Skip to search Skip to main content Skip to navigation

India +91 8925807296 | Welcome to our new website, found an issue or bug? Please report it here

We noticed you are in , please visit your local site by clicking the below link for regional offers and support.

OPTIDEW

Michell Optidew Chilled Mirror Hygrometer

  • New chilled mirror hybrid sensor gives fast dynamic response to changes in humidity
  • Accurate to ±0.15°C dew point, ±0.1°C temperature
  • Wide measurement range from -40 to +120°C dew point
  • Choice of communication methods, including Modbus TCP over Ethernet communication for easy networking
OPTIDEW
From
Michell Optidew Chilled Mirror Hygrometer OPTIDEW OPTIDEW
loading all models
Product Overview
  • Accuracy ± 0.15 °C (± 0.27 °F)
  • Accuracy Detail Dew Point Measurement Accuracy: ±0.15°C (±0.27°F); Temperature Measurement Accuracy: ±0.1°C (±0.18°F); Remote Pressure Accuracy: ±0.25% FS
  • Body Material Aluminum
  • Cable Temperature, Max 90 °C
  • Cable Temperature, Min -25 °C
  • Control Output Relay, Alarm
  • Dew Point Temperature Input Range -25 to 90°C
  • Display Size 5.7 in
  • Display Type Color LCD Touchscreen
  • Electrical Output 4 to 20 mA
  • Enclosure Material ABS
  • Enclosure Ratings IP54
  • Length 220 mm
  • Load Resistance maximum load 500Ω
  • Mounting Orientation Benchtop
  • Power Consumption 30 VA max
  • Selectable Pressure Range 0 to 160 kPa, 0 to 2500 kPa
  • Process Connection Size 1/8 in
  • Process Connection Type NPT Male
  • Protection Active Component Isolation System
  • Repeatability ±0.05°C (±0.09°F)
  • Response Time Stable measurement at +10°C (+50°F) dp within 1 minute
  • RTD Type Pt1000, Class A
  • Sensitivity ±0.01°C (±0.018°F)
  • Series ID OPTIDEW
  • Supply Voltage 100 to 240 Vac
  • Weight 1.5 kg
  • Weight Note Control unit: 1.5 kg (3.3 lb), Sensor: 200 g (7.05 oz)
  • Width 175 mm

Supported Applications

The Michell Optidew series comprises chilled mirror hygrometers designed for industrial humidity control and precision laboratory applications. The system combines the fast response of polymer relative humidity sensors with drift-free reliability, measuring dew point, temperature, and relative humidity.

  • Bench top configurations (Optidew 401) feature a display unit suitable for stationary monitoring.
  • Wall mount configurations (Optidew 501) are available as units with displays or transmitter-only versions.

Operating Conditions & Performance

The series provides dew point measurement ranges of -40 to +90°C (-40 to +194°F), -25 to +90°C (-13 to +194°F), and an extended range of -40 to +120°C (-40 to +248°F) depending on the selected sensor head. Accuracy is specified as ±0.15°C (±0.27°F) for dew point and ±0.1°C (±0.18°F) for temperature, with a repeatability of ±0.05°C (±0.09°F). The system achieves stable measurement at +10°C (+50°F) dp within 1 minute.

Operating ambient conditions are -20 to +50°C (-4 to +122°F), supporting up to 100% rh non-condensing, or 100% rh condensing with the IP65 connector version. The sensor head materials include POM (head) and Aluminum (body) for standard configurations, while harsh environment options utilize PEEK (head). Wetted parts are highly resistant to corrosion from acids and other gas contaminants.

Configuration Options

Sensor Heads & Ranges

  • POM Head, 1-Stage: -25 to 90°Cdp
  • POM Head, 2-Stage: -40 to 90°Cdp
  • Harsh Environment (PEEK) Head, 2-Stage: -40 to 120°Cdp

Housing & Mounting Options

The Optidew 501 series offers wall mount cases with display or transmitter-only configurations. Enclosure ratings include IP54 standard and optional IP65 (restricted to RS485 communications only for certain models). Dimensions are 220 x 175 x 118 mm (8.66" x 6.89" x 4.65") for bench top units and 220 x 175 x 75 mm (8.66" x 6.89" x 3") for wall mount cases.

Outputs & Communications

  • Analog: Two 0/4–20 mA outputs with a maximum load of 500Ω.
  • Digital Standard: Modbus RTU over RS485 and USB port.
  • Digital Optional: SD card slot, Modbus TCP over Ethernet (available on select models).

Calibration & Accessories

Factory calibration options include Standard Traceable DP Cal (4 points) or UKAS / ISO17025 certified calibrations for Dew Point (5 points) and Relative Humidity (5Ps @ one temperature). The series supports optional pressure transmitters (OPT2-PS16: 0 to 160kPa(A); OPT2-PS25: 0 to 2500kPa(G)) for accurate calculation of ppmᵥ & g/kg. Additional accessories include sensor sampling blocks, extended heatsinks, sintered aluminum guards with PTFE coating, and various cable lengths (0.3m to 20m) rated for standard or high-temperature applications.

Key Product Differences

The series is divided into two primary model families: the Optidew 401 Bench Top Hygrometer with display and the Optidew 501 Wall Mount Hygrometer. The Optidew 501 offers distinct case configurations including wall mount units with displays, IP65-rated versions restricted to RS485 communications only, and transmitter-only housings without local displays.

Communication capabilities vary by model selection; while USB and SD card interfaces are standard on many variants, the optional Ethernet interface is available for specific configurations. High-temperature sensor cables (OPT2-HTSC series) support measurements up to 120°C with probe leads rated to 250°C at the connector.

OPT401OPT501-ABCDABCABCABCDEFGHJABABCD
Base Model
Case
Sensor
Calibration
Cables for Dew Point and Temperature
Digital Communications (Optidew 401)
Digital Communications (Optidew 501)
Order codes: https://assets.dwyeromega.com/0/order-codes/791_Optidew401_501_97552_Order_Codes.pdf
en-IN
en_IN
Save Configuration