Skip to search Skip to main content Skip to navigation

Australia +61-2-4272 2055 | Welcome to our new website, found an issue or bug? Please report it here

We noticed you are in , please visit your local site by clicking the below link for regional offers and support.

Therm-Room

Thermistor Room Sensors

  • Space Temperature Sensing
  • Decorative Wall Sensor Applications
  • Office Buildings
  • Hospitals & Schools
  • Colleges
  • Commercial Buildings
  • OEM Opportunities
  • Roof Top Units
  • Supply/Discharge/Return/Mixed Air Temperatures
Therm-Room
From
Thermistor Room Sensors Therm-Room Therm-Room
loading all models
Product Overview
  • Applications Air and HVAC, Building and Maintenance, Commercial and Industrial, Medical, OEM, Office and Commercial
  • Curve Type NTC (Negative Temperature Coefficient)
  • Display Note LCD Display Supply Voltage: 9 V dc to 35 V dc / 24 V ac (50 Hz to 60 Hz); LCD Display Supply Current/VA: < 4 mA / 0.12 V A; LCD Display Accuracy: ±2 °F or ±2 °C at 21.5 °C (71 °F) typical; LCD Display Descriptor: °F (Fahrenheit) or °C (Celsius); Number of Digits: 3 1/2 Segment Display; LCD Display Life Expectancy: 50,000 hours minimum
  • Electrical Connection Screw Terminal
  • Enclosure Ratings UL94-HB
  • Number of Sensing Points 1
  • Operating Humidity 10 to 95% RH, non-condensing
  • Operating Temperature, Max 50 °C
  • Operating Temperature, Min 1.5 °C
  • Options Short Thermistor (Default); Field (Jumper) Selectable “Dry Contact” Closure (Separate Input); Short Set Point available upon request
  • Power Dissipation 3 mW / °C except: A/1.8K Series: 1 mW / °C A/10K-E1 Series: 2 mW / °C
  • Response Time 10 seconds nominal
  • Series ID Therm-Room
  • Set Point Tolerance ±10 % of range
  • Storage Temperature, Max 65 °C
  • Storage Temperature, Min -40 °C
  • Temperature Measurement Range 1.5 to 50°C
  • Tightening Torque 0.5 Nm minimum; 0.6 Nm maximum
  • Wire Gauge 26 AWG

Supported Applications

ACI Thermistor Room Series sensors are documented for indoor room temperature measurement and building-management-system connections. The source describes wall or junction-box mounting in areas with good air circulation.

Operating Conditions & Performance

The series uses thermistor sensing and screw terminal blocks. Source material documents four-way air-flow enclosure design and an optional foam pad for insulation from thermal drafts within a wall or wall surface.

Configuration Options

  • Documented configurations include beige or white enclosure styles, setpoint, after-hours override, communication-jack, and LCD options.
  • Available connection and mounting accessories include mounting plates, locking covers, thermostat guards, and the foam insulation pad.

Key Product Differences

Product variations differ by enclosure style, sensor configuration, display option, setpoint or override selection, and communication connection. LCD-option details remain option-specific.

en-AU
en_AU
Save Configuration