Discontinued, no replacement

  • Metal-Oxide Semi-Conductor Sensor within Vented Ball Housing Detects Ammonia, Toluene, Ethanol, Hydrogen Sulfide (H2S) and Cigarette Smoke
  • Make Total VOC Concentration Measurements, Ambient Temperature, Relative Humidity (RH), Dew Point and Wet Bulb Temperatures
  • Logs Up to 32,000 Data Points
  • Powerful Data Logging Software
  • Adjustable High VOC Concentration Audible Alarm
  • Min/Max Memory (for All Measured Parameters) and Data Hold
  • Separate Automated Procedures for VOC Zero Adjustment and Background Calibration
  • Manually Off-Settable Temperature and RH Sensor Drift
  • Large Backlit Dual-Readout LCD
  • Tripod Mountable
HHAQ-107-Meter
From $ 798.35
Handheld Volatile Organic Compound (VOC) Meter HHAQ-107-Meter HHAQ-107-Meter
loading all models
Product Overview
  • Additional Features 1 Sensor Longevity for Metal-oxide semiconductor - 5 years (typical)
  • Air Quality Measurement 0 to 50 ppm
  • Auto Power Off 15 minutes of front-panel inactivity (can be disabled)
  • Battery Size and Type Alkaline AAA
  • Data Logging 32,004 points
  • Dew Point Temperature, Max 47 °C
  • Dew Point Temperature, Min -73 °C
  • Display Size 51 mm (2 in)
  • Display Type Dual Readout LCD
  • Height 25 mm
  • Length 210 mm
  • Number of Batteries 6
  • Operating Humidity 0 to 95% RH
  • Operating Temperature, Max 50 °C
  • Operating Temperature, Min 0 °C
  • Process Temperature, Max 50 °C
  • Process Temperature, Min -10 °C
  • Relative Humidity 10 to 90%
  • Relative Humidity Accuracy ± 5% RH
  • Relative Humidity Accuracy Note ±5% of reading at 25°C ; ±7% of reading elsewhere in range
  • Relative Humidity Resolution 0.1% RH
  • Resolution 0.01 ppm
  • Sensor Type Metal-Oxide Semiconductor, RH Sensor Drift
  • Series ID HHAQ-107-Meter
  • Supply Power Note (6) “AAA” batteries (included) or included 110 Vac adaptor
  • Temperature Accuracy ± 0.6 °C
  • Temperature Resolution 0.1 °C
  • Warm Up Time 10 minutes first use, 2 minutes thereafter
  • Weight 204 g
  • Wet Bulb Temperature, Max 48.2 °C
  • Wet Bulb Temperature, Min -11 °C
  • Width 60 mm

Supported Applications

The Omega HHAQ-107 is a handheld instrument designed for making ballpark measurements of mixed-gas volatile organic compound (VOC) levels as part of an indoor air quality (IAQ) maintenance program. It utilizes a metal-oxide semiconductor sensor within a vented ball housing to detect ammonia, toluene, ethanol, hydrogen sulfide (H2S), and cigarette smoke.

The device is intended for spot-checking concentrations of mixed-gas VOCs rather than precise single-gas measurements. In addition to total VOC concentration, the meter measures ambient temperature, relative humidity (RH), dew point, and wet bulb temperatures.

Operating Conditions & Performance

The HHAQ-107 operates within an ambient temperature range of 0 to 50°C (32 to 122°F) at 0 to 95% RH, non-condensing. The instrument features a large backlit dual-readout LCD with a 51 mm (2") diagonal display.

Performance specifications for the series include:

  • VOC Measurement Range/Resolution: 0 to 50 ppm / 0.01 ppm
  • VOC Warmup Time: 10 minutes first use, 2 minutes thereafter
  • Temperature Measurement Accuracy/Resolution: ±0.6°C (1.2°F) / 0.1°
  • RH Measurement Range: 10 to 90% RH
  • RH Measurement Accuracy/Resolution: ±5% of reading at 25°C (77°F); ±7% of reading elsewhere in range / 0.1% RH
  • Dew Point Measurement Range: -73 to 47°C (-99.2 to 118°F)
  • Wet Bulb Measurement Range: -11 to 48.2°C (12.2 to 118.8°F)

The device includes an adjustable high VOC concentration audible alarm, min/max memory for all measured parameters, and a data hold function.

Data Logging & Power

  • Capacity: Logs up to 32,004 points. The entire capacity can be devoted to VOC readings or divided one-third each among VOC, ambient temperature, and RH readings.
  • Interface: USB cable included for connection to a PC-compatible data logging program on mini-disc.
  • Power Source: (6) 'AAA' batteries (included) or included 110 Vac adaptor.
  • Auto Power-Off Trigger: 15 minutes of front-panel inactivity (can be disabled).

Configuration Options

The HHAQ-107 series is offered as a single handheld configuration with the following documented capabilities and included accessories:

  • Housing Material: Black and yellow plastic housing.
  • Sensor Type/Longevity: Metal-oxide semiconductor / 5 years (typical).
  • Data Logging Modes: Software supports four data logging modes, including starting and stopping recording without a PC.
  • Calibration Features: Automated VOC zero adjustment procedure; manually offsettable temperature and RH sensor drift.
  • Mechanical Mounting: Tripod mountable design.

The package includes the HHAQ-107 instrument, PC-compatible data logging program on mini-disc, USB cable, AC adaptor, soft pouch, (6) 'AAA' batteries, and operator's manual. Replacement parts include MN2400 replacement 'AAA' batteries (2 per pack, 3 packs needed).

Key Product Differences

The HHAQ-107 is the sole model in this series bundle. The device features a dual-readout LCD display and includes an automated VOC zero adjustment procedure to maintain sensor baseline.

en-IN