<< See all Product Models| Brand |
|
| Accuracy | ± 0.01 % |
| Accuracy Detail | ± 0.01% of reading ± 1 count of A/D @ 25°C (77°F) |
| Channels | One channel standard, second channel optional |
| Convert/Hold Input | Normally high; if pulled low, holds display |
| Cutout Dimensions | 2.45 x 5.06 in |
| Digital Filter | Programmable Cutoff Frequency |
| Display Note | -32768 to 32767 with programmable decimal points; 14 mm (0.56") red LED |
| Display Type | LED |
| Electrical Connection | Screw Terminal |
| Form factor | 1/8 DIN |
| Height | 2.7 in |
| Input Analog Filter | 4-pole active anti-alias; 500 Hz cutoff on single-channel unit and 250 Hz cutoff on dual-channel unit |
| Input Bias Current | ± 50 nA maximum ± 100 pA/°C (per input channel) |
| Input Configuration | Front Keypad |
| Internal Resolution | 16 bit |
| Length | 6.9 in |
| Measurement Type | Current, Strain, Voltage |
| Mounting | Panel |
| Number of Digits | 5 |
| Number of Inputs | 1 |
| Operating Temperature, Max | 60 °C |
| Operating Temperature, Min | -20 °C |
| Output Method | RJ11 jack for serial interface |
| Peak Detection | Updated at rate selected by digital filter, peak stored in memoryrogrammed to give limit #1 output up to 100 seconds after a programmed limit is reached. This output can be used to reset the peak reading by tying limit #1 output to remote input |
| Power Consumption | 8 W |
| Reading Rate | Limited to 1000/s divided by number of channels |
| Remote Inputs | Display Peak, Display Runout, Reading, Reset Peak, Runout Reading, Tare |
| Resolution | 16-bit A/D |
| Rollover Error | ± 2 counts of A/D @ 25°C (77°F) |
| Runout Mode | Updated at rate selected by digital filter. Runout is normally stored in memory and recalled via front-panel switch, over the serial interface, or by selecting runout display mode on rear connector. |
| Sampling Rate | 1000 Hz |
| Sensor Excitation | ± 15 Vdc, ± 5 Vdc @ ± 50 mA |
| SetPoint Outputs | 4 isolated opencollector transistor outputs rated 30 Vdc maximum; will sink up to 50 mA; 300 V isolation between limit outputs and system ground; limit #1 can be programmed to be delayed from 1 to 100 seconds |
| Settable Parameters | Digital Filter, Limits, Offset, Span |
| Weight | 370 g |
| Width | 5.18 in |
| See All Specs | |