Australia +61-2-4272 2055 | Welcome to our new website, found an issue or bug? Please report it here
HHAQ-107-Meter
Handheld Volatile Organic Compound (VOC) Meter
Discontinued, no replacement
- Metal-Oxide Semi-Conductor Sensor within Vented Ball Housing Detects Ammonia, Toluene, Ethanol, Hydrogen Sulfide (H2S) and Cigarette Smoke
- Make Total VOC Concentration Measurements, Ambient Temperature, Relative Humidity (RH), Dew Point and Wet Bulb Temperatures
- Logs Up to 32,000 Data Points
- Powerful Data Logging Software
- Adjustable High VOC Concentration Audible Alarm
- Min/Max Memory (for All Measured Parameters) and Data Hold
- Separate Automated Procedures for VOC Zero Adjustment and Background Calibration
- Manually Off-Settable Temperature and RH Sensor Drift
- Large Backlit Dual-Readout LCD
- Tripod Mountable
HHAQ-107-Meter
From
AUD
1,290.52
Product Overview
- Additional Features 1 Sensor Longevity for Metal-oxide semiconductor - 5 years (typical)
- Air Quality Measurement 0 to 50 ppm
- Auto Power Off 15 minutes of front-panel inactivity (can be disabled)
- Battery Size and Type Alkaline AAA
- Data Logging 32,004 points
- Dew Point Temperature, Max 47 °C
- Dew Point Temperature, Min -73 °C
- Display Size 51 mm (2 in)
- Display Type Dual Readout LCD
- Height 25 mm
- Length 210 mm
- Number of Batteries 6
- Operating Humidity 0 to 95% RH
- Operating Temperature, Max 50 °C
- Operating Temperature, Min 0 °C
- Process Temperature, Max 50 °C
- Process Temperature, Min -10 °C
- Relative Humidity 10 to 90%
- Relative Humidity Accuracy ± 5% RH
- Relative Humidity Accuracy Note ±5% of reading at 25°C ; ±7% of reading elsewhere in range
- Relative Humidity Resolution 0.1% RH
- Resolution 0.01 ppm
- Sensor Type Metal-Oxide Semiconductor, RH Sensor Drift
- Series ID HHAQ-107-Meter
- Supply Power Note (6) “AAA” batteries (included) or included 110 Vac adaptor
- Temperature Accuracy ± 0.6 °C
- Temperature Resolution 0.1 °C
- Warm Up Time 10 minutes first use, 2 minutes thereafter
- Weight 204 g
- Wet Bulb Temperature, Max 48.2 °C
- Wet Bulb Temperature, Min -11 °C
- Width 60 mm
Supported Applications
The Omega HHAQ-107 is a handheld instrument designed for making ballpark measurements of mixed-gas volatile organic compound (VOC) levels as part of an indoor air quality (IAQ) maintenance program. It utilizes a metal-oxide semiconductor sensor within a vented ball housing to detect ammonia, toluene, ethanol, hydrogen sulfide (H2S), and cigarette smoke.
The device is intended for spot-checking concentrations of mixed-gas VOCs rather than precise single-gas measurements. In addition to total VOC concentration, the meter measures ambient temperature, relative humidity (RH), dew point, and wet bulb temperatures.
Operating Conditions & Performance
The HHAQ-107 operates within an ambient temperature range of 0 to 50°C (32 to 122°F) at 0 to 95% RH, non-condensing. The instrument features a large backlit dual-readout LCD with a 51 mm (2") diagonal display.
Performance specifications for the series include:
- VOC Measurement Range/Resolution: 0 to 50 ppm / 0.01 ppm
- VOC Warmup Time: 10 minutes first use, 2 minutes thereafter
- Temperature Measurement Accuracy/Resolution: ±0.6°C (1.2°F) / 0.1°
- RH Measurement Range: 10 to 90% RH
- RH Measurement Accuracy/Resolution: ±5% of reading at 25°C (77°F); ±7% of reading elsewhere in range / 0.1% RH
- Dew Point Measurement Range: -73 to 47°C (-99.2 to 118°F)
- Wet Bulb Measurement Range: -11 to 48.2°C (12.2 to 118.8°F)
The device includes an adjustable high VOC concentration audible alarm, min/max memory for all measured parameters, and a data hold function.
Data Logging & Power
- Capacity: Logs up to 32,004 points. The entire capacity can be devoted to VOC readings or divided one-third each among VOC, ambient temperature, and RH readings.
- Interface: USB cable included for connection to a PC-compatible data logging program on mini-disc.
- Power Source: (6) 'AAA' batteries (included) or included 110 Vac adaptor.
- Auto Power-Off Trigger: 15 minutes of front-panel inactivity (can be disabled).
Configuration Options
The HHAQ-107 series is offered as a single handheld configuration with the following documented capabilities and included accessories:
- Housing Material: Black and yellow plastic housing.
- Sensor Type/Longevity: Metal-oxide semiconductor / 5 years (typical).
- Data Logging Modes: Software supports four data logging modes, including starting and stopping recording without a PC.
- Calibration Features: Automated VOC zero adjustment procedure; manually offsettable temperature and RH sensor drift.
- Mechanical Mounting: Tripod mountable design.
The package includes the HHAQ-107 instrument, PC-compatible data logging program on mini-disc, USB cable, AC adaptor, soft pouch, (6) 'AAA' batteries, and operator's manual. Replacement parts include MN2400 replacement 'AAA' batteries (2 per pack, 3 packs needed).
Key Product Differences
The HHAQ-107 is the sole model in this series bundle. The device features a dual-readout LCD display and includes an automated VOC zero adjustment procedure to maintain sensor baseline.
PDFs & Manuals
Software & Drivers