the same serial connection to a distance of 125'. These flowmeters are also available in a portable version for use in the field (-B models).
Standard units include a 0 to 5 V output (4 to 20 mA optional) and RS232 communications. The gas select feature can be adjusted from the front of the keypad or via RS232 communications. Volumetric flow, mass flow, or absolute pressure, and temperature can be viewed or recorded through the RS232 connection. It is also possible to multi-drop up to 26 units on the same serial connection to a distance of 125'. These flowmeters are also available in a portable version for use in the field (-B models).