India +91 8925807296 | Welcome to our new website, found an issue or bug? Please report it here
Series-DMF
Digital Mass Flow Controller for 10 Gases – Auto Zero & Tune Functions
- Straight-tube mass flow controller with auto-zero and auto-tune for high-precision gas application
- Accuracy ±1% FS, repeatability ±0.15%, covers multiple gases with programmable conversion
- Outputs include 0-5 V or 0-10 V; communication via RS-485 for totalizer, alarm, and control integration
- Rated to 500 psig, ultra-low leak integrity (<1 × 10⁻⁹ cc He/s); designed for clean, non-corrosive gases
Series-DMF
From
$
4,378.29
Product Overview
- Accuracy Detail ± 1% FS including linearity between 59 to 77°F (15 to 25°C) and 10 to 60 psia (0.7 to 4 bar); ± 2% FS from 32 to 122°F (0 to 50°C) and 5 to 150 psia (0.3 to 10 bar)
- Data Interface RS485
- Leak Rate Under Vacuum less than 10^⁻9 cc He/s
- Media Compatibility Clean dry air / inert gas, Fuel gases, HVAC / room air, Inert / non-reactive gases, Hydrogen, Nitrogen, Non-Corrosive Dry Gases, Oxygen
- Operating Temperature, Max 122 °F
- Operating Temperature, Min 41 °F
- Output Detail Linear 0-5 VDC (2000 Ω min. load impedance); 0-10 VDC (4000 Ω min. load impedance)
- Output Signal Voltage
- Particulate Size, Max 100 microns
- Measurement Pressure Type Gauge
- Process Connection Type Compression Fitting
- Repeatability ± 0.15%
- Response Time 0.6 to 1 s
- Response Time Note 0.6 to 1.0 second to within ± 2% of setpoint over 20% to 100% FS
- Series ID Series-DMF
- Supply Power Type DC
- Supply Voltage ± 15 Vdc
- Volumetric Flow Rate, Min 0 SCCM
Supported Applications
The Dwyer Series DMF Digital Mass Flow Controllers are designed for the precise control of gas flow in industrial applications. The series utilizes straight tube sensors with restrictor flow elements to ensure laminar gas flow, providing accurate and repeatable results unaffected by temperature and pressure variations. Calibration information is stored in memory for up to 10 gases, with conversion factors available for up to 256 different gases.
Supported media includes clean gases compatible with wetted parts (316 SS, 416 SS, fluoroelastomer O-rings). The series supports the following specific applications and functions:
- Precise control of gas flow rates
- Totalizer operations including stop totalizer and preset totalize from flow
- Auto zero balancing to eliminate drift of zero and span
- Operation of pumps, valves, or other process equipment via two dry contact closures
- Custom programming execution for up to ten steps in programmable flow modes
Note: DMF transducers should not be used for monitoring OXYGEN gas unless specifically cleaned and prepared. The controller will not operate with liquids.
Operating Conditions & Performance
The Series DMF operates within an ambient temperature range of 41 to 122°F (5 to 50°C). Specified flow ranges are for an equivalent flow of nitrogen at 70°F (21°C) @ 760 mm Hg. The maximum allowable pressure is 500 psig (34.5 bar), with a leak integrity rating of 1 x 10⁻⁹ sccs of helium and a maximum particulate size limit of 100 microns.
Performance specifications vary by operating conditions:
- Accuracy (Standard): ±1% FS including linearity between 59 to 77°F (15 to 25°C) and 10 to 60 psia (0.7 to 4 bar)
- Accuracy (Extended): ±2% FS from 32 to 122°F (0 to 50°C) and 5 to 150 psia (0.3 to 10 bar)
- Repeatability: ±0.15% of full-scale
- Response Time: 0.6 to 1.0 second to within ±2% of setpoint over 20% to 100% FS
The series requires a power supply of ±15 VDC with a maximum consumption of 13.5 watts.
Measurement Ranges
The Series DMF offers the following documented flow ranges:
- 0 to 10 sccm (DMF-41401)
- 0 to 20 sccm (DMF-41402)
- 0 to 50 sccm (DMF-41403)
- 0 to 100 sccm (DMF-41404)
- 0 to 200 sccm (DMF-41405)
- 0 to 500 sccm (DMF-41406)
- 0 to 1 L/min (DMF-41407)
- 0 to 2 L/min (DMF-41408)
- 0 to 5 L/min (DMF-41409)
- 0 to 15 L/min (DMF-41411)
- 0 to 30 L/min (DMF-41431)
- 0 to 50 L/min (DMF-41433)
- 0 to 100 L/min (DMF-41842)
Configuration Options
The Series DMF is configurable across several dimensions including process connections, output signals, and communication interfaces. The series supports an auto tune function to optimize control response for a specific gas under actual process conditions.
Process Connections & Dimensions
- Flow rates ≤50 L/m: 1/4" compression fitting; Overall dimensions: 6 1/4 [157.23] x 5 1/4 [133.86] x 1 1/2 [38.10]
- Flow rates ≥60 L/m: 3/8" compression fitting; Overall dimensions: 6-5/8 [167.13] x 5 5/8 or 5 7/8* [143.51] x 1 7/8 [47.75]
Outputs & Communication
- Analog Output: Linear 0-5 VDC (2000 Ω min. load impedance) or 0-10 VDC (4000 Ω min. load impedance)
- Digital Interface: RS-485 electrical connection
- Analog Mode Reference Input: 0-5 VDC reference input available for analog mode operation
- Communication Parameters (RS-232/RS-485): Baud rate 9600, Data bits 8, Stop bit 1, Parity NON
Accessories & Options
The series supports the following accessory options:
- Model DMF-110P: 110V power supply with 25-pin connector
- Model DMF-220PE: 220V power supply with 25-pin connector
- Model DMF-CBL1: 6' cable with branch to separate power supply
- Model DMF-CBL2: 6' cable with branch to computer port
- Dwyer SDPROC accessory Command Modules
Safety & Approvals
- Certifications: CE Compliance (CE)
- Attitude Sensitivity: ±15°; gas flow path must be horizontal within these limits
Key Product Differences
The Series DMF is distinguished by its model number, which indicates the specific flow range and configuration. Model numbers follow the format DMF-, such as DMF-41403 or DMF-41842.
- Housing Size Variation: Units are physically differentiated by size based on flow capacity, with larger housings required for flows ≥ 50 L/M compared to those ≤ 15 L/M.
- Connection Sizing: Process connections vary between 1/4" and 3/8" compression fittings depending on the selected flow range (≤50 L/m vs. ≥60 L/m).