Skip to search Skip to main content Skip to navigation

Australia +61-2-4272 2055 | Welcome to our new website, found an issue or bug? Please report it here

We noticed you are in , please visit your local site by clicking the below link for regional offers and support.

LVP51

Non-Intrusive RF Capacitance Sensors Selectable NO or NC

  • Detects Liquid Through Plastic or Fiberglass Tank Walls Up to 1' Thickness
  • 1 AMP SPST Relay Output Standard
  • Sensor Conveniently Slides In and Out of Mounting Bracket In PE or PP
  • Ideal For Many Ultrapure and Sanitary Applications
LVP51
From $ 389.29
Non-Intrusive RF Capacitance Sensors Selectable NO or NC LVP51 LVP51
loading all models
Product Overview
  • Accuracy ± 0.04 inH2O
  • Approvals General purpose, CE
  • Cable Length 1000 ft
  • Dielectric Range 10 to 80 dielectric units @ 1 MHz
  • Enclosure Ratings IP65, NEMA Type 4
  • Indicator Type LED: Calibration and liquid status feedback
  • Loop Resistance 600 Ω @ 24 Vdc
  • Materials Plastic, Fiberglass
  • Materials, Wetted Polypropylene
  • Media Compatibility Clean process / cooling water, Oils / lubricants, Organic solvents
  • Operating Temperature, Min -40 °C
  • Power Consumption 25 mA
  • Repeatability ± 0.04 inH2O
  • Series ID LVP51
  • Supply Power Type DC
  • Supply Voltage 12 to 30 Vdc
  • Switch Operation Selectable Normally Open or Normally Closed
  • Switch Rating 1 A @ 60 or 120 Vac/Vdc
  • Switch Type SPST
  • Tank Wall Thickness 1 in
  • Wire Gauge 22 AWG

Supported Applications

The Omega LVP-51 series consists of non-intrusive RF capacitance level switches designed for liquid detection through plastic or fiberglass tank walls. These sensors generate a high radio frequency signal from an electrode on the exterior to detect changes in dielectric value, determining liquid presence without penetrating the vessel wall. The series is intended for liquids with a dielectric constant between 20 and 80 (with some sources noting capability down to 10 units) and conductivity greater than 100 μS/cm.

Documented applications include:

  • Liquid level detection in non-metallic tanks
  • Ultrapure and sanitary applications using weld-on fittings for polyethylene, fiberglass, or polypropylene vessels

Operating Conditions & Performance

The LVP-51 series operates within a temperature range of -40° to 80°C (-40° to 176°F). The sensor is rated for tank wall thicknesses up to 25.4 mm (1") and requires non-metallic mounting surfaces; installation on metallic tanks or within 6" of any metallic object is prohibited.

Performance specifications include:

  • Accuracy: ±1 mm (0.04") in water
  • Repeatability: ±0.5 mm (0.02") in water
  • Dielectric Range: 10 to 80 dielectric units @ 1 MHz (or > 20 constants per manual)
  • Power Supply: 12-36 VDC with maximum consumption of 25 mA

The enclosure is constructed from Polysulfone and carries a NEMA 4X (IP65) or NEMA 4 (IP65) rating, described as splash-proof and chemical resistant. The sensor is not designed for immersion.

Configuration Options

The series offers configurable mounting options and output signals to accommodate specific installation requirements:

  • Mounting Brackets/Fittings: Available in Polyethylene (PE) as model LVP-91 or Polypropylene (PP) as model LVP-92. Fittings utilize 3M adhesive for temporary holding during welding, glazing, or strapping.
  • Cable Options: Standard length is 3 m (10') with a shielded 4-conductor #22 AWG cable. Extended lengths are available: add suffix '-25' for 7.62 m (25') or '-50' for 15.24 m (50'). Maximum supported length is noted as 305 m (1000').
  • Output Signals:
    • Selectable NO/NC SPST mechanical relay output (60 VA, 1A maximum; CE rated at 60 Vac/Vdc @ 1 A)
    • FET switch and 4-20 mA sensor outputs
    • Single LED for calibration and liquid status feedback
  • Electrical Connection: Single, 1/2" NPT conduit entrance.

Key Product Differences

The primary model LVP-51-R is the non-intrusive capacitance sensor with a Polysulfone housing. Distinctions in the series are defined by mounting hardware and cable configuration:

  • LVP-91 vs. LVP-92 Fittings: The LVP-91 fitting is made of PE, while the LVP-92 fitting is PP; both measure 6.4 x 6.4 cm (2.5" x 2.5").
  • Cable Length Variants: Standard units include a 3 m cable; variants with suffixes '-25' or '-50' provide extended lengths for additional cost.

Accessories

installation hardware

PP FITTING
AUD82.24 / each
0 In Stock

sensors

PE FITTING
$48.31 / each
0 In Stock
en-AU
en_IN
Save Configuration