Australia +61-2-4272 2055 | Welcome to our new website, found an issue or bug? Please report it here
OP-F-2
Orifice plate flowmeter, 2" line size, 1.000" bore, 0.48 Beta, water capacity: 100" d.p. W/C, 35.34 GPM flow; air capacity: 100" d.p. W/C, 125.74 SCFM @ 14.7 psia, 202.03 SCFM @ 20 psig, 375.8 SCFM @ 100 psig; 3 lb.
Added to Your Shopping Cart
Configuration complete.
Please add to cart to keep it or exit the configuration
Please add to cart to keep it or exit the configuration
Failed to Save Configurations, Click on Configure Button Start Again
Product Specs
<< See all Product Models| Brand |
|
| Accuracy | ± 0.6 % |
| Air Flow, Max | 125.74 SCFM |
| Beta | 0.48 |
| Bore Size | 1 in |
| GrossWeightValue | 3 |
| Head Loss | 1 - Beta ratio² (eg: 1-0.72 = 1-0.49 = 51% of the d.p.) |
| Installation | Standard Flange, Any rating (orifice flanges not required) |
| Line Size | 2 in |
| Liquid Flow, Max | 35.34 GPM |
| Measurement Pressure Type | Gauge |
| Operating Temperature, Max | 200 °F |
| Operating Temperature, Min | -50 °F |
| Process Connection Size | 1/4 in |
| Process Connection Type | NPT Female |
| Series ID | Series-OP |
| Straight Run Requirements | 10 Diameters Upstream, 5 Diameters Downstream |
| Weight | 3 lb |
| Country of Origin | United States |
| See All Specs | |
PDFs & Manuals
Drawings