Models In Stock
  • -18 to 538°C (0 to 1000°F) Temperature Range
  • Adjustable Emissivity from 0.1 to 1.0
  • 5 Different Analog Output Models
  • LED Display Model Available
;
OS100E
From C$ 583.74
Models In Stock
RS232 Output IR Sensor with Optional Display OS100E OS100E
loading all models
Product Overview
  • Accuracy ± 2 %
  • Air Flow rate 1 CFM
  • Alarm Deadband 5.5°C (10°F)
  • Alarm Setpoint Adjustable, 0 to 100%
  • Cable Length 6 ft
  • Control Output Open drain
  • Data Interface RS232
  • Data Interface Note Serial RS232, 2-way
  • Emissivity, Max 1
  • Emissivity, Min 0.1
  • Emissivity Note 0.1 to 1.00, adjustable
  • Enclosure Ratings IP65, NEMA Type 4
  • Field of view 6:1
  • Field of View Note 6:1 (distance/ spot size)
  • Housing Height 30.5 mm
  • Housing Length 115.3 mm
  • Housing Material Aluminum
  • Housing Width 65.5 mm
  • Laser Output false
  • Operating Temperature, Min 0 °C
  • Process Temperature, Max 538 °C
  • Process Temperature, Min -18 °C
  • Relative Humidity, Max 0.95
  • Relative Humidity Note Less than 95% RH, non-condensing
  • Repeatability ± 1%
  • Sensor Diameter 25.4 mm
  • Sensor Length 63.5 mm
  • Series ID OS100E
  • Spectral Response, Max 14 μm
  • Spectral Response, Min 5 μm
  • Supply Voltage 12 to 24 Vdc
  • Thermal shock About 30 minutes for 25°C (77°F) abrupt ambient
  • Warm-Up Period, Max 3 m
  • Warm-Up Period, Min 0 m
  • Water Flow Rate 0.25 GPM
  • Water Flow Rate Note 0.25 GPM, room temperature
  • Weight 272 g

Supported Applications

The OMEGA OS100E Series miniature infrared transmitters provide non-contact temperature measurement across an industrial range of -18 to 538°C (0 to 1000°F). Each unit pairs a remotely mounted infrared sensor head with a high-performance, microprocessor-based signal conditioner, so the small sensor head can be placed in confined, hard-to-reach places and harsh environments while the transmitter is mounted where it is convenient to wire and read.

Typical uses take advantage of the remote head, the analog and RS232 outputs, and the optional laser sighting:

  • Fixed-point process temperature monitoring in tight or hostile locations.
  • Integration with meters, chart recorders and PLCs through a choice of analog outputs.
  • PC-based configuration and readout over the RS232 interface.
  • Targeting assistance using the OS100-LS laser sighting accessory.

This product is not intended for medical use or use on humans. All connections should be made with a shielded cable, 24 AWG stranded wire rated 300V, 105°C (221°F), PVC insulation.

Operating Conditions & Performance

The transmitter measures -18 to 538°C (0 to 1000°F) with an optical field of view of 6:1 (distance to spot size) and a spectral response of 5 to 14 microns. Accuracy, referenced at 22°C (72°F) ambient and emissivity of 0.95 or greater, is ±2% rdg or 2.2°C (4°F), whichever is greater, with repeatability of ±1% rdg. Response time is 100 ms (0 to 63% of final value) and emissivity is adjustable from 0.1 to 1.00.

Power is 12 to 24 Vdc @ 150 mA, with overload protection of 500 mA on the family supply requirement. Minimum load resistance is 1 kΩ for the 0 to 5 Vdc output and 2 kΩ for the 0 to 10 Vdc output.

The housing is NEMA 4 (IP65) die-cast aluminium. Main housing dimensions are 65.5 W x 30.5 D x 115.3 mm L (2.58 x 1.2 x 4.54 inch), the sensor head is 25.4 mm (1 inch) diameter and 63.5 mm (2.5 inch) long, and the unit weighs 272 g (0.6 lb). Operating limits differ by section:

  • Main transmitter ambient: 0 to 50°C (32 to 122°F).
  • Sensor head: 0 to 70°C (32 to 158°F).
  • Sensor head, HT model: 0 to 85°C (32 to 185°F).
  • Sensor head with OS100-WC water cooling jacket: 0 to 200°C (32 to 392°F).

Operating relative humidity is less than 95% RH, non-condensing. The series is CE marked and, with the optional laser, complies with FDA 21 CFR 1040.10 as a Class II laser product and European Class 2 per EN60825-1/11.2001; maximum laser optical power is less than 1 mW @ 25°C (77°F).

Configuration Options

Model identity follows OS100E - output - display - temperature. Two base platforms set the display capability:

  • OS101E transmitters provide the measurement and outputs without a local display.
  • OS102E transmitters add a 4-digit LED display that is switchable between °C and °F.

Output options

The output suffix selects the electrical interface:

  • OS101E-MV — 1 mV/°C or °F output.
  • OS101E-V1 — 0 to 5 Vdc output.
  • OS101E-V2 — 0 to 10 Vdc output.
  • OS101E-MA — 4 to 20 mA output.
  • OS101E-K — Type K thermocouple output.

High temperature heads

An HT suffix denotes the high temperature sensor head, which extends the head rating from 0 to 70°C (32 to 158°F) up to 0 to 85°C (32 to 185°F). HT versions include OS101E-MA-HT and OS101E-V2-HT. Where still higher head exposure is required, the OS100-WC water cooling jacket allows sensor-head operation up to 0 to 200°C (32 to 392°F).

Key Product Differences

OS101E transmitters (no display)

  • OS101E-MV — 1 mV/°C or °F output.
  • OS101E-V1 — 0 to 5 Vdc output.
  • OS101E-V2 — 0 to 10 Vdc output.
  • OS101E-MA — 4 to 20 mA output.
  • OS101E-K — Type K thermocouple output.
  • High temperature heads: OS101E-MV-HT, OS101E-V1-HT, OS101E-V2-HT, OS101E-MA-HT, OS101E-K-HT.

OS102E transmitters (with LED display)

  • OS102E-MV — 1 mV/°C or °F output and LED display.
  • OS102E-V1 — 0 to 5 Vdc output and LED display.
  • OS102E-V2 — 0 to 10 Vdc output and LED display.
  • OS102E-MA — 4 to 20 mA output and LED display.

Accessories

  • OS100-MB — mounting bracket.
  • OS100-DR — DIN rail mounting adaptor.
  • OS100-AP — air purge collar.
  • OS100-WC — water cooling jacket, up to 200°C.
  • OS100-LS — laser sighting accessory.
  • OS100-CA15FT — sensor head extension cable, 4.6 m (15').
  • OS100-CA25FT — sensor head extension cable, 7.6 m (25').
  • TX8-100 — power/output cable, 30 m (100').
  • PSR-24S — regulated power supply, US plug, 90 to 264 Vac input, 24 Vdc output, 400 mA, screw terminals, UL.
  • PSU-93 — unregulated power supply, 16 to 23 Vdc, 300 mA max, screw terminal.

Accessories

accessories

AIR PURGE COLLAR
C$86.80 / each
6 In Stock
LASER SIGHTING ACCESSORY
C$508.59 / each
0 In Stock
WATER COOLING JACKET
C$508.59 / each
0 In Stock

cables

SENSORHEAD EXTENSION CABLE 15'
C$116.69 / each
0 In Stock
SENSORHEAD EXTENSION CABLE 25'
C$150.22 / each
0 In Stock
SENSORHEAD EXTENSION CABLE 35'
C$169.56 / each
0 In Stock
SENSOR HEAD EXTENSION CABLE 6'
C$71.46 / each
0 In Stock
SENSORHEAD EXTENSION CABLE 50'
C$285.79 / each
0 In Stock
Power / Output Cable for OS100
C$282.31 / each
3 In Stock

installation hardware

MOUNTING BRACKET
C$58.30 / each
1 In Stock
DIN RAIL MOUNTING ADAPTOR
C$71.46 / each
0 In Stock
Rated 5 out of 5 by from Easy to install, Super Display, Great unit Great unit over all if you need to monitor a temp in real time, additionally they are able to be calibrated/certified. Super Display, Large Clear numerals. Easy to install, takes minutes, Hugely adaptable to your needs.
Date published: 2021-01-21
Rated 5 out of 5 by from Product is great. We have been using these compact transmitters in multiple automation applications and have been impressed with their accuracy and reliability. Overall great option for measuring temperature in industrial applications.
Date published: 2023-02-06
Rated 1 out of 5 by from Failed The replacement product failed right out of the box.
Date published: 2020-10-26
Rated 4 out of 5 by from Good sensor and detection We installed the sensor in wafer oven and it is working very well, but is very sensitive.
Date published: 2017-03-27
  • y_2026, m_8, d_5, h_10
  • bvseo_bulk, prod_bvrr, vn_bulk_3.0.48
  • cp_1, bvpage1
  • co_hasreviews, tv_0, tr_4
  • loc_en_CA, sid_OS101E-K, prod, sort_[SortEntry(order=HELPFULNESS, direction=DESCENDING), SortEntry(order=POSITIVE_FEEDBACK, direction=DESCENDING), SortEntry(order=SUBMISSION_TIME, direction=DESCENDING)]
  • clientName_omega
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getReviews, 4ms
  • REVIEWS, PRODUCT

Does OS102E-MA contain Mercury?

Asked by: Mike2222
Thank you for your inquiry. We believe the best assistance would come from speaking to us directly at 888-826-6342 ask for the Temperature Department Mon. – Fri. (HOURS 8:30AM - 5:30PM EST).
Answered by: Application Engineer CB
Date published: 2023-12-21

The manual refers to a serial bus interface and an installation of the software with a CD. Is an interface with a USB available ? Also is an alternative emthod of installing the associated software available ?

Asked by: Flyingcar1
Thank you for the inquiry. You would need to use an RS232 to USB adapter. Software can be downloaded from this product page under "Manuals and Downloads". We do not currently offer the RS232 to USB adapter for this model. Best regards OMEGA
Answered by: NorwalkAE_RS
Date published: 2023-12-24

What is the size of the mounting nut supplied on the sensor head

Asked by: Mike2222
Hi Mike, Thank you for the inquiry. Mounting nut is 3/4-16 UNF. Best regards OMEGA
Answered by: NorwalkAE_RS
Date published: 2022-10-05
  • y_2026, m_8, d_5, h_10CST
  • bvseo_bulk, prod_bvqa, vn_bulk_3.0.48
  • cp_1, bvpage1
  • co_hasquestionsanswers, tq_3
  • loc_en_CA, sid_OS101E-K, prod, sort_[SortEntry(order=NUM_ANSWERS, direction=DESCENDING)]
  • clientName_omega
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getContent, 35ms
  • QUESTIONS, PRODUCT
en-CA
en_CA
Save Configuration