Netherlands 07077 03815 | Intl +31 (0) 7077 03815 | Welcome to our new site - found a bug? Please report it here
LC8200
2 in OD Through-Hole, Compression Load Cells
- 5 Point NIST Traceable Calibration with
59 kOhm Shunt Cal Data - Low Profile
- All Stainless Steel Construction
- Rugged Industrial Design
Product Overview
- 5-Point Calibration 0%, 50%, 100%, 50%, 0%
- Calibration Option 5 POINT NIST
- Electrical Connection Cable
- Electrical Output 2 mV/V
- Force Type Compression
- Full Scale Deflection 0.003 in
- Input Resistance 360 Ω min
- Linearity ± 0.5%
- Load Cell Type Through Hole
- Materials 17-4 PH Stainless Steel
- Operating Temperature, Max 121 °C
- Operating Temperature, Min -54 °C
- Outer Diameter 2 in
- Output Resistance 350 ± 5 Ω
- Overload, Max 300% FS
- Process Temperature, Max 71 °C
- Process Temperature, Min 16 °C
- Repeatability ± 0.1%
- Safe Overload 150% FS
- Supply Power Note 10 Vdc, 15 Vdc maximum
- Supply Voltage 10 Vdc
- Thermal Span Effect ± 0.036% rdg/°C
- Thermal Zero Effect ± 0.009% FSO/°C
- Wiring/Connector Table Green: (+) Output; White: (-) Output; Black: (-) Input; Red: (+) Input
- Zero/Balance Error ± 2%
LC8200-Series load cell with 2 mV/V output, ±0.5% FSO linearity, and 17-4 PH stainless steel construction. Operates from -54 to 121°C. Includes 5' shielded cable. Handles up to 300% overload capacity.
PDFs & Manuals