India +91 8925807296 | Welcome to our new website, found an issue or bug? Please report it here
FP5060-Series
Micro-Flow Polypropylene Sensors For Low Flow Applications
- Measures Flow Rates As Low As 0.03 GPM, 0.11 LPM
- Splash-Proof
- All Plastic Construction for Superior Chemical and Corrosion Resistance
Product Overview
- Cable Length 25 m
- Display Type None
- Electrical Output 10_mA
- Height 1.42 in
- Length 3.96 in
- Linearity Error ±1%
- Materials, Wetted FKM, PEEK, Polyphenylene Sulfide
- Media Compatibility Liquids
- Mounting Horizontal Surface ±30°
- Operating Pressure, Max 80 psi
- Operating Temperature, Max 80 °C
- Operating Temperature, Min 0 °C
- Output Detail Open collector NPN transistor, 10 mA maximum sink
- Pressure Drop, Max 25 psi
- Repeatability Error 0.005
- Series ID FP5060-Series
- Viscosity Range 0 to 20 cPs
- Volumetric Flow Rate, Max 2.6 l/min
- Volumetric Flow Rate, Min 0.11 l/min
- Weight 9.6 kg
- Width 3.2 in
Supported Applications
The Omega FP-5060 Series Micro-Flow Sensors are designed for measuring low flow rates in clean fluids. These sensors generate pulses proportional to flow volume and are suitable for applications requiring precise flow monitoring of clean process liquids, regardless of fluid color.
Operating Conditions & Performance
The series operates within a process temperature range of 0 to 80 °C (32 to 176 °F) with a maximum pressure rating of 5.5 bar (80 psi). Accuracy is specified as ±1% of full range, and repeatability is 0.5% of full range.
Measurement ranges vary by model:
- FP-5061 and FP-5062: 0.11 to 2.6 lpm (0.03 to 0.7 gpm)
- FP-5063: 1.13 to 12.11 lpm (0.3 to 3.2 gpm)
The sensors are suitable for clean fluids only; suspended solids will cause mechanical failure.
Configuration Options
The FP-5060 Series offers configurable process connections and flow ranges across three primary models:
- Process Connections: ¼ in. NPT (male) or ISO 7/1 - R¼ (male)
- Housing Material: Polyphenylene sulfide
- Wetted Materials:
- Sensor body and cover: 40% glass filled Polyphenylene Sulfide
- Rotor: PEEK, natural, unfilled
- O-rings (Rotor and Cover): Viton® / FKM
- Output Signal: Open-collector NPN transistor, 10 mA max sink
- Power Supply: 5 to 24 VDC, regulated @ 10 mA maximum
- Cable Length: 7.5 m (25')
- Electrical Connection: 2-conductor twisted pair w/shield (Belden 8451)
The series supports horizontal surface mount installation within ±30° for optimum performance; vertical mounting is not recommended. Accessories include the DPF701 rate or total panel meter.
Key Product Differences
Differences between models are defined by port type and flow range:
- FP-5061: ¼ NPT connection; Flow Range: 0.11 to 2.6 LPM (0.03 to 0.7 GPM)
- FP-5062: ISO 7/1-R¼ connection; Flow Range: 0.11 to 2.6 LPM (0.03 to 0.7 GPM)
- FP-5063: ¼ NPT connection; Flow Range: 1.13 to 12.11 LPM (0.3 to 3.2 GPM)
Pulse output rates differ by model, with FP-5061 and FP-5062 generating 9950 pulses per U.S. gallon (2629 pulses per liter), while the higher-flow FP-5063 generates 3160 pulses per U.S. gallon (834.9 pulses per liter).
PDFs & Manuals