Skip to search Skip to main content Skip to navigation

Netherlands 07077 03815 | Intl +31 (0) 7077 03815 | Welcome to our new site - found a bug? Please report it here

We noticed you are in , please visit your local site by clicking the below link for regional offers and support.

LCCD

IP67 Environmentally Protected S-Beam Load Cells

  • Environmentally Protected to IP67
  • All Stainless Steel for Industrial Environments
  • 5 Point Calibration with 59 kOhm Shunt Cal Data
  • Tension Calibration Standard
LCCD
From  673,88
IP67 Environmentally Protected S-Beam Load Cells LCCD LCCD
loading all models
Product Overview
  • 5-Point Calibration 0%, 50%, 100%, 50%, 0%
  • Bridge Resistance 350 Ω
  • Cable Length 20 ft
  • Calibration Option 5 POINT NIST
  • Creep in 20 min 0.0003
  • Electrical Connection Cable
  • Electrical Output 3 mV/V
  • Enclosure Ratings IP67
  • Force Type Compression, Tension
  • Hysteresis 0.0005
  • Interchangeability 0.0025
  • Load Cell Type S-beam
  • Materials 17-4 PH Stainless Steel
  • Operating Temperature, Max 66 °C
  • Operating Temperature, Min -18 °C
  • Overload, Max 300% FS
  • Process Temperature, Max 66 °C
  • Process Temperature, Min -18 °C
  • Repeatability 0.0001
  • Safe Overload 150% FS
  • Supply Power Note 10 Vdc, 15 Vdc maximum
  • Supply Voltage 10 Vdc
  • Thermal Span Effect 0.0015% rdg/°C
  • Thermal Zero Effect 0.0027% FS/°C
  • Wire Gauge 22 AWG
  • Wiring/Connector Table Green: (+) Output; White: (-) Output; Black: (-) Input; Red: (+) Input
  • Zero/Balance Error 0.01
The LCCD series IP67-rated S-beam load cells offer environmental protection and high precision with ±0.03% linearity and 0.0001 repeatability. They provide a 3 mV/V output and are available in capacities from 25 to 20,000 lbf, making them ideal for accurate force measurement in harsh conditions.

The LCCD is also available in metric configurations, with 0-10 to 0-5,000 kgf ranges and metric thread. Please see the LCMCD for complete details, or contact our Pressure department for more information.
en-NL
en_NL
Save Configuration