- On/off, PID, fuzzy logic, or manual output control
- Constant, sloped, program (ramp/soak), or remote set-point control
- 2 primary control outputs, 2 secondary/alarm relay outputs, and RS-485 standard on all models
- Remote set-point, input retransmission, or event input functions available with optional hardware
Series-16G-8G-4G
From
$
211.58
Product Overview
- Accuracy ± 1.8°F + ± 0.3% of span
- Accuracy Detail ± 1.8°F plus ± 0.3% of span (± 1°C plus ± 0.3% of span) at 77°F (25°C) after 20 minutes warm up
- Control Output SPST Relay
- Data Interface RS-485 Modbus ASCII/RTU
- Display Note Process value: 4 digit, 0.47˝ H (12 mm), orange LCD; Set point value: 4 digit, 0.47˝ H (12 mm), green LCD
- Display Type LCD
- Enclosure Ratings IP66
- Input Control Signal 0 to 20 mA
- Input Type Thermocouple, RTD, DC Voltage or DC Current
- Memory Backup Non-Volatile
- Number of Digits 4
- Operating Temperature, Max 122 °F
- Operating Temperature, Min 32 °F
- Output Type (B) Relay
- Power Consumption max 5 VA
- RTD Input Range JPt 100: -4 to 752°F; Pt 100: -328 to 1562°F; Ni 120: -112 to 572 °F; Cu 50: -58 to 302 °F
- Series ID Series-16G-8G-4G
- Storage Temperature, Max 150 °F
- Storage Temperature, Min -42 °F
- Supply Power Note 100 to 240 VAC -20/+8%, 50/60 Hz; Optional 24 VDC, ± 10%
- Supply Power Type AC
- Supply Voltage 100 to 240 Vac
- Switch Rating 5 A @ 250 Vac
- Switch Type SPST
- Temperature Sensor Type RTD or Thermocouple
- Thermocouple Input Range Note Type K: -328 to 2372°F; Type J: -148 to 2192°F; Type T: -328 to 752°F; Type E: 32 to 1112°F; Type W: -328 to 2372°F; Type R: 32 to 3092°F; Type S: 32 to 3092°F; Type B: 212 to 3272°F; Type L: -328 to 1562°F; Type U: -328 to 932°F, Type TXK: -328 to 1472 °F
- Voltage Input Range 0 to 5 V, 0 to 10 V
- Weight 9 oz
Supported Applications
The Dwyer Series 16G, 8G, and 4G are dual-loop temperature and process controllers designed for monitoring and control of temperature or general process conditions. These open-type units feature an RS-485 interface with Modbus® ASCII/RTU communication protocol to facilitate bench-top configuration or integration with a PLC or data control system.
Operating Conditions & Performance
The series supports multiple input types including Thermocouple (K, J, T, E, N, R, S, B, L, U, TXK), 3-wire Platinum RTD (Pt100, JPt100), Resistance sensors (Cu50, Ni120), and Analog inputs (0 ~ 5Vdc, 0 ~ 10Vdc, 4 ~ 20mA, 0 ~ 20mA, 0 ~ 50mVdc). Display accuracy is specified as ±1.8°F plus ±0.3% of span (±1°C plus ±0.3% of span) at 77°F (25°C) after a 20-minute warm-up period.
Performance characteristics include a sampling rate of 0.1 sec/per scan for both analog inputs and thermocouple or platinum RTD sensors. The controllers operate within an ambient temperature range of 32 to 122°F (0 to 50°C) with relative humidity between 35% ~ 80% RH (non-condensing). Storage conditions are rated from -42 to 150°F (-20 to 65°C). The front panel carries an IP66 rating, and the units comply with CE and cULus certifications.
Configuration Options
The series is available in three DIN sizes: 1/16 DIN (W48 × H48mm), 1/8 DIN (W48 × H96mm), and 1/4 DIN (W96 × H96mm). Each unit features two independent control outputs configurable for dual-loop operation. Control modes include PID, PID program control (Ramp/Soak), FUZZY, Self-tuning, Manual, and On/OFF.
Output signal options per channel include:
- Relay Output: SPST, 5 A @ 250 VAC resistive
- Voltage Pulse Output: 12Vdc (max. 40 mA)
- DC Current Output: 4 ~ 20mA (Load resistance Max. 500Ω)
- Linear Voltage Output: 0 ~ 10Vdc
The display consists of a dual-color LCD showing the Process Value in orange and Set Point in green, with selectable resolution of 0 or 1 digit to the right of the decimal point. Power supply options include 80 ~ 260Vac 50/60Hz; 24Vac 50/60Hz ±10%; or 24 Vdc ±10%.
Optional functions available via model configuration codes include Event Input, Retransmission Output, and CT (Current Transformer) input. Electrical connections utilize solder-less terminals with M3 screws (width 5.8 mm).
Key Product Differences
Variants within the Series-16G-8G-4G are distinguished by panel size, output group selections for Output 1 and Output 2, optional function assignments, and power supply type.
- DIN Size: Models begin with '16' (1/16 DIN), '8' (1/8 DIN), or '4' (1/4 DIN).
- Output Selections: Output groups are coded as 2 for Voltage Pulse, 3 for Relay, 5 for DC Current, and 6 for Linear Voltage.
- Function Options: Function codes include '0' (None), '1' or '4' depending on position for Event Input/CT input, and '3' for Retransmission Output. Remote setpoint is available as a function option in specific configurations.
PDFs & Manuals
Accessories
accessories
Weatherproof enclosure, type 4X, control direct panel mounts in the front of the enclosure.
$227.17 / each
0 In Stock
Weatherproof enclosure, type 4X, clear plastic window with rear panel for mounting the control inside the enclosure.
$484.97 / each
0 In Stock
sensors
J type, 100’ on spool, FEP insulation, 200°C, black outer sheath, 24 AWG, 0.20 SQMM
$49.91 / each
0 In Stock
K type, 100' on spool, FEP insulation, 200°C, yellow outer sheath, 24 AWG, 0.20 SQMM
$94.21 / each