OM-CP-EVENT101A-Logger

Event Data Logger

  • Interfacce per pluviometri a secchiello basculante e
  • altri dispositivi con uscita a impulso TTL o contatto di chiusura
  • Durata batteria 10 anni
  • Frequenza di lettura 4 Hz
OM-CP-EVENT101A-Logger
From $ 156.93
Event Data Logger OM-CP-EVENT101A-Logger OM-CP-EVENT101A-Logger
loading all models
Product Overview
  • Accuracy ± 1 min/month
  • Accuracy Detail ±1 minute/month at 20°C, stand alone data logging
  • Battery life up to 10 yr
  • Battery Size and Type 3.6V Li-ion
  • Velocità di trasmissione 115200
  • Interfaccia dati USB
  • Collegamento elettrico Removable Screw Terminal
  • Altezza 1.4 in
  • Impedenza in ingresso >60 kΩ
  • Pull-up interno debole <60 μA
  • Indicatori LED Green LED Blinks:10 second rate to indicate logging; 15 second rate to indicate delay start mode;Red LED Blinks:10 second rate to indicate low battery and/or full memory
  • Lunghezza 0.6 in
  • Materiali ABS, Aluminum
  • Memoria 406,323 readings; software configurable memory wrap
  • Modalità multipla avvio/arresto Nota To Start the Device:Press and hold the pushbutton for 5 seconds, the green LED will flash during this time. The device has started logging To Stop the Device:Press and hold the pushbutton for 5 seconds, the red LED will flash for 3 seconds and then the green LED will flash for two seconds. The device has stopped logging
  • Numero di misurazioni 1
  • Temperatura di esercizio, max 80 °C
  • Temperatura di esercizio minima -40 °C
  • Protezione An optional password may be programmed into the device to restrict access to configuration options. Data may be read out without the password.
  • Registrazione in tempo reale The device may be used with PC to monitor and record data in real-time
  • Umidità relativa 0 to 95% RH non-condensing
  • Risoluzione 4 Hz
  • Tempo di risposta, min 10 µsec
  • Campioni, max 0.25 sec
  • Frequenza di campionamento 4 Hz (4 updates/second)
  • ID serie OM-CP-EVENT101A-Logger
  • Software XP SP3/Vista/7 and 8 (32 and 64-bit)
  • Tipo di alimentazione Battery
  • Range di ingresso della tensione 0 to 30 vdc
  • Peso 0.9 oz
  • Larghezza 2.2 in

Supported Applications

The Omega OM-CP-EVENT101A is an event data logger designed for recording input transitions or contact closures from external sources. Documented applications include monitoring pulse state initiators such as gas, water, and electric meters.

Operating Conditions & Performance

The device operates in ambient temperatures of -40 to 80°C (-40 to 176°F) with a humidity rating of 0 to 95% RH non-condensing. It features an input range of 0 to +30V, distinguishing between Input Low (<0.4V) and Input High (>2.8V). The logger records events with a minimum active (low) time detection of 10 Microseconds and offers a reading rate selectable from 4 Hz down to once every 24 hours.

Time accuracy is specified as ±1 minute/month at 20°C (68°F) for stand-alone data logging. The unit stores up to 406,323 readings in non-volatile solid-state memory with configurable wrap-around capability. Power is supplied by a user-replaceable 3.6V lithium battery included with the device, providing a typical life of 10 years dependent upon frequency and duty cycle.

Configuration Options

The series supports various configuration options for connectivity, power maintenance, and environmental protection:

  • Data Retrieval & Software: USB interface (cable required) at 115,200 baud; compatible with Windows XP SP3/Vista/7 and 8 (32 and 64-bit). The OM-CP-IFC200 accessory includes the software and a 1.8 m (6') USB cable.
  • Enclosures: Standard ABS Plastic housing; optional NEMA 4 (IP65) weatherproof enclosure (OM-CP-WATERBOX101A) constructed of black anodized aluminum with dimensions of 74 H x 148 W x 39 mm D (2.9 x 5.8 x 1.5").
  • Power & Maintenance: Replacement battery OM-CP-BAT105; maintenance kit OM-CP-WATERBOX101A-KIT for the waterbox enclosure.
  • Configuration Features: Immediate start, delay start up to 18 months, and multiple pushbutton start/stop modes. Optional password protection restricts access to configuration options while allowing data readout without a password.

Key Product Differences

The OM-CP-EVENT101A is the base event data logger model within this series. The product family includes specific accessory models for interface connectivity (OM-CP-IFC200), battery replacement (OM-CP-BAT105), and environmental housing (OM-CP-WATERBOX101A). Engineering units can be scaled in software to display native measurement units or alternative types such as on/off, open/closed, or rainfall. The device includes LED indicators for logging status, delay start mode, low battery conditions, and full memory states.