Skip to search Skip to main content Skip to navigation

India +91 8925807296 | Welcome to our new website, found an issue or bug? Please report it here

We noticed you are in , please visit your local site by clicking the below link for regional offers and support.

TJ36-XSIB

Rugged Thermocouple Transition Joint Probes with Silica Ceramic Insulation

Models In Stock
  • Inconel® Overbraided Silica Ceramic and Ceramic Insulated Lead Wire
  • Lead Wire Rated to 815°C (1500°)
  • 304 SS and Inconel® 600 sheaths. Additional Sheaths Available: 310 SS, 316 SS, 321 SS and Super OMEGACLAD™ XL
  • Manufactured with OMEGACLAD™ Compacted Mineral Insulation Cable for Long-Lasting, Drift-Free Performance in Harsh Conditions
TJ36-XSIB
From AUD 202.03
Models In Stock
Rugged Thermocouple Transition Joint Probes with Silica Ceramic Insulation TJ36-XSIB TJ36-XSIB
loading all models

Can't find the right model?

Use our custom configurator to fine tune your product

Product Overview
  • Insulation Note Super OMEGACLAD® XL Compacted Mineral Insulation Cable for Long-Lasting Performance in Harsh Conditions
  • Number of Connectors N/A
  • Process Temperature, Max 920 °C
  • Process Temperature, Min 0 °C
  • Series ID TJ36-XSIB
  • Temperature Sensor Type Thermocouple
  • Wire Termination Temperature, Max 815 °C
  • Wire Termination Temperature, Min 0 °C
  • Wire Type Stranded

Supported Applications

The Omega TJ36-XSiB series consists of rugged thermocouple transition joint probes designed for harsh conditions. These sensors utilize Super OMEGACLAD® XL Compacted Mineral Insulation Cable with Inconel® overbraided Nextel® lead wire and ceramic insulation, enabling operation in high-temperature environments up to 815°C (1500°F). The series is engineered for applications requiring robust temperature measurement where standard probes may fail due to thermal stress or mechanical strain.

Operating Conditions & Performance

The TJ36-XSiB series supports a broad range of upper temperature limits depending on the specific thermocouple type, sheath material, and diameter. The documented measurement ranges include:

  • K CHROMEGA®-ALOMEGA®: 899°C (1650°F) to 1204°C (2200°F)
  • J IRON-CONSTANTAN: 441°C (825°F) to 721°C (1330°F)
  • T COPPER-CONSTANTAN: 260°C (500°F) to 371°C (700°F)

Specific upper temperature guidelines vary by configuration. For example, K-type probes with a 304 SS sheath list an upper limit of 899°C (1650°F), while XL sheaths support up to 1204°C (2200°F). The series meets or exceeds Special Limit of Error (SLE) and EN 60584-2: Tolerance Class 1 standards. A spring strain relief is integrated into the design to prevent wire pinching at the transition joint.

Sheath Materials

  • 304 SS (Stainless Steel)
  • INC 600 (Inconel® 600)
  • XL (Super OMEGACLAD® XL Compacted Mineral Insulation Cable)

Configuration Options

The series offers extensive configurability across sheath diameters, junction types, probe lengths, and electrical terminations. The standard lead length is 1000 mm (40"). Probe stem lengths are available in stock at 150 mm (6"), 300 mm (12"), and 450 mm (18").

Sheath Diameters

  • 1.59 mm (1/16 in)
  • 3.18 mm (1/8 in)
  • 4.78 mm (3/16 in)
  • 6.35 mm (1/4 in)

Junction Types

The model number guide specifies junction types as:

  • (J) rounded
  • (E)xposed
  • (U)ngrounded

Grounded immersion probes are also available in the variant list.

Electrical Connections

The standard termination is stripped leads. Optional male plugs include:

  • Straight M8 plug (add "M8-S-M")
  • Straight M12 plug (add "M12-S-M")
  • Right-angled M8 plug (add "M8-R-M")
  • Right-angled M12 plug (add "M12-S-M")

A Probe Configurator is available for additional cold-end terminations, sheath materials, and lead wire options.

Key Product Differences

Variants within the TJ36-XSiB series are distinguished by thermocouple type (K, J, T), sheath material (304 SS, INC 600, XL), diameter code, junction configuration, and probe length. Model numbers follow the format: TJ36-----CC-XSiB. For example, a K-type probe with an Inconel® 600 sheath, 1/8 inch diameter, ungrounded junction, and 300 mm (12") length is designated as TJ36-CAIN-18U-12-CC-XSiB. The series includes both exposed air probes for ambient measurement and grounded/ungrounded immersion probes for process media.

en-IN
en_AU
Save Configuration