India +91 8925807296 | Welcome to our new website, found an issue or bug? Please report it here
Series-S2
Budget Surface Mount Temp Sensor for Water, Steam, and Refrigerant Lines
- Low profile sensor can be taped or strapped to the outside of a pipe
- Ideal for applications where immersion wells are not feasible
Series-S2
From
AUD
134.15
Product Overview
- Applications HVAC
- Mounting Orientation Surface Mount
- Operating Temperature, Max 250 °F
- Operating Temperature, Min -40 °F
- Probe Diameter 0.25 in
- Probe Length 1 in
- Series ID Series-S2
- Sheath Material 304 Stainless Steel
Supported Applications
The Dwyer Series S2 Surface Mount Temperature Sensor provides a cost-effective and reliable solution for surface contact temperature measurement. The series is designed for conditioned water pipes, low pressure steam lines, or refrigerant lines. It serves as a low-profile sensor that can be taped or strapped to the outside of a pipe, making it suitable for applications where immersion wells are not feasible. Documented uses include heating or cooling loop line temperature monitoring and HVAC systems.
Operating Conditions & Performance
The Series S2 operates within an ambient and process temperature range of -40 to 250°F (-40 to 120°C). The sensor probe features a diameter of 1/4" (6.3 mm) and an overall length of 1" (25 mm), constructed from 304 Stainless Steel.
Accuracy specifications vary by the selected temperature element:
- Platinum RTD: ±0.1% @ 32°F (0°C), alpha 385 per DIN 43760
- Thermistor: ±0.5°C interchangeable @ 77°F (25°C)
Configuration Options
The series supports multiple configuration options for wire length and sensor type, defined by the model number guide: S2 - <WIRE LENGTH> - <TEMPERATURE SENSOR>. Electrical connections utilize 22 AWG 7/30 Stranded Etched Teflon® wires.
Wire Length Options:
- 1: 2 ft cable
- 6: 6 ft cable
- 10: 10 ft cable
- 20: 20 ft cable
Temperature Sensor Options:
- A: 10K NTC (TIII)
- B: 10K NTC (TII)
- C: 3K NTC
- D: Pt 100 (Available in 2 ft cable only)
- E: Pt 1000
- F: 20K NTC
Key Product Differences
Variants within the Series S2 differ primarily by wire length and sensor element type. The model number suffix indicates these selections; for example, an "S2-1D" denotes a 2 ft cable with a Pt 100 sensor. A specific constraint applies to the Pt 100 option (code D), which is available only in the 2 ft cable configuration.