TX400-Srs-RFID-Prog-Tx
Head Mount Temperature Transmitters with RFID Communications
TX400-Srs-RFID-Prog-Tx
From
€
66,03
Product Overview
- Approvals CE,EN 61000-6-4, EN 61000-6-2
- Calibration Wireless with RFID technology (NFC)
- Diameter 45 mm
- Electrical Connection Screw Terminal
- Electrical Output 4 to 20 mA
- Enclosure Ratings IP20, NEMA Type 1
- Height 23 mm
- Housing Material Nylon (PA66)
- Humidity Range 30 to 90% RH non condensing
- Lead Resistance, Max 20 Ω
- Mounting DIN/B Head
- Noise Rejection 50 to 60 Hz
- Operating Temperature, Max 85 °C
- Operating Temperature, Min -40 °C
- Probe Length 0 mm
- Programmable Functions offset, Range, Sampling Frequency, Sensor Burnout Indication, sensor type
- Protection Current 30 mA
- Resolution 1 μA
- Response Time 600 ms
- Sampling Time 300 ms
- Sensor Type Transmitter
- Setup Controls Wireless with RFID technology (NFC)
- Sheath Material N/A
- Software Windows® XP/7/8 (32-bit and 64-bit), Windows 10 (64-bit)
- Storage Temperature, Max 85 °C
- Storage Temperature, Min -40 °C
- Supply Power Note 2-wire loop powered; operating range 6 to 32 Vdc
- Supply Power Type DC
- Supply Voltage 6 to 32 Vdc
- Temperature Input Range Pt100: -200 to 800 °C; Pt1000: -200 to 800 °C; Ni100: -50 to 170 °C
- Transmission Error, Max 0.1% or 0.2°C
- Weight 30 g
The TX401 and TX402 head mount temperature transmitters transform a temperature signal acquired from a Pt100, Pt1000 (TX401 only) or Ni100 RTD sensor or from a thermocouple (TX402 only) into a linearized 2-wire loop-powered 4 to 20 mA output. The characteristics of these converters ensure high precision on the reading scale with 16-bit conversion. The 4 to 20 mA output can be scaled based on the desired temperature input range. The programming procedure uses an RFID (NFC) mode with the dedicated TX400-RFID programmer that allows the user to make all calibrations and settings quickly and without the need to power and connect up the transmitter. Simply connect the TX400-RFID programmer to the USB port of your PC, start the RF Programmer configuration software and place the transmitter on top of the TX400-RFID programmer to establish communications.
An additional programming tool is the Omega Brand Google App - "Direct Link" relying on RFID/NFC connectivity and allowing straightforward programming without wirings by Android devices.
These temperature transmitters are also provided with a data logging function for the input signal. Transmitters have a non-volatile memory (circular buffer) for data-logging with user-selectable sampling time. The user selects the sampling time (1 to 3600 seconds) and then each time the 4 to 20 mA loop powers the device, the input value is stored to nonvolatile memory.
Using the TX400-RFID programmer along with the RF Programmer configuration software (software is a free download from OMEGA) the user can:
• Completely configure the transmitter including scaling the 4 to 20 mA output to desired temperature input range
• Implement field calibration to compensate for gain and offset errors
• Download logged data to PC for visualization and printing
An additional programming tool is the Omega Brand Google App - "Direct Link" relying on RFID/NFC connectivity and allowing straightforward programming without wirings by Android devices.
These temperature transmitters are also provided with a data logging function for the input signal. Transmitters have a non-volatile memory (circular buffer) for data-logging with user-selectable sampling time. The user selects the sampling time (1 to 3600 seconds) and then each time the 4 to 20 mA loop powers the device, the input value is stored to nonvolatile memory.
Using the TX400-RFID programmer along with the RF Programmer configuration software (software is a free download from OMEGA) the user can:
• Completely configure the transmitter including scaling the 4 to 20 mA output to desired temperature input range
• Implement field calibration to compensate for gain and offset errors
• Download logged data to PC for visualization and printing