Skip to search Skip to main content Skip to navigation

India +91 8925807296 | Welcome to our new website, found an issue or bug? Please report it here

We noticed you are in , please visit your local site by clicking the below link for regional offers and support.

Series-TE-OND-TE-RND-TE-OSA

Outdoor Temperature Sensors for Building Automation – Minimize Heat Impact

  • Weatherproof for outdoor installation
  • Radiation shield available to eliminate heating effects following installation in direct sunlight
  • Terminal connector eliminates need for wire nuts
Series-TE-OND-TE-RND-TE-OSA
From $ 85.01
Outdoor Temperature Sensors for Building Automation – Minimize Heat Impact Series-TE-OND-TE-RND-TE-OSA Series-TE-OND-TE-RND-TE-OSA
loading all models
Product Overview
  • Housing Material Polycarbonate
  • Operating Temperature, Max 302 °F
  • Operating Temperature, Min -40 °F
  • Series ID Series-TE-OND-TE-RND-TE-OSA
  • Weight 0.65 lb

Supported Applications

The Dwyer Series TE-OND, TE-RND, and TE-OSA Outdoor Temperature Sensors are designed to measure ambient air temperature for building automation systems. These sensors provide outdoor temperature reference data while offering protection against radiated heat effects from direct sunlight or surrounding structures.

Operating Conditions & Performance

The series operates within a temperature range of -40 to 302°F (-40 to 150°C). Accuracy specifications vary by sensor element type:

  • Thermistor sensors: ±0.22°C @ 25°C (±0.4°F @ 77°F)
  • RTD sensors: DIN class A: ±0.15°C @ 0°C (±0.28°F @ 32°F)

Housing materials consist of polycarbonate. Enclosure ratings differ by model family: TE-OND and TE-RND models carry a NEMA 4X (IP65) rating, while the TE-OSA model is rated NEMA 3R (IP54). For vertical plane mounting on TE-OSA units to meet NEMA 3 Ratings, a drain hole must be drilled as indicated in installation documentation.

Configuration Options

The series supports multiple sensor configurations and housing styles tailored for specific outdoor environments. A terminal connector is provided to eliminate the need for wire nuts during electrical connection.

Sensor Types by Model Suffix

  • -A: 10 kΩ type III thermistor
  • -B: 10 kΩ type II thermistor
  • -C: 3 kΩ thermistor
  • -D: PT100 Ω RTD
  • -E: PT1000 Ω RTD
  • -F: 20 kΩ thermistor
  • -Q: 10 kΩ type III thermistor with 11 kΩ shunt

Housing and Mounting Options

  • TE-OND / TE-RND: Designed for outdoor installation; radiation shield options are available to eliminate heating effects in direct sunlight.
  • TE-OSA: Features a quick 1/4 turn lid captured by a chain to prevent loss during installation. The internal terminal block provides reliable electrical connection without wiring nuts.

The TE-OND and TE-RND models are noted for use where the north side of a building is accessible to protect against low levels of radiated heat, while radiation shields address direct sunlight exposure.

Key Product Differences

Differences across the series primarily involve housing geometry and enclosure ratings. The TE-OND measures 4-17/32 in [115.09] x 3-1/8 in [79.38] x 5-1/8 in [130.18], while the TE-RND is larger at 8-43/64 in [220.27] x 4-31/32 in [126.21] x 5-1/8 in [130.05]. The TE-OSA housing dimensions are listed as 4-25/32 in [121.61] depth, with a lid diameter of 4-9/32 in [108.91] and overall height of 6-1/4 in [158.56].

Model numbering follows the pattern TE-<Series>-<Sensor Type>, where Series is OND, RND, or OSA, followed by a letter suffix indicating the specific sensor element (e.g., TE-OND-A, TE-RND-D, TE-OSA-Q).

en-IN
en_IN
Save Configuration