Netherlands 07077 03815 | Intl +31 (0) 7077 03815 | Welcome to our new website, found an issue or bug? Please report it here
OM-CP-OCTPRO
Eight Channels Programmable Portable Data Logger
Choose a Variant
Number of Channels
Added to Your Shopping Basket
Configuration complete.
Please add to basket to keep it or exit the configuration
Please add to basket to keep it or exit the configuration
Failed to Save Configurations, Click on Configure Button Start Again
Product Specs
<< See all Product Models| Brand |
|
| AC Power Plug Type | N/A |
| Accuracy | ± 0.1 % |
| Accuracy Detail | Current Accuracy: ±0.024 mA Voltage Accuracy: ±0.1 mV, ±0.01 V Thermistor Accuracy: ±0.50% RTD Accuracy: ±0.1 °C Thermocouple Accuracy: J, K, T, E, N: ±0.5 °C R, S, B: ±2.0 °C |
| Battery Size and Type | 3.7V Li-ion |
| Calibration | Factory calibration is recommended annually |
| Data Interface | USB |
| Dimensions Note | 6.65 in x 4.40 in x 1.41 in (168.9 mm x 111.8 mm x 35.8 mm) Data logger only |
| Display Note | LCD Touchscreen: 5 inch LCD capacitive touchscreen. |
| Display Type | LCD |
| Enclosure Ratings | IP20 |
| Frequency Input Range | 0 to 25 kHz |
| GrossWeightValue | 3.6 |
| Height | 6.65 in |
| Impedance Input | Current Input Impedance: 30Ω,Voltage Input Impedance: 1 GΩ,Frequency Input Impedance: 58 kΩ |
| Input Control Signal | Millivolt input: -100 to 2450 mV Volt input: -0.5 V to 12.0 V |
| Input Current | -5 to 50 mA |
| Input Type | Thermocouple, RTD, Thermistor, Current,Voltage, Digital |
| Length | 1.41 in |
| Materials | Polycarbonate |
| Memory | 1,000,000 or 5,000,000 Readings |
| Memory Note | 1,000,000 or 5,000,000 Readings |
| Mounting | Handheld, Tabletop or Wall Mounting |
| Number of Channels | 8 |
| Pulse Input Note | 0 to 4,000,000,000 Pulses |
| Relative Humidity | 0 to 95% RH non-condensing |
| Resolution | 0.1 °C |
| Resolution Note | Current Resolution: 0.0001 mA Voltage Resolution: 0.0001 mV, 0.0001 V RTD Resolution: 0.01 °C Thermisor Resolution: 0.01 °C Thermocouple Resolution: J, K, T, E, N: 0.1 °C R, S, B: 0.5 °C |
| Sampling Rate | 4 kHz |
| Series ID | OM-CP-OCTPRO-Logger |
| Start Modes | Delayed Start, Immediate Start |
| Supply Power Note | • Rechargeable 3.7 V Lithium Ion Battery, • Continuous on-screen sampling: 9 hours; Stand-by mode: 100 hours |
| Supply Power Type | USB |
| Temperature Measurement Range | J: -200 to 760 °C,K: -270 to 1370 °C,T: -270 to 400 °C,E: -270 to 980 °C,R: -50 to 1760 °C,S: -50 to 1760 °C,N: -270 to 1300 °C,B: 50 to 1820 °C,RTD: -200 to 850 °C,TH 2252Ω, 10KΩ: -25 to 150°C |
| Thermocouple Type | J, K, T, E, N, R, B, S |
| Weight | 1.3 lb |
| Width | 4.4 in |
| Wiring/Connector Table | 2-, 4-Wire RTD |
| Country of Origin | United States |
| See All Specs | |
PDFs & Manuals
Software & Drivers