Skip to search Skip to main content Skip to navigation

India +91 8925807296 | Welcome to our new website, found an issue or bug? Please report it here

We noticed you are in , please visit your local site by clicking the below link for regional offers and support.

iLD-DP

Large Display Meters & PID Controllers

  • BIG, bright LED digits in 2.25" or 4" sizes for easy viewing at a distance
  • Programmable color display (red, amber, green) for instant status indication
  • Wide input options with optional alarms, PID control, and relay outputs
  • Ethernet and serial communications with embedded web server support
While this item has an extended lead time, our LDB series offer similar specs and shorter wait times.
iLD-DP
From $ 1,500.52
Large Display Meters & PID Controllers iLD-DP iLD-DP
loading all models
Product Overview
  • A/D Conversion Dual slope
  • Common Mode Rejection 120 dB
  • Current Measurement Range 0 to 20 mA
  • Decimal Selection 0, 0,001, 0,01, 0,1
  • Digital Filter Programmable
  • Display Type 4 Digit Single LED
  • Display Type Note 4-digit, 7-segment LED 57.2 mm (2.25") or 101.6 mm (4.00") red, green and amber programmable colors for process variable, set point and temperature units
  • Enclosure Ratings NEMA Type 1
  • Excitation Voltage Note Optional in Place of Communication
  • Impedance Input 10 MΩ for 100 mV, 1 MΩ for 1 or 10 Vdc
  • Input Configuration Single-ended
  • Normal Mode Rejection 60 dB
  • Number of Inputs 1
  • Offset Adjustment -1999 to +9999
  • Operating Temperature, Max 40 °C
  • Operating Temperature, Min 0 °C
  • Polarity Unipolar
  • Power Consumption 22.5 W
  • Reading Rate 3 samples/sec
  • Relative Humidity 90% RH non-condensing
  • Sampling Rate 3 Hz (3 updates/second)
  • Series ID iLD-DP
  • Set Point Adjustment -1999 to 9999 counts
  • Span Adjustment 0.001 to 9999 counts, programmable
  • Step Response 0.7 sec for 99.9%
  • Supply Power Note 100 to 240 Vac ±10%, 50/60 Hz 22.5 W
  • Supply Power Type AC
  • Supply Voltage 100 to 240 Vac
  • Temperature Stability RTD: 0.04°C/°C ;Thermocouple @ 25°C (77°F): 0.05°C/°C, cold junction compensation ;Process: 50 ppm/°C ;
  • Thermocouple Lead Resistance, Max 100 Ω
  • Voltage Measurement Range 0 to 100 mV, 0 to 1 V, 0 to 10 Vdc
  • Warm-Up to Rated Accuracy 60 min

Supported Applications

The Omega iLD Series comprises large-display digital panel meters and controllers designed for universal temperature monitoring, process measurement, strain gage applications, AC current/voltage sensing, frequency/pulse/rate totalization, and remote display via serial or Ethernet inputs. The series supports thermocouple types J, K, T, E, R, S, B, C, N, L (ITS 90) and RTD sensors (100/500/1000 Ω Pt, ITS 68). Configurable models serve as monitors or controllers with optional full PID control for heating or cooling processes.

Operating Conditions & Performance

The iLD Series operates in ambient temperatures from 0 to 40°C (32 to 104°F) at up to 90% RH non-condensing. A warm-up period of 60 minutes is required for UTP, SP, FP, ACC, and ACV models to achieve rated accuracy. Accuracy specifications vary by input model: Universal Temperature/Process (UTP) offers ±0.5°C temperature stability or 0.03% reading process; Strain/Process (SP) provides 0.03% reading accuracy; Frequency/Pulse (FP) achieves ±0.1% of FS with crystal time-based accuracy of ±50 ppm; AC Current (ACC) and AC Voltage (ACV) models specify ±0.2% of FS at 25°C within their respective frequency ranges.

Response times are documented as a step response of 0.7 sec for 99.9% final value on UTP and SP inputs, while ACC and ACV models respond in 2 s to 99% (filter time constant = 64). FP models with RS485 output achieve 0.1 s to 99%. The display updates at a reading rate of 3 samples per second.

Configuration Options

The series is available in two digit sizes: 57 mm (2.25") or 101 mm (4"), with either 4-digit or 6-digit displays depending on the model code. The enclosure provides NEMA 4 (IP65) protection for the entire unit, including a front bezel rated NEMA 4 (IP65). Mounting options include flush panel installation using specified cutouts or surface mounting via included brackets.

Input configurations cover:

  • UTP: Universal temperature and process inputs supporting thermocouples, RTDs, voltage (0 to 100 mV, 0 to 1 V, 0 to 10 Vdc), and current (0 to 20 mA).
  • SP: Strain gage and process inputs with analog voltage (-100 mVdc to 1 Vdc) and current capabilities.
  • ACC/ACV: Dedicated AC current ranges (10 mA, 100 mA, 1 A, 5 A) and AC voltage ranges (400 mV, 4 V, 40 V, 400 V).
  • FP: Frequency/pulse inputs from 0.2 Hz to 50 KHz with totalize modes including reset, A-B totalize, and quadrature.

Communication options include isolated RS232/RS485/422 (standard on FP, ACC, ACV; optional via -C24 or -EI suffixes) and Ethernet with embedded web server (-C4EI). The series supports IEEE 802.3, 10 Base-T standards for network models.

Key Product Differences

The iLD Series differentiates primarily by input type (UTP, SP, FP, ACC, ACV) and display configuration (digit size and count). Control outputs are available only on UTP and SP models via the -33 option, providing 2 relays form C SPDT rated at 3 A @ 120/240 Vac. Factory scaling (-FS) is offered for specific input ranges such as converting a 4-20 mA signal to a scaled display value.

Model codes indicate digit size and count: "iLD2" denotes the 57 mm (2.25") display, while "iLD4" indicates the 101 mm (4") display; the following number specifies digits (e.g., iLD24 is a 4-digit unit). Remote display models (-C2 and -EI) accept serial or Ethernet inputs to drive the large LED panel without local sensor connections.