Skip to search Skip to main content Skip to navigation

India +91 8925807296 | Welcome to our new website, found an issue or bug? Please report it here

We noticed you are in , please visit your local site by clicking the below link for regional offers and support.

PT-104A-DAQ-Module

4-Channel RTD Input DAQ Module with USB or Ethernet Interface

Models In Stock
  • Measures Temperature (RTDs), Resistance and Voltage
  • High Accuracy (0.01°C) and Resolution (0.001°C)
  • Powered by USB Port or Power-Over-Ethernet (PoE)
  • For Use with 2, 3 and 4-Wire Pt100 and Pt1000 RTD Sensors
PT-104A-DAQ-Module
From AUD 1,975.27
Models In Stock
4-Channel RTD Input DAQ Module with USB or Ethernet Interface PT-104A-DAQ-Module PT-104A-DAQ-Module
loading all models
Product Overview
  • Accuracy ± 0.002%
  • Conversion Rate 720 msec
  • Data Interface Ethernet, USB 2.0
  • Data Interface Note Ethernet Cable Length, Max: 100 m;Ethernet Port: Conforms to IEEE 802.3 10Base-T.; Compatible with 10/100/1000Base-T networks.; Conforms to IEEE 802.3af Power-over-Ethernet (PoE);;Supported Operating System: Microsoft Windows®XP SP2 / VISTA/7, Software Development Kit containing drivers and example code for C, C++, Excel and LabView.
  • Electrical Connection DIN 43650 C (solenoid valve)
  • Height 36 mm
  • Impedance Input >1 MΩ
  • Input Noise Voltage RMS: RTD: 0.01°C, Resistance: 10 ppm, Voltage:10 ppm
  • Input Type RTD, Voltage, Resistance
  • Input Type Note RTD: Pt100, Pt1000, 2, 3 and 4-Wire
  • Length 184 mm
  • Linearity RTD: 20 ppm, Resistance: 20 ppm, Voltage: 20 ppm
  • Number of Channels, Input Temperature: 4
  • Operating Temperature, Max 70 °C
  • Operating Temperature, Min 0 °C
  • Relative Humidity 20 to 90% RH
  • Resistance Measurement Range 0 to 375 Ω, 0 to 10 kΩ
  • Resolution RTD: 0.001°C, Resistance: 1 µΩ, Voltage: 0.156 µV
  • Series ID PT-104A-DAQ-Module
  • Software Logging Software
  • Supply Current Up to 200 mA
  • Supply Power Note Powered by USB or Ethernet: USB 1.1: 5V ±10% @ <100 mA, USB 2.0: 5V ±10% @ <200 mA, Ethernet: 48V ±20% @ <40 mA (<2W)
  • Supply Voltage 5 Vdc
  • Temperature Coefficient RTD: 5 ppm/°C, Resistance: 5 ppm/°C, Voltage:100 ppm/°C
  • Voltage Measurement Range 0 to 115 mV, 0 to 2.5V
  • Weight 500 g
  • Width 135 mm

Supported Applications

The Omega PT-104A is a four-channel, high-resolution temperature data acquisition module designed for use with Pt100 and Pt1000 RTD sensors. Beyond temperature measurement, the series supports resistance measurements in ranges of 0 to 375 Ω and 0 to 10 kΩ, as well as voltage inputs ranging from 0 to 115 mV or 0 to 2.5 V. The module is compatible with 2-wire, 3-wire, and 4-wire RTD sensor configurations, with 4-wire Pt100 sensors recommended for the highest accuracy.

The PT-104A facilitates data collection via Windows Logging Software or a provided Software Development Kit (SDK) containing drivers and example code for C, C++, Excel, and LabView. Up to 20 units of PT-104A modules can be connected simultaneously in various configurations.

Operating Conditions & Performance

The module operates within an ambient temperature range of 0 to 70°C (32 to 158°F). For stated accuracy, the environmental condition is specified as 20 to 30°C (68 to 86°F) with a relative humidity rating of 20 to 90% RH. The device features Class 'A' DIN Platinum Elements per IEC 751.

Performance specifications include:

  • Temperature Range: -200 to 800°C (-328 to 1472°F)
  • Resolution: 0.001°C for temperature; 1 μΩ and 0.156 μV for resistance/voltage
  • Accuracy @ 25°C: 0.01°C (temperature), 20 ppm (resistance), or 0.2% (voltage)
  • Linearity: 20 ppm
  • RMS Noise (Using Filter): 0.01°C for temperature; 10 ppm for resistance/voltage
  • Conversion Time Per Channel: 720 mS
  • Input Impedance: >>1 MΩ
  • Overvoltage Protection: ±30V

The response time is less than 75 milliseconds in water flowing at 3 feet per second.

Configuration Options

The PT-104A series offers flexible connectivity and power options through USB or Ethernet interfaces. The module can be powered via USB (USB 1.1: 5V ±10% @ <100 mA; USB 2.0: 5V ±10% @ <200 mA) or Power-Over-Ethernet (PoE). It conforms to IEEE 802.3af PoE standards and is compatible with 10/100/1000Base-T networks.

Key configurable features include:

  • Sensor Inputs: Supports Pt100 and Pt1000 RTDs in 2, 3, or 4-wire configurations via a 4-pin mini DIN connector
  • Data Interface: USB (conforms to USB 2.0 full-speed at 12 Mbps) or Ethernet (IEEE 802.3 10Base-T)
  • Software Support: Includes Windows Logging and Player Software for data visualization in spreadsheet or graph formats, plus an SDK
  • Physical Dimensions: 36 H x 135 W x 184 mm D (1.42 x 5.31 x 7.24") with a weight of 500 g (1.1 lb)

The standard package includes the PT-104A module, USB cable, Ethernet patch cable, four mating mini DIN screw terminal connectors, quick start guide, Windows software, and a complete operator's manual on CD.

Key Product Differences

The series is identified by model number PT-104A as the 4-channel RTD input data acquisition module. The device supports multiple operational modes including USB-only connections, USB-powered with Ethernet data transmission, and full Power-over-Ethernet configurations.

Accuracy specifications vary based on measurement type: temperature accuracy is quoted at 0.01°C for options marked in the specification table; resistance accuracy is 20 ppm; voltage accuracy is 0.2% (with a note that for the 115 mV range, accuracy may vary by 2%). The temperature coefficient is specified as 5 ppm/°C for standard ranges and 100 ppm/°C for specific conditions.

en-IN
en_AU