1-800-663-4209 | Welcome to our new website, found an issue or bug? Please report it here
								LCCA
Corrosion Resistant S-Beam Load Cells
			Models In Stock
	- Environmentally Protected for Washdown Applications
 - Corrosion Resistant
 - Calibration Certificate Supplied
 - 0.25% Interchangeable
 
LCCA
					From
					C$
					877.39
				
						Models In Stock
				
			
		    Product Overview
	- Accuracy ± 0.037%
 - Bridge Resistance 350 Ω
 - Cable Length 20 ft
 - Calibration Option NIST
 - Creep in 20 min 0.0003
 - Electrical Connection Cable
 - Electrical Output 3 mV/V
 - Force Type Compression, Tension
 - Hysteresis 0.0002
 - Interchangeability 0.0025
 - Load Cell Type S-beam
 - Materials Stainless Steel
 - Operating Temperature, Max 66 °C
 - Operating Temperature, Min -18 °C
 - Overload, Max 300% FS
 - Process Temperature, Max 66 °C
 - Process Temperature, Min -18 °C
 - Repeatability 0.0001
 - Safe Overload 150% FS
 - Supply Power Note 10 Vdc, 15 Vdc maximum
 - Supply Voltage 10 Vdc
 - Thermal Span Effect 0.0008% rdg/°F
 - Thermal Zero Effect 0.0015% FS/°F
 - Wire Gauge 22 AWG
 - Wiring/Connector Table Green: (+) Output; White: (-) Output; Black: (-) Input; Red: (+) Input
 - Zero/Balance Error 0.01
 
	LCCA-Series load cells with 3 mV/V output, 0.037% FS accuracy, and nickel-plated carbon steel construction. Operates 0–150°F. Includes 20 ft shielded cable. Handles up to 300% overload.
Show Ratings & Reviews
 
			
	
	
	
        
            Rated 5 out of
            5
         by
        Anonymous from
        Wokrs Perfectly
        Exactly what we needed.  We had to wait because it was backordered but it works perfectly.
        
    Date published: 2023-12-27
        
    
        
            Rated 5 out of
            5
         by
        Tbending from
        Nice little load cell!
        Well built load cell. Improved heavy gage wire. Great for everyday applications.
        
Date published: 2022-03-30
        
    What is the response time of the LCCA-50 load cell?
            Response time to a load change is 1 to 2 milliseconds
            
            
    Date published: 2021-08-27
        What you mean with the .25% Interchangeable?
            The 0.25% interchangeability spec refers to the full-scale output of the load cell. The S load cells have a nominal output spec of 3 mV/V (3 millivolts per volt of excitation) but every load cell will have some variation from the nominal value. In this case the output will always be within the range of 3 mV/V +/- 0.25% or between 2.9925 and 3.0075. The actual full-scale output will be provided on the calibration sheet that comes with each load cell. Thank you and please contact us again if you have any other questions.
            
            
    Date published: 2019-11-16
        How often do the load cells need to be calibrated?
            Thank you for your inquire.
We say 12 months after installation. Depending on usage and cycles 
Less usage longer between calibrations normally.
            
            
    Date published: 2021-10-12
        What's the spec on the threaded holes for connection on the LCCA-500?
            Thanks for connecting with Omega! The threads for LCCA-500 are ½-20. Please contact us anytime and view our LCCA Data Sheet for any other details you may require. https://assets.omega.com/pdf/test-and-measurement-equipment/load-and-force/load-cells/LCCA.pdf
            
            
    Date published: 2019-05-10