Australia +61-2-4272 2055 | Welcome to our new website, found an issue or bug? Please report it here
LCFL
0.75 in to 1 in Diameter, Threaded, Miniature Inline Load Cells
0.75인치에서 1인치 직경, 나사산형, 소형 인라인 하중 셀
Models In Stock
- 全ステンレス鋼構造
- 5点校正 NISTトレーサブル付属
- 自動化用途向けの小型サイズ
- 59 kOhmシャント校正データ付属
LCFL
From
$
1,235.15
Models In Stock
Product Overview
- 5点校正 0%、50%、100%、50%、0%(張力)
- ブリッジ抵抗 350 Ω
- 校正オプション 5点NIST
- 電気接続 ケーブル
- エンクロージャーの定格 IP54
- 力タイプ 圧縮, 引張
- フルスケール振れ 0.003 in
- ロードセルタイプ インライン
- 材料 ステンレス鋼
- 動作温度(最高) 121 °C
- 動作温度(最低) -53 °C
- 過負荷、最大 300% FS
- プロセス温度(最高) 71 °C
- プロセス温度(最低) 16 °C
- 安全過負荷 150% FS
- シリーズID LCFL
- 熱スパン効果 ± 0.009% rdg/°C
- 熱ゼロ点効果 0.009% FSO/°C
- 配線/コネクタテーブル 緑:(-) 出力;白:(+) 出力;黒:(-) 入力;赤:(+) 入力
- ゼロ点/バランス誤差 ± 2%
Supported Applications
The Omega LCFL/LCMFL series comprises subminiature inline load cells designed for precision industrial applications requiring highly accurate readings. These tension link load cells measure either tension or compression loads and feature male thread studs for direct load attachment.
Operating Conditions & Performance
The series operates within an ambient temperature range of -53 to 121°C (-65 to 250°F) with an IP54 enclosure rating. Measurement ranges span from 0-2.2 lb (10 N) up to 0-100 lb (500 N). Performance specifications include a non-linearity of ±0.50% FSO, hysteresis of ±0.50% FSO, and repeatability of ±0.20% FSO.
Electrical Specifications
- Excitation Voltage: 5 Vdc for capacities ≤10 lb/50 N; 10 Vdc for ≥25 lb/100 N.
- Output Signal (Sensitivity): 1 mV/V (nom.) for 2.2 lb/10 N capacity; 2 mV/V (nom.) for capacities ≥5 lb/20 N.
- Load Resistance: 350 Ω minimum.
- Cable Connection: 1.5 m (5') 4-conductor, shielded PTFE cable with compensation board.
Configuration Options
The LCFL/LCMFL series is constructed from stainless steel and available in two primary diameters: 19 mm (0.75") for lower capacities and 25.4 mm (1") for higher capacities. The exclusive internal design provides superior long-term stability and minimizes the effects of small off-axis loads.
Process Connections & Accessories
The load cells feature male thread studs compatible with specific female rod end accessories:
- LCPF ≤10 lb models: Compatible with REC-006F (6-32 UNC female rod end).
- LCFL ≥25 lb models: Compatible with REC-010F (10-32 UNF female rod end).
- LCMFL ≥100 N models: Compatible with MREC-M6F (M6 x 1.00 female rod end).
Certifications & Calibration
The series carries RoHS compliance and includes a complete 5-point NIST-traceable calibration along with 59 kΩ shunt data.
Key Product Differences
Variants are distinguished by capacity, unit system (lb or N), and physical dimensions. The LCFL model numbers correspond to pound capacities ranging from 1KG/2.2 lb up to 100 lb. The LCMFL model numbers correspond to Newton capacities ranging from 10N up to 500N.
Dimensional Differences by Capacity
- Capacities 10 to 50 N (2.2 to 10 lb): Diameter A is 19.1 mm (0.75"); Length B is 10.1 mm (0.40).
- Capacities 100 to 500 N (25 to 100 lb): Diameter A is 25.4 mm (1.00); Length B is 9.9 mm (0.39).
Accessories
meters/controllers
1/8 DIN Thermocouple and RTD Panel Meter with Large, Selectable Color Display
$521.47 / each
0 In Stock
High Performance Strain gauge Meter, High Resolution 6-Digit Display
$1,116.55 / each
0 In Stock